draft Static and Mobile Pressure Vessels (Unfired) (Amendment) Rules, 2018 Published

Reliability

In force — no superseding record on file.

Document text

2331 GI/2018 (1)

jftLVªh laö Mhö ,yö&33004@99 REGD. No. D. L.-33004/99

vlk/kj.k EXTRAORDINARY Hkkx II—[k.M 3—mi&[k.M (i) PART II—Section 3—Sub-section (i) izkf/dkj ls izdkf'kr PUBLISHED BY AUTHORITY la- 260] ubZ fnYyh] lkseokj] vizSy 23] 2018@ oS'kk[k 3] 1940
No. 260] NEW DELHI, MONDAY, APRIL 23, 2018/ VAISAKHA 3, 1940 वािण य वािण य वािण य वािण य और और और और उ ोग उ ोग उ ोग उ ोग मंालय मंालय मंालय मंालय (औ ोिगक औ ोिगक औ ोिगक औ ोिगक नीित नीित नीित नीित और और और और संवधन संवधन संवधन संवधन िवभाग िवभाग िवभाग िवभाग) अिधसूचना अिधसूचना अिधसूचना अिधसूचना नई द ली, 20 अ ैल, 2018 सा.का.िन. सा.का.िन. सा.का.िन. सा.का.िन. 388 388 388 388(अ (अ (अ (अ).— िथर और गितशील दाब पा (अ विलत) िनयम, 2016 के संशोधन का ाप, भारत के राजप, असाधारण, भाग-II, धारा 3, उप-धारा (i), म, भारत सरकार के वािण य और उ ोग मंालय (औ ोिगक नीित और संवध न िवभाग) क! अिधसूचना सं$ यांक सा.का.िन. 887(अ), तारीख 17 जुलाई, 2017 )ारा कािशत +कया गया था, िजसम उन सभी . यि/य0 से, िजनके उनसे भािवत होने क! संभावना थी, उस तारीख से िजसको अिधसूचना जनता को उपल2 ध करा दी गई थी, प3तालीस +दन क! अविध क! समाि5 के पूव आ7ेप और सुझाव आमंित +कए गए थे; और उ; त अिधसूचना जनता को तारीख 17 जुलाई, 2017 को उपल2 ध करा दी गई थी; और के< =ीय सरकार )ारा उ; त ाप िनयम0 के िवषय म जनता से ा> त आ7ेप0 और सुझाव0 पर स? यक प से िवचार कर िलया गया है; अतः अब, के< =ीय सरकार, िव फोटक अिधिनयम, 1884 (1884 का 4) क! धारा 5 और धारा 7 )ारा दA त शि/य0 का योग करते Bए िथर और गितशील दाब पा (अ विलत) िनयम, 2016 का और संशोधन करने के िलए िन? निलिखत िनयम बनाती है, अथा त्-
1.
.
.
.

धिनयम, 1884 (1884 का 4) क! धारा 5 और धारा 7 )ारा दA त शि/य0 का योग करते Bए िथर और गितशील दाब पा (अ विलत) िनयम, 2016 का और संशोधन करने के िलए िन? निलिखत िनयम बनाती है, अथा त्-
1.
.
.
. संि त संि त संि त संि त नाम और ारंभ नाम और ारंभ नाम और ारंभ नाम और ारंभ (1) इन िनयम0 का संि7> त नाम िथर और गितशील दाब पा (अ विलत) (संशोधन) िनयम, 2018 है। (2) ये राजप म काशन क! तारीख को वृE ह0गे।

2
THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]

  1. िथर और गितशील दाब पा (अ विलत) िनयम, 2016 (िजसे इसम इसके पH चात् उ; त िनयम कहा गया है) के िनयम 2 म,-
    (क) खJ ड (iii) के पH चात्, िन? निलिखत खJ ड अंतः थािपत +कया जाएगा, अथा त्– ‘(iiiक) “ऑटो एलएनजी” से ऑटोमोOटव Pधन के िलए बनी =िवत ाकृितक गैस (एलएनजी) अिभेत है;’; (ख) खJ ड (iv) के पH चात्, िन? निलिखत खJ ड अंतः थािपत +कया जाएगा, , अथा त्:– ‘(ivक) “ऑटो एलएनजी पOर7ेपण टेशन” से मोटर यान0 म ऑटोमोOटव Pधन के प म ऑटो एलएनजी के भJडारण और पOर7ेपण के िलए यु; त कोई पOरसर अिभेत है;’; (ग) खJ ड (v) के पH चात्, िन? निलिखत खJ ड अंतः थािपत +कया जाएगा, अथा त्– ‘(vक) “ऑटो एलएनजी या ऑटो एलसीएनजी पOर7ेपी ितR ठापनकता ” से ऑटो एलएनजी या ऑटो एलसीएनजी पOर7ेपण टेशन के ितR ठापन और ब<धन के िलए मु$य िनयंक )ारा मा<यताा> त और अनुसूची IV म िविनUद V अह ता और अनुभव ा5 क?पनी अिभेत है;’; (घ) खJ ड (xiv) म, “थमWसाइफन ट3क शािमल ह3 और िजसम” श2 द0 के  थान पर “थमWसाइफन ट3क सिहत” श2 द रख जाएंगे;

िनयंक )ारा मा<यताा> त और अनुसूची IV म िविनUद V अह ता और अनुभव ा5 क?पनी अिभेत है;’; (घ) खJ ड (xiv) म, “थमWसाइफन ट3क शािमल ह3 और िजसम” श2 द0 के  थान पर “थमWसाइफन ट3क सिहत” श2 द रख जाएंगे; (ङ) खJ ड (xv) म, “=िवत पेXोिलयम गैस (एल.पी.जी.) आधान” श2 द0 के पH चात् “अथवा =िवत ाकृितक गैस (एल.एन.जी.) आधान” श2 द अंतः थािपत +कए जाएंगे। (च) खJ ड(xviii) के  थान पर, िन? निलिखत खJ ड अंतः थािपत +कया जाएगा,अथा त्ः- “(xviii) “िवतरक (िडपे<सर)” से =िवत पेXोिलयम गैस पOर7ेपी टेशन या =िवत ाकृितक गैस पOर7ेपी टेशन म, यथािथित मोटर यान0 म ऑटोमोOटव Pधन के प म =िवत पेXोिलयम गैस या =िवत ाकृितक गैस के पOर7ेपण के िलए अिधYािपत उप कर अिभेत है;”; (छ) खJ ड (xxxi(क) के  थान पर िन? निलिखत खJ ड रख जाएंगे, अथा त्– “[(xxxi(क)] "=िवत ाकृितक गैस (एलएनजी)" से Zायोजेिनक =िवत अवथा म एक =व अिभेत है जो मु$य प से मीथेन से बना है; “[(xxxi(ख)] )“एलसीएनजी” से Pधन भरण टेशन म एलएनजी से पंप और वाRपीकरण )ारा सीएनजी का उAपादन अिभेत है’। 3. उ; त िनयम म िनयम 29 के  थान पर, िन? निलिखत िनयम रखा जाएगा, अथा त्ः– “29. ऑटो एलपीजी या ऑटो एलएनजी पOर7ेपण टेशन के िलए िवतरक (िडपे<सर).-ऑटो एलपीजी या ऑटो एलएनजी पOर7ेपण टेशन0 म मोटर वाहन0 म ऑटो एलपीजी या ऑटो एलएनजी के पOर7ेपण के िलए उपयोग +कए जाने वाले िडपे<स और उनसे जुड़े +फ[टंग, यथािथित, िनयम0 क! अनुसूची II या अनुसूची IV म दी गई अपे7ा\ के अनुप अिभकि]पत, िन^म त, परीि7त और अनुरि7त ह0गी और मु$य िनयंक )ारा िलिखत म अनुमो+दत कार क! ह0गी।” 4. उ; त िनयम के िनयम 30 के  थान पर, िन? निलिखत िनयम अंतः थािपत +कया जाएगा, अथा त्:- “30.

\ के अनुप अिभकि]पत, िन^म त, परीि7त और अनुरि7त ह0गी और मु$य िनयंक )ारा िलिखत म अनुमो+दत कार क! ह0गी।” 4. उ; त िनयम के िनयम 30 के  थान पर, िन? निलिखत िनयम अंतः थािपत +कया जाएगा, अथा त्:- “30. ऑटो एलपीजी या ऑटो एलएनजी पOर7ेपण टेशन म मोटर यान0 के इंधन ट3क भरने और ट3क-Xक0 के उतराई के िलए िवशेष उपाबंध. – (1) यान चालू अवथा म होने क! िथित म मोटर यान के इंधन ट3क म ऑटो एलपीजी या ऑटो एलएनजी नह_ भरा जाएगा।

(2) ट3क-Xक से भJडारण पा0 म ऑटो एलपीजी या ऑटो एलएनजी के उतराई के दौरान मोटर यान0 म ऑटो एलपीजी या ऑटो एलएनजी के पOर7ेपण का काय नह_ +कया जाएगा।”

¹Hkkx IIµ[k.M 3(i)º Hkkjr dk jkti=k % vlk/kj.k 3 5. उ; त िनयम के िनयम 49 म, उप-िनयम (4) म श2 द0 और अंक0 “एलएस-1ख” के पH चात् “एलएस-1ग” श2 द और अंक अंतः थािपत +कए जाएंगे।
6. उ; त िनयम0 के िनयम 50 म, उप-िनयम (i) के खJ ड (क) म “ऑटो एलपीजी के भJडारण और पOर7ेपण” श2 द0 और अ7र0 के पH चात् “और प एलएस-1ग म ऑटो एलएनजी के मोटर Pधन के प म भJडारण और िवतरण के िलए हो” श2 द, अ7र और अंक अंतः थािपत +कए जाएंगे।
7. उ; त िनयम0 के िनयम 51 म, उप-िनयम (1) म “एलएस-1ख” श2 द0 और अंक0 के पH चात् “या एलएस-1ग” श2 द और अंक अंतः थािपत +कए जाएंगे।
8. उ; त िनयम0 के िनयम म िनयम 55 म, उप-िनयम (2) म “एलएस-1ख” श2 द0 और अंक0 के पH चात् श2 द और अंक “एलएस-1ग” अंतः थािपत +कए जाएंगे।
9. उ; त िनयम0 क!, अनुसूची 1 म,-
(क) सारणी के भाग क म, Z.सं.3” क! पंि/ और इससे संबंिधत िविYय0 को “Z.सं.4” के प म पुनःसं$ यां+कत +कया जाएगा और इस कार पुनःसं$ यां+कत Z.सं. 4 से पहले िन? निलिखत पंि/ को अंतः थािपत +कया जाएगा, अथा त्:-
“3.

भाग क म, Z.सं.3” क! पंि/ और इससे संबंिधत िविYय0 को “Z.सं.4” के प म पुनःसं$ यां+कत +कया जाएगा और इस कार पुनःसं$ यां+कत Z.सं. 4 से पहले िन? निलिखत पंि/ को अंतः थािपत +कया जाएगा, अथा त्:-
“3. एल एस-1ग मोटर यान0 म ऑटोमोOटव Pधन के प म ऑटो एलएनजी के पOर7ेपण के िलए ऑटो एलएनजी का भJडारण और पOर7ेपण और/ या एलसीएनजी पOर7ेपण के संबंध म एलएनजी का भJडारण।
मु$ य िनयंक या उनके )ारा ािधकृत िनयंक यथावत जैसा +क अनुgि5 प एलएस-1क म है”; (ख) भाग ख के  थान पर, िन? निलिखत भाग रखा जाएगा, अथा त्:- “ख : अनुि अनुि अनुि अनुि फस फस फस फस सेसेसेसे िभ न िभ न िभ न िभ न फस फस फस फस
. . . . सं. सं. सं. सं.

योजन योजन योजन योजन फस( फस( फस( फस(#.म) .म) .म) .म) 1. िनयम 4(3)(i)और (ii) के अधीन दाबपा, वािRप और +फ[टंग िविनमा ण हेतु दुकान अनुमोदन या नवीकरण के िलए अनुमोदन
5000/-ितवष 2 िनयम 4(3)(iii) के अधीन दाबपा, वािRप और +फ[टंग के अिभक]पना (िडजाइन) आरेखण का अनुमोदन
2500/- 3. िनयम 4(5) के अधीन दाबपा का आयात
5000/- 4. िनयम 6 के अधीन दाबपा0 क! मर?मत
2500/- 5. िनयम 12 के अधीन स7म iि/ / िनरी7क के प म मा<यता/ पुनवjधीकरण
5000/- ितवष 6. िनयम 35(2) के अधीन संपीिड़त गैस के पOरवहन के िलए यान के माउ[टंग आरेखण का अनुमोदन 2000/- 7. िनयम 46 के अधीन पा0 और पOरसर के िविनदkश और योजना का पूवा नुमोदन 2000/- 8. िनयम 49(3) के अधीन अनुgि5 क! मािणत ित जारी करने के िलए 1000/- 9. िनयम 53(2) के अधीन अनुg5 पOरसर म Aयावत न हेतु पूवा नुमोदन
2000/- 10. िनयम 54(1) के अधीन अनुgि5 का संशोधन 1000/- 11. िनयम 54(2) के अधीन अनुgि5 का अंतरण
1000/- 12.

करने के िलए 1000/- 9. िनयम 53(2) के अधीन अनुg5 पOरसर म Aयावत न हेतु पूवा नुमोदन
2000/- 10. िनयम 54(1) के अधीन अनुgि5 का संशोधन 1000/- 11. िनयम 54(2) के अधीन अनुgि5 का अंतरण
1000/- 12. िनयम 60(2) के अधीन अनुgि5धारी क! मृAयु या असमथ ता क! दशा म नई अनुgि5 जारी करना 1000/- 13. िनयम 61 के अधीन अनुgि5 क! अनुिलिप जारी करना 1000/- 14. सं थापक/ ऑपरेटर के िलए अनुसूची- II और अनुसूची IV म यथा उि]लिखत, मा< यता जारी करना/ नवीकरण करना 5000/- ितवष

4
[PART II—SEC. 3(i)]

उ; त िनयम म, अनुसूची 2 के, खJ ड (ड) के पH चात् िन? निलिखत खJ ड अंतः थािपत +कया जाएगा, अथा त्:-

“(डअ) ऑटो एलपीजी ऑपरेटर को मा<यता जारी करने क! +Zया:- (i) +कसी भी संगठन को ऑटो एलपीजी ऑपरेटर के प म मा<यता ा5 करने के िलए अपना आवेदन िजसम बंधन और ऑटो एलपीजी िवतरण टेशन के संचालन के 7े म अपने अनुभव के संबंध म कंपनी का Aयय-प, मु$य िवफोटक िनयंक को तुत करना होगा।
(ii) Aयेक आवेदन के साथ अनुसूची-। के भाग ख म यथा िविनUद R ट संवी7ा फ!स संलl होनी चािहए।
(iii) मु$य िनयंक आवेदन क! ाि5 तारीख से न2 बे +दन क! अविध के भीतर,या तो- (क) थम दृVया, ऑटो एलपीजी पOर7ेपन  टेशन ऑपरेटर के प म, आवेदक को मा<यता दान करने के िलए, स7मता और iावसाियक आचार नीित के स?ब<ध म वयं संतोषद होने पर, आवेदक का तकनीक! और iावहाOरक gान और स7मता िनधा रण करने के िलए मु$य िनयंक )ारा नामिनUद R ट अिधकाOरय0 के दल )ारा सा7ाAकार के िलए आवेदक को उसके तकनीक! दल के साथ बुलाया जाएगा; या

(ख) य+द थम दृVया आवेदक मा<यता क! अपे7ा\ के अनुकूल नह_ पाया जाता है तो आवेदन को कारण0 सिहत अवीकार कर +दया जाएगा;

ल )ारा सा7ाAकार के िलए आवेदक को उसके तकनीक! दल के साथ बुलाया जाएगा; या

(ख) य+द थम दृVया आवेदक मा<यता क! अपे7ा\ के अनुकूल नह_ पाया जाता है तो आवेदन को कारण0 सिहत अवीकार कर +दया जाएगा; या (iv) (क) य+द इस िनयम के अधीन संचािलत सा7ाAकार म, आवेदक म, मा<यता के िलए पया 5 gान और स7मता पाई जाती है, तो मु$य िनयंक )ारा िनयम0 के अधीन मा<यता दान कर दी जाएगी; या

(ख)य+द कोई आवेदक उपयु; त नह_ पाया जाता है तो मु$य िनयंक )ारा कारण0 को िविनUद R ट करते Bए आवेदन को अवीकार कर +दया जाएगा।
(v) ारंभ म उप-खंड (iv) के अधीन जारी मा< यता एक वष क! अविध के िलए िविधमा< य रहेगी । तAपmात् काय िनRपादन Oरपोट के आधार पर और दो वष क! अविध के िलए मा< यता क! िविधमा< यता का नवीकरण +कया जा सकता है। (vi) मु$य िनयंक ऑपरेटर को जारी क! गई मा< यता को ितसंnत या िनलंिबत कर सकते है य+द ऑपरेटर इस अनुसूची म यथा व^ण त दाियAव0 को पूण नह_ करता। (vii) मु$य िनयंक )ारा ऑपरेटर को सुने जाने का एक अवसर देने के पmात् मा<यता ितसंnत क! जा सकती है– (क) य+द उनके पास यह मानने का पया 5 कारण है +क ऑपरेटर, )ारा मा<यता प म उि]लिखत +कसी शत का उ]लंघन +कया गया है या उनके )ारा इन िनयम0 के योजन या आशय के असंगत कोई काय +कया गया है; या (ख) उन कारण0 के िलए जो लेखबp +कए जाएँ”। 11.
उ; त िनयम0 के, अनुसूची 4 के  थान पर, िन? निलिखत अनुसूची रखी जाएगी, अथा त्:- “अनुसूची 4 अनुसूची 4 अनुसूची 4 अनुसूची 4 [िनयम 2( िनयम 2( िनयम 2( िनयम 2(vक) क) क) क), 21 (15) और 29 21 (15) और 29 21 (15) और 29 21 (15) और 29 देख देख देख देख] एलएनजी एलएनजी एलएनजी एलएनजी भ डारण भ डारण भ डारण भ डारण, , , , संभलाई संभलाई संभलाई संभलाई (है ड है ड है ड है ड#लंग #लंग #लंग #लंग), प'रवहन प'रवहन प'रवहन प'रवहन, चालन

र 29 देख देख देख देख] एलएनजी एलएनजी एलएनजी एलएनजी भ डारण भ डारण भ डारण भ डारण, , , , संभलाई संभलाई संभलाई संभलाई (है ड है ड है ड है ड#लंग #लंग #लंग #लंग), प'रवहन प'रवहन प'रवहन प'रवहन, चालन

चालन

चालन

चालन, रखरखाव रखरखाव रखरखाव रखरखाव और िवतरण और िवतरण और िवतरण और िवतरण ये उपबंध िनrिलिखत को लागू ह0गे – (क) अनुमो+दत दाबपा संिहता के अनुसार िन^म त दोहरी वॉल वाले ाशीतनी िनवा त रोधी (Zायोजेिनक वै;यूम इनसूलेटेड) पा0 के उपयोग )ारा िडज़ाइन, संिवरचन (फैिsकेशन) और अिधYापन और एलएनजी भJडारण सुिवधा\ को शु करने क! अपे7ा\ म और सुरि7त वाRपीकरण, अंतरण और संभलाई क! अपे7ा\ म।

¹Hkkx IIµ[k.M 3(i)º 5 (ख) सुरि7त पOरवहन और संभलाई के िलए दोहरी वॉल वाले ाशीतनी िनवा त रोधी पा0 म सड़क )ारा एलएनजी के पOरवहन क! अपे7ा\ म। (ग) चालन, रखरखाव और िश7ण म। (घ) एलसीएनजी टेशन या ऑटो एलएनजी िवतरण: पर< तु यह +क मु$य िनयंक, असाधारण पOरिथितय0 अधीन, और लेखबp कारण0 के िलए, इस अनुसूची क! आवH यकता\ का अिधA यजन कर सकते ह3।

ख ड ख ड ख ड ख ड 1 भ डारण भ डारण भ डारण भ डारण अिध+ापन और संभलाई अिध+ापन और संभलाई अिध+ापन और संभलाई अिध+ापन और संभलाई (है ड है ड है ड है ड#लंग #लंग #लंग #लंग) क. . . . – अिध+ापन अिध+ापन अिध+ापन अिध+ापन िडजाइन िडजाइन िडजाइन िडजाइन (1) (क) एलएनजी Zायोजेिनक दाबपा भJडारण अिधYापन के िलए पा और िनकटतम भवन या िनकटवतt स?पिE क! सीमा के बीच <यूनतम सुर7ा दूरी इस अनुसूची क! साOरणी (1) म िनUद V दूOरय0 के अनुसार होगी। A येक ऐसे एलएनजी अिधYापन0 क! अिधकतम कुल 7मता 1060 घन मीटर से अिधक नह_ होनी चािहए। (ख) गैरदबाव एलएनजी भJडारण सं थापन0 के िलए एनएफपीए 59क म िविनUद V, समय समय पर यथा संशोिधत <यूनतम सुर7ा दूरी का पालन +कया जाना चािहए। 2.

पन0 क! अिधकतम कुल 7मता 1060 घन मीटर से अिधक नह_ होनी चािहए। (ख) गैरदबाव एलएनजी भJडारण सं थापन0 के िलए एनएफपीए 59क म िविनUद V, समय समय पर यथा संशोिधत <यूनतम सुर7ा दूरी का पालन +कया जाना चािहए। 2. एलएनजी अिधYापन इस तरह से अिभकि]पत +कया जाना चािहए +क ढांचागत या +ZयाAमक समuता म +कसी कार के नुकसान के िबना, िनrिलिखत को सह सके -

(क) वायुबल के सीधे भाव को;

(ख) भूकंपीय भाव के कारण Bए लदाई को;

(ग) छलकने के कारण Bए 7रणकारी (इरोिसव) +Zया; (घ) तापमान, तापीय झुकाव और एलएनजी से थानीय स?पक या अचानक +कसी अ<य Aयािशत िगरावट का भाव। 3. अिववेक! (इ?पाउ< डमे< ट) णाली क! ढांचागत अिभक]पना (िडजाइन) और िनमा ण इस कार होना चािहए +क िनrिलिखत के पOरणामवप अिववेक! (इ?पाउ< डमे< ट) क! िवvसनीयता और ढांचागत समuता के हािन को रोक सके–

क) ए?पwडेड (असावधानी) एलएनजी के पूण =वथैितक हेड से लादा गया भार;

ख) अंतः7ेिपत सामuी से Bई हाइxोडायनािमक +Zया। 4. इ?पाउ< डमे< ट या डाइक 7े अिभकि]पत होने चािहए ता+क पानी एकित न होकर सभी पानी बह जाए। अिववेक! (इ?पाउ< डमे< ट) 7े0 म एकित पानी को हटाने के िलए xेनेज प?प0 और पाइyपंzस का उपबंध हो। जहाँ विनयंित xेनेज प?प का उपयोग +कया जा रहा है उनम कट-ऑफ िडवाइस का उपबंध +कया जाना चािहए ता+क एलएनजी तापमान के सम7 आने पर उनका चालन ब<द हो जाए। 5.
कंेसर, सीएनजी कासके{स, ओडोराइजर, आ+द इ?पाउy<डंग पOरसर के भीतर िथत नह_ +कए जाए। 6.
पOरवेशी वािRप और दूर त> त वािRप सुिवधा, इ?पाउy<डंग 7े के भीतर िथत हो सकते ह3। 7.

चालन ब<द हो जाए। 5.
कंेसर, सीएनजी कासके{स, ओडोराइजर, आ+द इ?पाउy<डंग पOरसर के भीतर िथत नह_ +कए जाए। 6.
पOरवेशी वािRप और दूर त> त वािRप सुिवधा, इ?पाउy<डंग 7े के भीतर िथत हो सकते ह3। 7. एलएनजी भJडारण पा के इ?पाउy<डंग णाली क! िनrिलिखत आयतनी =व 7मता होनी चािहए – (क) +कसी एक पा म यु/ अिववेक! (इ?पाउ< डमे< ट) के िलए पा क! अिधकतम =व धाOरता;
(ख) एक से अिधक पा क! सेवा म सबसे बड़े पा के अिधकतम =व 7मता का शत ितशत।
8. इ?पाउ< डमे< ट वाल क! ऊँचाई इतनी होनी चािहए +क एलएनजी छलकने पर उससे बाहर न जाए। डाइक वॉल के िलए डाइक के < यूनतम  तर से 0.6 मीटर से 1.0 मीटर क! ऊँचाई अनुशंिसत क! जाती है। पा क! न_व क! ऊंचाई

6
[PART II—SEC. 3(i)]

कम से कम 0.4 मीटर होगी या इस तरह से अिभकि]पत होनी चािहए ता+क काब न टील सामuी का, िगरे Bए एलएनजी के संपक से बचाया जा सके। 9. एलएनजी इ?पाउy<डंग 7े के अ<दर कोई अ<य वलनशील =व या भJडारण पा िथत नह_ होगा। 10. बB पा0 म लगे पृथक वा].स तक पBँचने के िलए 0.9 मीटर का पV खुला 7े होना चािहए। एलएनजी ट3क पाइyपंग का पृथक वा]व, बाहरी पा के िजतना स?भव हो, नजदीक होना चािहए। 11 डाइक के भीतर थािपत एलएनजी पा शीतल बो;स पाइप लाइन और पाइप का सहारा और Zायोजेिनक उपकरण0 को इस कार िडजाइन और िनमा ण करना चािहए +क इन संरचना और उपकरण0 को जमीन क! नमी से जमी िहम और ठंड से नुकसान न हो।
12 राि के दौरान एलएनजी थाना<तOरत करने क! सुिवधा के थान0 पर समुिचत वालासह काश क! iवथा करनी चािहए। 13 िव ुतीय समूहीकरण और अनुबंधन उपल2 ध +कया जाना चािहए। 14 लेआउट, हर समय उपभो/ा\ और आपू^त यान0 का अबािधत आवागमन सुिनिmत करेगा। 15 वेश,  थान और फुटपाथ क! iवथा ऐसी क! जानी चािहए ता+क टकराव के जोिखम को कम +कया जाए। 16

नुबंधन उपल2 ध +कया जाना चािहए। 14 लेआउट, हर समय उपभो/ा\ और आपू^त यान0 का अबािधत आवागमन सुिनिmत करेगा। 15 वेश,  थान और फुटपाथ क! iवथा ऐसी क! जानी चािहए ता+क टकराव के जोिखम को कम +कया जाए। 16 चालन का^म क0 को िबZ! क7 और िवतरण 7े दोन0 से ही सुिवधा\ का अबािधत समu अवलोकन हो सक। 17 अिभिहत ट3कर के उतराई का अवथान ऐसा होना चािहए +क यह अ<य यातायात को बाधा न पBंचाए और साथ ही ट3कर क! बाहर जाने क! िथित ऐसी हो +क आपात िथित म पOरसर से आसानी से बाहर आ सक । 18 वाहन0 के आवागमन म दुघ टना\ के ित कमजोर उपकरण0 क! र7ा के िलए ट; कर/ भाव अवरोध थािपत +कए जाएंगे। 19 ऐसा भंडारण 7े िजसम पंप और संबंिधत पाइyपंग शािमल है, को पOरसर के अ< य िहस0 से पृथक कर देना चािहए और ऐसे  थान पर िथत होना चािहए +क वह  टेशन के भीतर के 7े म जनता के आवागमन के 7े से दूर हो और साथ ही यान0 के पOरसर म वेश करने और बाहर जाने के राते से भी दूर हो।

सारणी सारणी सारणी सारणी - 1 बाड़े बाड़े बाड़े बाड़े क दीवार क दीवार क दीवार क दीवार और और और और साम/ी साम/ी साम/ी साम/ी सेसेसेसे दूरी दूरी दूरी दूरी

Z. सं. पा क! जल 7मता (मी3) संपिE लाइन0 से बाड़े या पा जल िनकासी iवथा के +कनारे से <यूनतम दूरी भंडारण पा0 के बीच <यूनतम दूरी 1.
3.8 से अनिधक 3 मी 0.5 मी

  1. 3.8 से अिधक }कंतु 7.6 से अनिधक 5.0 मी 1.0 मी
  2. 7.6 से अिधक }कंतु 56.8 से अनिधक 8.0 मी 1.5 मी
  3. 56.8 से अिधक }कंतु 114.0 से अनिधक 15.0 मी
    1.5 मी
  4. 114.0 से अिधक }कंतु 265.0 से अनिधक
    25.0 मी
    आस~ पा0 के iास के योग का ¼ (कम से कम 1.5 मी)
  5. 265.0 से अिधक }कंतु 379 से अनिधक
    पा iास (<यूनतम 30.0 मीटर)

अनिधक 15.0 मी
1.5 मी
5. 114.0 से अिधक }कंतु 265.0 से अनिधक
25.0 मी
आस~ पा0 के iास के योग का ¼ (कम से कम 1.5 मी)
6. 265.0 से अिधक }कंतु 379 से अनिधक
पा iास (<यूनतम 30.0 मीटर)

¹Hkkx IIµ[k.M 3(i)º 7

सारणी सारणी सारणी सारणी -2 पा0 और डाइक पा0 और डाइक पा0 और डाइक पा0 और डाइक वाल वाल वाल वाल के बीच क  यू के बीच क  यू के बीच क  यू के बीच क  यूनतम दूरी नतम दूरी नतम दूरी नतम दूरी

Z. सं. पा क! जल 7मता (मी3) डाइक वाल के अंदनी +कनारे और भंडारण पा के बाहरी शेल या डी/ 2 जो भी अिधक है 1 3.8 से अनिधक 0.5 मी

2 3.8 से अिधक }कंतु 7.6 से अनिधक 1.0 मी

3 7.6 से अिधक }कंतु 56.8 से अनिधक 1.5 मी 4 56.8 से अिधक }कंतु 114.0 से अनिधक 1.5 मी
5 114.0 से अिधक }कंतु 265.0 से अनिधक

आस~ पा0 के iास के योग का ¼ (कम से कम 1.5 मी)
6 265.0 से अिधक }कंतु 379 से अनिधक

सारणी सारणी सारणी सारणी -3 डाइक वाल के डाइक वाल के डाइक वाल के डाइक वाल के बाहर और डाइक वाल के बाहरी छोर के बीच 7 था बाहर और डाइक वाल के बाहरी छोर के बीच 7 था बाहर और डाइक वाल के बाहरी छोर के बीच 7 था बाहर और डाइक वाल के बाहरी छोर के बीच 7 थािपत उपकरण:/ मद: के िपत उपकरण:/ मद: के िपत उपकरण:/ मद: के िपत उपकरण:/ मद: के बीच क बीच क बीच क बीच क यूनतम दूरी यूनतम दूरी यूनतम दूरी यूनतम दूरी .सं. .सं. .सं. .सं. उप7 क उप7 क उप7 क उप7 कर/ / / / आइटम आइटम आइटम आइटम डाइक डाइक डाइक डाइक वाल वाल वाल वाल (बाहरी <कनारा) (बाहरी <कनारा) (बाहरी <कनारा) (बाहरी <कनारा) 1. सीमा संपिE / बाड़ा (फyसंग) इस अनुसूची क! सारणी (1) के अनुसार
2.

/ / / / आइटम आइटम आइटम आइटम डाइक डाइक डाइक डाइक वाल वाल वाल वाल (बाहरी <कनारा) (बाहरी <कनारा) (बाहरी <कनारा) (बाहरी <कनारा) 1. सीमा संपिE / बाड़ा (फyसंग) इस अनुसूची क! सारणी (1) के अनुसार
2. Xक उतराई चबूतरे का म य
< यूनतम 4.0 मी (सटी सीमा/ संपिE से भी 9 मी) सटी सीमा से +फल पॉPट )ारा 9.0 मीटर क! दूरी रखी जाएगी। 3. ाथिमकता पैनल डाइक क! दीवार से बाहर 4. सीएनजी कासकेड (एलसीएनजी टेशन के िलए) गैस िसलडर िनयम, 2016 क! सारणी 1 क के अनुसार डाइक के +कनारे से सुर7ा दूरी। काकेड क! ऊंचाई तक कंZ!ट वाल उपल2 ध कराकर एलएनजी सुिवधा से काकेड पृथक +कया जाएगा। 5. िनमा ण के साइट पर / िनयंण क7 / िबZ! काया लय
इस अनुसूची क! सारणी 1 के अनुसार सुर7ा दूरी से बाहर
6. एलएनजी और सीएनजी िडपसर (य+द एलसीएनजी टेशन)
< यूनतम 6.0 मी (हाड ट3ड के म य से भी < यूनतम 6.0 मीटर) 7. िडपसर )ीप के बीच क! दूरी
< यूनतम 6.0 मी

8
[PART II—SEC. 3(i)]

ख.

एलएनजी

एलएनजी एलएनजी एलएनजी भ डारण भ डारण भ डारण भ डारण पा0 पा0 पा0 पा0- साधारण साधारण साधारण साधारण अिभक=पना अिभक=पना अिभक=पना अिभक=पना (िडजाइन िडजाइन िडजाइन िडजाइन) ) ) ) अपेाएं अपेाएं अपेाएं अपेाएं:- (क) बुिनयादः बुिनयादः बुिनयादः बुिनयादः (1) एलएनजी पा0 क! न_व एक अ^ह त इंिजिनयर के )ारा अिभक]पना (िडजाइन) करनी चािहए और िनमा ण मा<यता ा5 इंिजिनयरी णाली के अनुसार करना चािहए। न_व के िनमा ण और अिभक]पना (िडजाइन) से पहले अ<त भूिम क! जांच एक योzय मृदा इंजीिनयर के )ारा करानी चािहए ता+क उ/ भूिम क!  XेOटuाफ! और भौितक गुण0 को gात +कया जा सके। (2) एलएनजी पा के काठी और पाय के अिभक]पना (िडजाइन) करते समय िनमा णभार हवा\ का भार और तापीय भार को भी शािमल करना चािहए।

रा करानी चािहए ता+क उ/ भूिम क!  XेOटuाफ! और भौितक गुण0 को gात +कया जा सके। (2) एलएनजी पा के काठी और पाय के अिभक]पना (िडजाइन) करते समय िनमा णभार हवा\ का भार और तापीय भार को भी शािमल करना चािहए।
(3) न_व और समथ क! अिl रोधी 7मता कम से कम दो घंटे क! दज क! हो।
(4) बाढ़ संभािवत 7े0 म  थािपत एलएनजी पा को बाढ़ क! दशा म एलएनजी Oरहाई से रोकने के िलए सुरि7त अथवा पा के तैरने से रोकने के िलए इ<तजाम होने चािहए। (ख)

पा0 पा0 पा0 पा0 अिभक=पना अिभक=पना अिभक=पना अिभक=पना (िडजाइन िडजाइन िडजाइन िडजाइन): (1) एलएनजी भJडारण के िलए वांिछत पा आ<तOरक और बा„ के बीच क! पाइप लाइन सिहत एएसएमई बॉइलर एJ ड ेशर वेसल कोड से;शन VIII डीवीजन 1/इएन 13458/ एएसएमई:बी.31.3 के अनुप बना होना चािहए। +Zया पाइप लाइन अथवा समतु] य कोड मु$य िनयंक )ारा वीक़ृत होना चािहए। (2) ऑटो एलएनजी भंडारण पा का िडजाइन दाब 20.0 +कलोuाम/सेमी2 से अिधक नह_ होगा।
(3) आ<तOरक पा को आ<तOरक दाब और =व मद के सबसे महAवपूण संयोजन के िलये अिभकि]पत (िडजाइन) करना चािहए। अ<त:पा के सहायक िनकाय को पोतभार, भूक?प संबंधी भार और सं+Zयाभार के िलए िडजाइन करना चािहए।
(4) बाहरी पा को आ<तOरक दाब िनकालने हेतु अनुतोष या अ<य युि/ के साथ लगाना चािहए और उसका िवसज न 7ेफल आ<तOरक पा क! जलधाOरता का कम से कम 0.34 वग मीमी/ लीटर होना चािहए पर<तु यह 2000 वग सेमी से अिधक न हो और इसक! दबाव से[टंग 25 पीएसआई से अिधक न हो। (5) बाहरी पा को इसके अिभक]पना (िडजाइन) तापमान से कम तापमान पर जाने से रोकने के िलए तापीय बाधा लगानी चािहए। (6) एलएनजी पा के वे सभी भाग जो एलएनजी के स?पक म आये और वे सभी सामuी जो ठंडी एलएनजी वाRप या एलएनजी के स?पक म आये को (-)1620 सेि]सयस तक सहन करने के साथ-साथ भौितक और रासायिनक

बाधा लगानी चािहए। (6) एलएनजी पा के वे सभी भाग जो एलएनजी के स?पक म आये और वे सभी सामuी जो ठंडी एलएनजी वाRप या एलएनजी के स?पक म आये को (-)1620 सेि]सयस तक सहन करने के साथ-साथ भौितक और रासायिनक †ृिR ट से एलएनजी के साथ संयो य हो। (7) एलएनजी पा क! सभी पाइप लाइन पा के आ<तOरक मय का खाली थान और बाहरी पा के बाहर पहले पOरधीय जोड़ जहां बाहरी पाइप लाइन के साथ संयु; त +कया जाता है को एएसएमई बाइलर और ेसर वेसल कोड से;शन VIII या एएसएमई-बी 31.3 के अनुप या समतु]य होना चािहए। (8) एलएनजी पा को िशखर और तली दोन0 जगह से भरने के िलये अिभक]पना (िडजाइन) करना चािहए जब तक +क तर िव<यास को रोकने के अ<य सकाराAमक साधन न हो।
(9) एलएनजी पा के बाहरी सतह का कोई भी भाग जो अचानक ‡ले<ज, वा]व, आ+द से Bए Oरसाव के कारण अचानक िन? न ताप के संपक म आता है, को ऐसे तापमान के िलए आशियत या संपक म आने से होने वाले वाले भाव से संरि7त +कया जाएगा।
(10) एलएनजी पा क! सहायक णाली को अिभक]पना (िडजाइन) करते समय भूक?प संबंधी भार को भी यान रखना चािहए। ग.

<फटम@सः <फटम@सः <फटम@सः <फटम@सः (1) Aयेक एलएनजी दोहरी िभिE पा पर कम से कम 2 सुर7ा राहत वा]व जो एकल आधार पर आवHयक सुर7ा राहत पूरी कर सके, क! 7मता का लगाना होगा और जो सबसे बड़ी एकल संभा. यता या अ< य उिचत

टम@सः <फटम@सः <फटम@सः (1) Aयेक एलएनजी दोहरी िभिE पा पर कम से कम 2 सुर7ा राहत वा]व जो एकल आधार पर आवHयक सुर7ा राहत पूरी कर सके, क! 7मता का लगाना होगा और जो सबसे बड़ी एकल संभा. यता या अ< य उिचत

¹Hkkx IIµ[k.M 3(i)º 9 संभा. यता के संयोजन के िलए िनिmत वाह 7मता हेतु बनाया जाएगा और िजसम, पOरचालन क! ख़राबी, वाRप िवथापन और ‡लैश वाRपीकरण से उAप~ िथितया शािमल ह0गी। (2) अनुतोष उपकरण सीधे वायुमJडल म वट करेगा । एलएनजी पा पर लगाया Bआ Aयेक सुर7ा राहत वा]व को मर??त या अ<य योजन के िलये हाथ के )ारा पूरा खुलने और बंद होने वाले वा]व या ‡लो डाइवट र वॉ] व के मा यम से, पा से पृथ;कृत +कया जाएगा। (3) सुर7ा राहत वा]व को इस कार अिभि]पत(िडजाइन) और थािपत +कया जायेगा +क अंत म इसम कोई पानी या अ<य अवांछनीय पदाथ एकित न हो पाये। (4) <यूनतम दाब राहत 7मता +क uा/घंटा म स?पूण ट3क क! 24 घंट0 क! 7मता के 3 ितशत से कम न हो। (5) एलएनजी पा से जुड़े सभी =वीय लाइन सुर7ा राहत वा]व और यंीय संयोजन के अलावा, को वत: फेल सेफ और उAपाद Oरटशन वा]व से उपकOरत +कया जायेगा। (6) ऑटोमैOटक शटऑफ वा]व को िनrिलिखत कारक0 के घOटत होने पर िन? निलिखत शत‰ पर ब<द होने के िलए अिभि]पत +कया जायेगा-
(i) अिl का पता लगाने के िलए;
(ii) पा से एलएनजी का अिनयंित बहाव;
(iii) थानीय और दूरथ मानवीय सं+Zयाएं। (7) ऐसे  वचिलत शटऑफ वा]व िजनको आपातकाल म ब<द होने म अAयिधक समय लगाता हो, जैसे +क 200 िम.मी.

का पता लगाने के िलए;
(ii) पा से एलएनजी का अिनयंित बहाव;
(iii) थानीय और दूरथ मानवीय सं+Zयाएं। (7) ऐसे  वचिलत शटऑफ वा]व िजनको आपातकाल म ब<द होने म अAयिधक समय लगाता हो, जैसे +क 200 िम.मी. से बड़े आकार को वायवीय (< यूमैOटकली) चािलत बनाया जायेगा और मानवीय सं+Zया का भी उपब<ध होगा। (8) समत एलएनजी पा पर ऐसी युि/ होगी जो पा को Šव से पूरा भरने से रोकेगी या राहत वा]व के अ<दर के िहसे को Šव सतह म डूबने से समत पOरिथितय0 जब+क वेसल का दबाव सेट दबाव के समान हो, रोकेगी। (9) Aयेक एलएनजी पा पर एक वत< उ‹ च तर अलाम का ावधान +कया जाएगा जो +क =व सतह मापन युि/य0 का िहसा होगा, य िप उŒ =व सतह कट ऑफ युि/ को अलाम के िलए एक िवक]प के प म नह_ माना जाएगा। (10) Aयेक एलएनजी पा को कम से कम एक =व सतह मापन युि/ से सुसित +कया जायेगा। युि/ को इस कार अिभकि]पत (िडजाइन) और थािपत +कया जायेगा +क इसे मु$य पा को िबना सं+Zया +कये बदला जा सकेगा। उतराई/ लदान और अंतरण के दौरान पOरचालन क^म य0 को उसका तर और दाब +दखाई देगा। (11) Aयेक एलएनजी पा एक उŒ =व सतह कट ऑफ युि/ से सुसित होगा। (12) Aयेक एलएनजी पा के अिधकतम तरल तर के ऊपर एक yबंदु पर दाबमापी के साथ सुसित +कया जाएगा। (13) भJडारण और वाRपीकरण सुिवधा\ के िलए यंीकरण (इ<Žमेटशन) इस कार िडजाइन करना चािहए +क िव ुत अनापू^त या वायु अनापू^त के समय णली एक फेलसेफ दशा म चली जाये और तब तक उसी िथित म रहे जब तक +क चालक पुन: उिचत कार वाई ना कर ल या णाली को पुन: स+Zय या सुरि7त न कर द। घ.

इन करना चािहए +क िव ुत अनापू^त या वायु अनापू^त के समय णली एक फेलसेफ दशा म चली जाये और तब तक उसी िथित म रहे जब तक +क चालक पुन: उिचत कार वाई ना कर ल या णाली को पुन: स+Zय या सुरि7त न कर द। घ.

   उप7 क

उप7 क उप7 क उप7 कर: र: र: र:

(1) एलएनजी ोत म काय रत प?प और कंेसर को ेशर Oरिलyवंब युि/ सिहत होना चािहए ता+क अिधकतम सुरि7त काय कारी दाब को +फ yलंग और उसके आगे पाइप लाइन एवं उप कर0 म सीिमत रखा जा सक । (2) Aयेक प?प पर उपयु/ िनकास, राहत वा]व या दोन0 लगाने चािहये ता+क अिधकतम स?भािवत शीतलन दर क! दशा म प?प केyसंग अित दबाव म न आए। (3) Aयेक वािRप के ऊपर थािपत हर वािRप का िनव हन वा]व और पाइyपंग के घटक0 और आऊटलेट वा]व/  पेक sेक ‡लज, एलएनजी तापमान पर ऑपरेशन के िलए अिभकि]पत (िडजाइन) +कए जाएंगे।

10
[PART II—SEC. 3(i)]

(4) वािRप म एलएनजी के Oरसाव को रोकने के िलए िनिRZय, मैिनफो] डेड वािRप को अलग-थलग करने के िलए दो इनलेट वा]व का ावधान +कया जाएगा। य+द वाRपीकरण का इनलेट पाइप आकार 50 िम.मी.

PART II—SEC. 3(i)]

(4) वािRप म एलएनजी के Oरसाव को रोकने के िलए िनिRZय, मैिनफो] डेड वािRप को अलग-थलग करने के िलए दो इनलेट वा]व का ावधान +कया जाएगा। य+द वाRपीकरण का इनलेट पाइप आकार 50 िम.मी. iास से यादा है तो उसके इनलेट भाग म उपिथत दोन0 वा]व0 के बीच एकित एलएनजी को सुOर7त थान पर िनकालने के िलये उपबंध होना चािहये। (5) (i) पOरवेशी वायु वािRप को ही पOरसर म लगाना चािहये। (ii) जहां तापीय वाRपीकारक तापीय ोत से 15 मी या उससे अिधक दूरी पर है वहां Oरमोट शट ऑफ युि/ वाRपीकारक से <यूनतम 15 मी होनी चािहए। (iii) जहां तापीय वाRपीकारक तापीय ोत से 15 मी से कम दूरी पर िथत है इसक! एलएनजी Šव पाइप लाइन म आटोमेOटक शटऑफ वा]व वाRपीकारक से 3 मी क! दूरी पर लगा होना चािहये और जो िनrकारक0 के घOटत होने पर ब<द होगाः

(1) लाइन म दबाव ास (अितOर; त वाह)। (2) इस योजन हेतु अिभकि]पत +कए गए उपकरण )ारा पOरसीिमत 7े म आग का पता लगाने के िलए।

(3) वािRप के बाद वाह क! ओर तापमान कम होने पर।

(4) मैनुअल ई एस डी ि’व
(iv) (क) कोई भी पOरवेशी अथवा त> त वािRप जो एलएनजी पा के 15 मीटर के अंदर थािपत हो, को एलएनजी =िवत लाईन म आटोमेOटक शट आफ वा]व होना चािहए।

(ख) आटोमेOटक शट आफ वा]व iापक अथवा त5 वािRप से कम से कम
3 मीटर पर होना चािहए और िनrिलिखत +कसी भी िथित म बंद होना चािहए, अथा त्ः

    (1) लाइन म दबाव ास (अितOर; त वाह)। 

(2) वािRप के आसपास दशा ए गये असामा<य तापमान (अfXu)।
(3) वािRप के बाद वाह क! ओर तापमान कम होने पर। (4) आपातकालीन (इमरजसी) शटडाउन िसटम (इएसडी) क! स+Zयता (ग) य+द कोई इस सुिवधा म सहभागी है तो उपरो;

(3) वािRप के बाद वाह क! ओर तापमान कम होने पर। (4) आपातकालीन (इमरजसी) शटडाउन िसटम (इएसडी) क! स+Zयता (ग) य+द कोई इस सुिवधा म सहभागी है तो उपरो; त पैरा (क) म िनUद R ट आवH यकता\ के अितOर; त शट आफ वा]व का मेनुअल आपरेशन वािRप से कम से कम 15 मीटर के yबंदु से होना चािहए।
(v) उपरो/ शत‰, दाब िनमा ण करने वाले कॉयल या एलएनजी - से- सीएनजी (एलसीएनजी) णाली के अलावा अ<य योजन0 के िलए, एलएनजी वािRप0 के िलए लागू ह0गी। (6) वािRप0 (वेपोराइजरो) क! बीच क! दूरी कम से कम 1 मीटर रखी जानी चािहए। (7) एएसएमई बायलर और दाब पा संिहता, से;शन 8, भाग -1 क! अपे7ा\ के या मु$य िनयंक )ारा वीकाय अ< य समक7 संिहता के अनुप वािRप0 को अिभि]पत (िडजाइन), संिवरिचत और िनरीि7त +कया जाएगा। (8) एलएनजी वािRप0 के िनमा ण क! सामuी बाहरी ए]यूमीिनयम पंख के साथ ऑ टेिनOटक टेनलेस टील पाइyपंग क! होगी। (9) मैिनफो] ड वेपोराइजर0 को दोन0 ओर वेिशका और िनग म 2लॉक वा].स तथा A येक वािRप के िलए उपल2 ध +कए जाने चािहए। (10) कोई भी पOरवेशी वािRप जो+क एलएनजी के पा से 15 मीटर क! दूरी के अंदर थािपत हो, उसके =व लाईन म आटोमेOटक शट आफ वा]व लगा होना चािहए। इस वा]व को वािRप से कम से कम 3 मीटर पर होना चािहए तथा जब लाईन दाब क! हािन हो या वािRप के आसपास असामा<य तापमान महसूस +कया जाता है या दाब कम हो अथवा वािRप िनग म लाईन म िन? न तापमान हो जाए, तो वॉ] व बंद हो जाए। (11) वािRप के Aयेक आकृित (सेट) के िलए एक सुर7ा Oरलीफ वा]व उपल2 ध +कया जाना चािहए िजसके पOरमाप िनrिलिखत अपे7ा\ के अनुसार होने चािहएः

(क) पOरवेशी वािRप– Oरलीफ वा]व दाब को वािRप के अिधकतम वीकाय दाब म 10% बढ़ोEरी

(सेट) के िलए एक सुर7ा Oरलीफ वा]व उपल2 ध +कया जाना चािहए िजसके पOरमाप िनrिलिखत अपे7ा\ के अनुसार होने चािहएः

(क) पOरवेशी वािRप– Oरलीफ वा]व दाब को वािRप के अिधकतम वीकाय दाब म 10% बढ़ोEरी +कए िबना, वािRप के ाकृितक गैस बहाव 7मता के 150% से यादा या बराबर Oरलीफ वा]व 7मता िनग म  वीकार करेगा,

¹Hkkx IIµ[k.M 3(i)º 11 (ख) त5 वेपोराइजरो हेतु Oरलीफ वा]वस – उपरो; तानुसार, य िप यह इस कार से थािपत होना चािहए +क सामा<य +Zया के दौरान तापमान 600 सेि]सयस से अिधक न हो।
(12) एलएनजी अथवा वािRप गैस के िवतरण णाली म िनग मन जब सेJड आउट णाली के तापमान िडजाईन तापमान के ऊपर या नीचे होने से बचाने के िलए  वचािलत यं का उपाबंध होना चािहए। (13) वािRप0 का ावधान िनग म तापमान मािनटस के साथ +कया जाना चािहए। ङ.
.
.
. पाईप पाईप पाईप पाईप णालीः

णालीः

णालीः

णालीः (1) सभी पाईप णाली और उपकरण0 को अिभक]पना (िडजाइन) +कया होना चािहएः

(क) थम ल साइy;लंग ;लांित के भाव को समायोिजत करना िजसके अधीन णाली होगी।

(ख) पाईप और पाईप जोड़0 पर तापमान के पOरवत न )ारा संकुचन तथा फैलाव का उपाबंध। (2) गाकेट और —ेड कंपाउं{स सिहत पाईप सामuी, संपूण तापमान क! सीमा िजसके वह अधीन होगा उसके दौरान संगत होना चािहए।
(3) सं थापन म लगाए गए वा]वस को ए;सटटेड बोनट कार का होने चािहए साथ म प3}कंग मुहरबंद इस िथित म हो िजससे ˜!yजंग )ारा Oरसाव और खराबी को रोका जा सके। (4) =व तर चेतावनी और 2लाइJड ‡ल ड अथवा >लzड संयोजन को छोड़कर सभी ट3क संयोजन0 को शट आफ वा]व का उपबंध होना चािहए। (5) सभी पाईyपंग से;शन के बीच ऐसे दो वा]वस जहां =व फंसाया जा सके, तापीय अनुतोष वा]व होना चािहए। (6) वािRप सेवा म उAपाद ितधारण वा]व के नीचे क! ओर ही केवल ए]यूिमिनयम का इतेमाल +कया जाएगा।

ए। (5) सभी पाईyपंग से;शन के बीच ऐसे दो वा]वस जहां =व फंसाया जा सके, तापीय अनुतोष वा]व होना चािहए। (6) वािRप सेवा म उAपाद ितधारण वा]व के नीचे क! ओर ही केवल ए]यूिमिनयम का इतेमाल +कया जाएगा।
च.
.
.
. एलएनजी एलएनजी एलएनजी एलएनजी का का का का अतरणः अतरणः अतरणः अतरणः (1) Aयेक थाना<तरण णाली को पृथक करने हेतु पृथक वा]व सं थािपत होना चािहए। जहां िव ुत संचािलत पृथक वा]व थािपत हो, वहां बंद होने के समय का िव™ेषण होना चािहए िजससे +क इतना हाइxोिलक शॉक पैदा न हो िजसके कारण लाईन अथवा उप कर खराब हो।
(2) पीछे के धारा वाह को रोकने हेतु पया 5 चेक वा]व होना चािहए और ऐसे नजदीक! जगह थािपत हो जो +कसी भी णाली के संयोजन yबंदु से iावहाOरक हो जहां पीछे का धारा वाह हो सकता हो। छ.
.
.
. पBप पBप पBप पBप और और और और संपीडन संपीडन संपीडन संपीडन िनयं0णः िनयं0णः िनयं0णः िनयं0णः प?प अथवा संपीडन xाईव को बंद करने हेतु थानीय लगी Bई युि; त के अलावा एक तAपर उपल2ध सुदूर थािपत युि; त को बंद करने वाले उप कर से कम से कम 7.5 मीटर क! दूरी पर थािपत होना चािहए िजससे प?प को +कसी आपातकालीन िथित म बंद +कया जा सके।
ज. . . . टCक टCक टCक टCक यान यान यान यान उतराई उतराई उतराई उतराई सुिवधाएः सुिवधाएः सुिवधाएः सुिवधाएः (1) ट3क यान उतराई 7े को पया 5 आकार का होना चािहए िजसम यान को यादा मोड़ना नह_ पड़े।
(2) अ<तरण पाईप, प?पस और संपीडको को iवधान )ारा इस तरह से थािपत अथवा सुरि7त करना चािहए िजससे यान संचालन क! 7ित से वह सुरि7त हो।
(3) पृथक वा]वस और 2लीड कने;शन को उतराई बB निलका पर दोन0 =व और वाR प लाइन के िलए सं थािपत होना चािहए िजससे होजेज और आम स को बंद कर +दया जाए। िनग िमत =व और िडसकने;शन से पहले दाब रिहत कर। 2ली{स अथवा वे<šस को सुरि7त 7े म िनग मन होना चािहए।

िलका पर दोन0 =व और वाR प लाइन के िलए सं थािपत होना चािहए िजससे होजेज और आम स को बंद कर +दया जाए। िनग िमत =व और िडसकने;शन से पहले दाब रिहत कर। 2ली{स अथवा वे<šस को सुरि7त 7े म िनग मन होना चािहए।

12
[PART II—SEC. 3(i)]

झ. . . . आपातकालीन आपातकालीन आपातकालीन आपातकालीन बंद बंद बंद बंद करने करने करने करने क क क क णाली

णाली

णाली

णाली (इ एस डी इ एस डी इ एस डी इ एस डी िस7 ट िस7 ट िस7 ट िस7 टम) (1) Aयेक एलएनजी सुिवधा म इएसडी णाली लगाई जाए िजसे ऑपरेट करने पर एलएनजी का  ोत पृथक या बंद हो जाए और उप कर0 को बंद कर द जो आपातकाल को जोड़ने अथवा बनाये रखते ह0, य+द वह चालू हालत म हो।
(2) इएसडी णाली फेलसेफ िडजाइन का हो और इस तरह सं थािपत, अविथत हो, जो आपातकाल म या सामा< य िनयंण णाली के असफल होने पर िनिRZय होने से संरि7त कर।
(3) ईएसडी णाली क! शुआत, पुितका वचािलत, या दोन0 पुितका और वचािलत हो। मैनुअल ए;चूएटस को ऐसी जगह पर थािपत +कया जाना चािहए जहां आपातकाल म सुगमता से पBंच सक और उपकरण से कम से कम 15 मीटर क! दूरी पर हो जहां के िलए लगे ह0 और स?बि<धत काय से िवशेषतया िचि<हत होने चािहए। ञ. . . .

;चूएटस को ऐसी जगह पर थािपत +कया जाना चािहए जहां आपातकाल म सुगमता से पBंच सक और उपकरण से कम से कम 15 मीटर क! दूरी पर हो जहां के िलए लगे ह0 और स?बि<धत काय से िवशेषतया िचि<हत होने चािहए। ञ. . . . अिD संरण सुिवधाएः अिD संरण सुिवधाएः अिD संरण सुिवधाएः अिD संरण सुिवधाएः (1) Aयेक एलएनजी भंडारण सुिवधा म वलनशील गैस संसूचक उपल2 ध +कए जाएंगे, ऐसे संयं थल िजससे उस जगह जहां लगातार कोई रहता हो, से +दखने और सुनाई देने वाले चेतावनी स+Zय होने चािहए। (2) मॉिनटर क! जाने वाली गैस के एलइएल के 25 ितशत से अनिधक  तर पर वलनशील गैस िडटे; टर णाली )ारा ›i और दृHय अलाम स+Zय +कया जाएगा। (3) अिl (फायर) िडटे;टर को संय 7े तथा लगातार उपिथित वाले थान पर एक चेतावनी स+Zय होना चािहए य+द संय 7े के साथ लगातार कोई नह_ है। य+द मू]यांकन )ारा यह िनधा Oरत हो +क यह आवHयक है तो फायर और गैस िडटे;टर को ई एस डी णाली को स+Zय करने +दया जाएगा। (4) अिl जल दाय और िवतरण णाली का जोिखम के आधार पर उपबंध होना चािहए। तथािप, Oरसाव या रंग िनकलने क! दशा म एल एन जी वािJ यत बादल0 को िछतरान के िलए पंyपंग सुिवधा के साथ एल एन जी भंडारण ट3क 7मता < यूनतम 10 ितशत तक का अिz नशमन जल भंडारण ट3क या 5000 लीटर जो भी अिधक हो उपनंय +कया जाएगा।
(5) पोटkिबल अथवा पिहये वाले अिlशामक को सामOरक थान0 पर उपल2 ध +कया जाने चािहए। कम से कम
10 +क.uा. 7मता वाले चार ऐसे अिlशामक क! . यव था क! जानी चािहए। (6) एलएनजी ितYान0 म उपल2 ध +कया गया अिlशामक हाय ए; सपा< शन फोम और सूखे रासायिनक पाउडर पर आधाOरत होगा। ट. . . .

ने चािहए। कम से कम
10 +क.uा. 7मता वाले चार ऐसे अिlशामक क! . यव था क! जानी चािहए। (6) एलएनजी ितYान0 म उपल2 ध +कया गया अिlशामक हाय ए; सपा< शन फोम और सूखे रासायिनक पाउडर पर आधाOरत होगा। ट. . . . EिFगत EिFगत EिFगत EिFगत सुराः सुराः सुराः सुराः एलएनजी अिधR ठापन0 म उपकरण चलाने वाले Aयेक iि/ को िनrिलिखत iि/गत सुर7ा उपकरण से सुसित होना चािहए- i) एलएनजी िछड़काव से आंख0 क! सुर7ा हेतु उपयु/ चHमा ii) िन? नतािपक! =व क! हथलाई के िलए उपयु; त दताने
iii) संर7ाA मक पOरधान
iv) सुर7ा जूते ख ड ख ड ख ड ख ड 2 सड़क सड़क सड़क सड़क प'रवहन प'रवहन प'रवहन प'रवहन क. अिभक=पना अिभक=पना अिभक=पना अिभक=पना (िडजाइन िडजाइन िडजाइन िडजाइन) ) ) ) – साधारण साधारण साधारण साधारण अपेाएँ अपेाएँ अपेाएँ अपेाएँ: एलएनजी पOरवहन ट3क के अंदनी पा म लगाए गए सुर7ा Oरलीफ वा].स इस आकार के होने चािहए +क िनवा त और बा„ अिl क! एक साथ होने वाली कमी जैसे सवा िधक कOठन िथित से िनपट सके और सुर7ा वा]व0 क! संयु/ 7मता इतनी होनी चािहए +क वह पा के दाब को जाँच दाब क! पया > त सीमा म बनाए रखे। (1) पOरवहन पा धारा-3 भाग-1 एएसएमई बॉइलर एJ ड ेशर वेसल कोड, ईएन 13530 या मु$य
िनयंक (मुिन) )ारा अनुमो+दत समतु]य कोड के अनुसार तथा आईएसओ 20421 क! अपे7ा\ के अनुप अिभकि]पत और िन^म त होना चािहए और पा, पाइyपंग और वा].स का अिभक]पना (िडजाइन)

ड ेशर वेसल कोड, ईएन 13530 या मु$य
िनयंक (मुिन) )ारा अनुमो+दत समतु]य कोड के अनुसार तथा आईएसओ 20421 क! अपे7ा\ के अनुप अिभकि]पत और िन^म त होना चािहए और पा, पाइyपंग और वा].स का अिभक]पना (िडजाइन)

¹Hkkx IIµ[k.M 3(i)º 13 तापमान ऐसा होना चािहए +क वह पा क! जाँच और चालू करने के दौरान उसम =िवत नाइXोजन भरे जाने के पOरणामवप उसम उAप~ होने वाले को]ड शॉक को बनाए रखने के िलए उपयु/ हो। (2) Aयेक पा म पया 5 रोधन होना चािहए, जो +क पा को िनr अिभक]पना (िडजाइन) दशा\ म एलएनजी से भरा जाए तो िविनUद V धारण समय म, पा को Oरलीफ वा]व के िनधा Oरत दाब को उEेिजत करने से रोकेगा – क) एलएनजी का िविनUद V तापमान और दाब। ख) पा का 40 िडuी सेि]सयस औसत पOरवेशी तापमान पर अिभदश न। (3) एलएनजी के पOरवहन के िलए Zायोजिनक पा के बाहरी पा / जैकेट इ पात के अितOर/ अ<य +कसी सामuी का नह_ बना होना चािहए। (4) एलएनजी पOरवहन पा पर नमीयु/ बाहरी पा के बाहर क! ओर कोई ऐलुिमिनयम वा]व या +फ[टंग ितR ठािपत नह_ क! जानी चािहए और Aयेक पOरवहन पा म उिचत कार से वेि]डत अंदनी पा जो +क बा„ शेल से िघरा Bआ हो और दोन0 के मय िनवा त रोधन हो, का उपबंध होना चािहए। (ख) संरचनाH म संरचनाH म संरचनाH म संरचनाH मक सम/ताः सम/ताः सम/ताः सम/ताः

(1) एलएनजी के पOरवहन के िलए Aयेक पा का थैितक अिभक]पना (िडजाइन) और िनमा ण एएसएमई बॉइलर एJ ड ेशर वेसल धारा VIII भाग 1, ईएन13530 या मु$य िनयंक )ारा अनुमो+दत कोई अ<य कोड के अनुसार +कया जाना चािहए। पा के अिभक] पना म अिभक] पना दाब के कारण होने वाले तनाव, लदान का भार, पा क! दीवाल )ारा सम^थ त ढांचे का भार और लदान तथा पOरवेशी तापमान पराकोOट के पOरणामपप तापमान ावJय का भाव आ+द शािमल होगा।
(2)

के अिभक] पना म अिभक] पना दाब के कारण होने वाले तनाव, लदान का भार, पा क! दीवाल )ारा सम^थ त ढांचे का भार और लदान तथा पOरवेशी तापमान पराकोOट के पOरणामपप तापमान ावJय का भाव आ+द शािमल होगा।
(2) +कसी दुघ टना म संघात के कारण तनावो का पता लगाने के िलए, पा कवच और हे{स के अिभक]पना (िडजाइन) संगणना म 2जी के ल?बवत् अवAवरण के पOरणामवप गAयाAमक दाब के साथ िडजाइन दाब के संयोजन के पOरणामवप उAप~ भार भी शािमल होगा। इस लदान दशा के िलए, उपयोग +कए जाने वाला तनाव मू]य, िनमा ण सामuी के उAप~ बल के 75 ितशत से अिधक नह_ होगा।
(3) पा पर लगाए गए +फ[टंग और सहायक सामuी इस कार संरि7त होने चािहए +क ओवरटŸन ग के कारण Bई 7ित, चालन समuता को 7ीण न कर सके। यह संर7ण पा के, सुदृढ़ छ] ल0, संर7ाAमक छतरी या अनुथ या ल?बवत् भाग के िसिलJxीकेल ोफाइल के प म इस तरह गढ़ा होना चािहए +क भावी प से संर7ा दान क! जा सके। (4) पा के दीवाल के उपलlक0 क! वेy] डंग माउy<टंग पैड के संयोजन0 का बना होना चािहए ता+क पा के लदाई अवधारण समuता पर उसका कोई ितकूल भाव न पड़े। (ग)

दाब

दाब दाब दाब 'रलीफ 'रलीफ 'रलीफ 'रलीफ युिI त युिI त युिI त युिI तयां यां यां यां, , , , पाइ#पंग पाइ#पंग पाइ#पंग पाइ#पंग, वा=Jस वा=Jस वा=Jस वा=Jस और और और और <फKटंग <फKटंग <फKटंग <फKटंग: (1) होज, सेवा\ के िलए उपयु;

लीफ 'रलीफ 'रलीफ 'रलीफ युिI त युिI त युिI त युिI तयां यां यां यां, , , , पाइ#पंग पाइ#पंग पाइ#पंग पाइ#पंग, वा=Jस वा=Jस वा=Jस वा=Jस और और और और <फKटंग <फKटंग <फKटंग <फKटंग: (1) होज, सेवा\ के िलए उपयु; त ह0गे और काय करण दाब के कम से कम पाँच (5) गुना फटाव दाब (बŸट ग ेशर) के िलए िडजाईन +कए जाने चािहए। (2) य+द पेचदार पाइप का उपयोग +कया जा रहा है, पाइप और +फ[टंग अनुसूची 80 रेटेड या उससे अिधक रे[टंग का होना चािहए। (3) Aयेक होज कपyलंग को होज िडजाइन दबाव के कम से कम 120 ितशत पर अिभकि]पत होना चािहए और जब उ<ह जोड़ा जाये तब Oरसाव नह_ होना चािहए। (4) तापीय िवतार और संकुचन, झंझनाने और कंपन से होने वाली 7ित से पाइप0 को संरि7त रखना चािहए । िलप जोड़0 को उपयोग नह_ करना चािहए।
(5) सभी वा]व, पा िडजाईन स^व स तापमान पर पा िडजाइन दबाव के िलए उपयु; त होने चािहए।
(6) Aयेक +फ[टंग, अिधकतम पादाब के अनुसार रेटेड होना चािहए और उस सबसे ठंडे तापमान के युि/यु; त होना चािहए जो वातिवक पOरथित म यु; त हो।
(7) जब भी पा के ऊपर दबाव बनाने वाली ¢ाइल का उपयोग हो, ¢ाइल से वा]व पर चेक वा]व से वाRप संयोजन िजतना पा खोल के समीप संभव हो ¢ाइल क! 7ित क! पOरथित म +दया जाना चािहए। ¢ाइल से वा]व के साथ =व संयोजन भी +दया जाना चािहए।

दबाव बनाने वाली ¢ाइल का उपयोग हो, ¢ाइल से वा]व पर चेक वा]व से वाRप संयोजन िजतना पा खोल के समीप संभव हो ¢ाइल क! 7ित क! पOरथित म +दया जाना चािहए। ¢ाइल से वा]व के साथ =व संयोजन भी +दया जाना चािहए।

14
[PART II—SEC. 3(i)]

(8) Aयेक पा को इसके होy]डंग समय के अनुसार िनधा Oरत +कया जाना चािहए, होy]डंग समय परी7ण )ारा िनधा Oरत वह समय है जो +क लदान से सामuी के सा?यवथा क! पOरिथित के दबाब से िनrतम दबाव के Oरिलफ वा]व . यव था तक पBंचने म लगता है।
(9) सभी Oरिलफ वा]व के िनव हन लाइन, वे<ट वा]व, 2लीड वा]व इAया+द वे<ट टैक से जुड़े होने चािहए जो +क एक सुरि7त ऊंचाई पर वे<ट होता हो।
(10) एलएनजी पOरवहन पा पर बŸट ग िडक का उपयोग नह_ होना चािहए। (11) Oरिलफ >लेट या >लग या बŸट ग िडक के योग )ारा ऐनुलर जगह म दबाब के आकिमक संचय से बाहरी खोल संरि7त होना चािहए। अनुतोष युि/ (से‡टी िडवाइस) को उस दबाब पर जो +क बाहरी ट3क के आ<तOरक िडजाइन दबाब से अिधक न हो, आ<तOरक ट3क के बाहरी िडजाइन दबाब या 25 पीएसआई, जो भी कम हो, पर काया Aमक होना चािहए।
(घ) ) ) ) दुघMटना दुघMटना दुघMटना दुघMटना नुकसानी नुकसानी नुकसानी नुकसानी संरणः संरणः संरणः संरणः (1) Aयेक वा]व,+फ[टंग, दबाव Oरिलफ युि/यां और पा के अ<य उपसाधन जो +क पा को ब<द दरिमयानी शट औफ वा]व या चेक वा]व से पृथक हो, मोटर यान ˜ेमवक या उपयु/ ट£र ितरोधी गाड के अ<दर या हाउyसंग म थािपत होना चािहए तथा उिचत वायु संचार भी होना चािहए। Aयेक दबाव Oरिलफ युि/ इस कार संरि7त होना चािहए ता+क यान के कठोर सतह पर पलटने पर, युि/ का िनकास अवp न हो व Oरसाव ितबंिधत न हो। —ेडेड एJड कने;शन से‡टी वा]व, टैनल इ पात संरचना म उपयोग होने चािहए।
(2) Aयेक र7ाAमक युि/ या हाउyसंग और यान X;चर के संलz नक जो इस कार अिभकि]पत होने चािहए +क

अवp न हो व Oरसाव ितबंिधत न हो। —ेडेड एJड कने;शन से‡टी वा]व, टैनल इ पात संरचना म उपयोग होने चािहए।
(2) Aयेक र7ाAमक युि/ या हाउyसंग और यान X;चर के संलz नक जो इस कार अिभकि]पत होने चािहए +क आगे,पीछे,बगल या बाजू से ट£र या यान के पलटने के कारण +कसी भी +दशा से लदान होने पर ये िथर लदान को झेल जाये। टैक के Aयेक वा]व, चालन ब;से (कैिबनेट) के पीछे से अ<दर क! ओर तथा उपयु/ आकार का होना चािहए और टैक iास से बाहर 7ेिपत नह_ होना चािहए। कैिबनेट क! मोटाई <यूनतम 3 िममी होगी।
(ङ) िपछले िपछले िपछले िपछले िह7से िह7से िह7से िह7से क क क क संरा संरा संरा संरा (1) पा के िपछले िहसे के संर7ण युि/ म, कम से कम एक िपछला ब?पर अिभकि]पत होगा जो िपछले भाग से ट£र क! िथित म पOरवहन पा और पाइyपंग को संरि7त रखेगा। पा के िपछले िहसे को संरि7त रखने के युि/ का िडजाइन, ट£र के बल को सीधे यान के चेिसस को संचाOरत करने वाला होना चािहए। पा के िपछले िहसे को संरि7त रखने के युि/ और इसके चेिसस के अनुलlक इस कार िडजाइन होने चािहए +क लदान के समय यु/ सामuी क! टसाईल  Xथ के 4 गुना सुर7ा गुणक का उपयोग करते Bए ये भरे Bए कागW पा और अनुलlक0 के भार का दुगना भार झेल जाये जब+क ये यान पा के मुख धुरी के समाना<तर और 7ैितज लगाया गया हो।
(2) लदे Bए पOरवहन पा और जुड़े Bए वा]व का Aयेक िहसा,पाइप,इ<;लोजर या संरि7त +फ[टंग या संरचना भू तल से कम से कम 35.5 सेमी ऊपर होनी चािहए। (च) िनवMहन िनवMहन िनवMहन िनवMहन िनयं0ण िनयं0ण िनयं0ण िनयं0ण युिFयाँ युिFयाँ युिFयाँ युिFयाँ: (1) Aयेक तरल भराव और तरल िनव हन लाइन म एक शट ऑफ वा]व पा के िजतना नजदीक स?भव को लगा होना चािहए। इस लाइन म मैनुअल शट औफ वा]व भी होना चािहए य+द वा]व हाथ से काम करने वाला नह_ हो।

युिFयाँ युिFयाँ: (1) Aयेक तरल भराव और तरल िनव हन लाइन म एक शट ऑफ वा]व पा के िजतना नजदीक स?भव को लगा होना चािहए। इस लाइन म मैनुअल शट औफ वा]व भी होना चािहए य+द वा]व हाथ से काम करने वाला नह_ हो।
(2) Aयेक तरल भराव और िनव हन लाइन म एक दूर थ िनयंित वयं ब<द होने वाला शट औफ वा]व यान पर होना
चािहए।
(3) Aयेक िनयंण वा]व, फेलसेफ (िडजाइन) वाला और yंग आधाOरत अवH य होना चािहए।
(4) Aयेक दूरथ िनयंित शट ऑफ वा]व म यांिक और तापीय ऑटोमैOटक बंद होने वाला यान पर दूर थ उपाय का उपबंध होना चािहए। (5) Aयेक दूरथ िनयंित शट ऑफ वा]व म यांिक और तापीय  वतः बंद होने वाला यान पर दूर थ साधन का उपबंध होना चािहए। एक साधन एक से अिधक दूरथ िनयंित वा]व को ब<द करने के िलए उपयोग +कया जा सकता है। वत: ब<दी के दूरथ साधन ट3कर के अि<तम छोर पर अिधYािपत होने चािहए, जो +क लदाई/उतराई संयोजन 7े से सवा िधक दूरी पर हो।

¹Hkkx IIµ[k.M 3(i)º 15 (छ)

ितबल

ितबल

ितबल

ितबल खंडः खंडः खंडः खंडः जब तक +क वा]व पीछे के केबीनेट म बंबर आगे अविथत न हो और ब?पर से संरि7त न हो, तब तक Aयेक वा]व का िडजाइन और अिधYापन िजसके 7ितuत होने के पOरणामवप =व या वाRप क! हािन हो सकती है, म वा]व के समीप थ और आउटबोड म ितबल या खांचे क! टूट-फूट समािवR ट होगा और ितबल खंड या खांचे क! टूट- फूट yखंचाव क! िथित म वा]व, िजससे =व या वाRप क! हािन हो, को कोई नुकसान पBँचाए िबना झुक जाएगा या टूट जाएगा।
(ज) अवलंब अवलंब अवलंब अवलंब और और और और ि7थरक ि7थरक ि7थरक ि7थरक:
य+द पOरवहन ट3कर इस कार अिभकि]पत और िन^म त है +क ट3क यान के ˜ेम से पूरी तरह अवलि?बत नह_ है, पOरवहन यान को बा„ उ=म या भार [रंzस )ारा अवलि?बत +कया जाना चािहए। अवल?बन, भार वहन करने वाले

7थरक ि7थरक:
य+द पOरवहन ट3कर इस कार अिभकि]पत और िन^म त है +क ट3क यान के ˜ेम से पूरी तरह अवलि?बत नह_ है, पOरवहन यान को बा„ उ=म या भार [रंzस )ारा अवलि?बत +कया जाना चािहए। अवल?बन, भार वहन करने वाले पा और अवल?बन संलिlय0 के िडजाइन गणना म एक इकाई के प म लदे यान के बीम का तनाव, िशयर तनाव, ¤ठन तना¥, वंकन 7ण और Aवरण तनाव आ+द शािमल +कया जाना चािहए । इसके िलए पदाथ के लचीले बल पर आधाOरत चार के सुर7ा कारक और थैितक लदाई, जब लदाई के िडजाइन भार तक भरा जाता है, पOरवहन पा के उपलlक0 के भार को उपयोग करता है, को शािमल +कया जाना चािहए । iि/गत प से <यूनतम थैितक लदाई िनrवत होनी चािहएः-

(i) 7ैितजीय नीचे क! ओर दो (2);

(ii) 7ैितजीय ऊपर क! ओर डेढ़ (1.5);

(iii) ल?बवत् डेढ़ (1.5); और

(iv) पा^v क डेढ़ (1.5) (झ)

मापक

मापक

मापक

मापक युिFयाँ युिFयाँ युिFयाँ युिFयाँ:
(क) =व सतह मापक युि/यां पा म एक =व सतह मापक युि/ होनी चािहए जो भरे से खाली तक लगातार सतह इंिगत करता रहे और िजसका, पा को हटाए िबना, रखरखाव और बदलाव +कया जा सके।
(ख) दाब मापक – Aयेक पा एक दाब मापक से सुसित हो जो अिधकतम =व तर के ऊपर +कसी िब<दु पर पा से जुड़ा Bआ हो िजसम टकर का अिधकतम अनुमAय काय शील दाब +कसी थाई िच¦न से इंिगत हो । दाब मापक ट3कर के केनोपी के अ<दर रखा जाना चािहए । ख ड ख ड ख ड ख ड 3

चालन

चालन

चालन

चालन, , , , अनुरण अनुरण अनुरण अनुरण और और और और िशण

िशण

िशण

य शील दाब +कसी थाई िच¦न से इंिगत हो । दाब मापक ट3कर के केनोपी के अ<दर रखा जाना चािहए । ख ड ख ड ख ड ख ड 3

चालन

चालन

चालन

चालन, , , , अनुरण अनुरण अनुरण अनुरण और और और और िशण

िशण

िशण

िशण क. Aयेक एलएनजी अिधYापन म चालन, रखरखाव और िश7ण क! काय िविधय0 का िलिखत म उपबंध होना चािहए। समप सुिवधा\ के gान, अनुभव के आधार पर ऐसी +Zया\ को तैयार +कया जाएगा। ख. Aयेक सं थापन िनrिलिखत अपे7ा\ के अनुप होना चािहए, अथा त्,:- (1) चालन, रखरखाव और िश7ण क! काय िविधय0 िलिखत म उपल2ध होनी चािहए। (2) संयं उप कर0 के अ तन आरेखण का अनुर7ण। (3) चालन िनयम पुितका के एक भाग के प म िलिखत आपातकालीन योजना। (4) पुिलस, अिlशमन िवभाग और वा§य ािधकारी जैसे थानीय ािधकाOरय0 के साथ स?पक म रहना चािहए और उनको आपातकालीन योजना और आपातकालीन पOरिथितय0 म उनक! भूिमका के बारे म सूिचत कराएँ।
(5) ऐसे दतावेज होने चािहए िजनम सुर7ा स?ब<धी किमयाँ िचि¦नत ह0 और उनके कारण0 का पता लगाने के योजन से उनका िव™ेषण +कया गया हो तथा उनके पुनरावृिE क! स?भावना को रोका जा सके।

16
[PART II—SEC. 3(i)]

ग.

चालन

चालन

चालन

िजनम सुर7ा स?ब<धी किमयाँ िचि¦नत ह0 और उनके कारण0 का पता लगाने के योजन से उनका िव™ेषण +कया गया हो तथा उनके पुनरावृिE क! स?भावना को रोका जा सके।

16
[PART II—SEC. 3(i)]

ग.

चालन

चालन

चालन

चालन कायMिविध कायMिविध कायMिविध कायMिविध िनयम िनयम िनयम िनयम पुि7तकाः पुि7तकाः पुि7तकाः पुि7तकाः Aयेक सं थापन म आपातकालीन काय िविधय0 के िलए एक िलिखत िनयम पुितका उपल2ध होगी िजसम स?भािवत आपात पOरिथितयाँ और िनrिलिखत काय िविधयां स? मिलत ह0गी, अथा त्:- (1) खोलने और ब<द करने क! काय िविध िजसम एलएनजी सुिवधा\ के ाथिमक शुआत भी शािमल हो। (2) पŸज ग और इन¨ट ग संघटक। (3) कूyलंग डाउन संघटक। (4) असामा<य िथितय0 क! स?भावनाएँ पहचानना। (5) सं थापन क! मर?मत या अनुसर7ण काय के दौरान अपेि7त सुर7ा पूवWपाय। (6) िनयंण योzय आपातकाल के िलए ित+Zया करने क! काय िविध िजसम का^म क0 को अिधसूिचत करना और उप कर0 का उपयोग, अथा त् - आपातकाल से िनपटने के िलए उपयु/, शािमल है। (7) +कसी अिनयंण योzय आपातिथित को gात करने क! काय िविध और यह सुिनिmत करने के िलए कार वाई करना +क पOरसर म मौजूद का^म क0 को तथा बाहर क! जनता को कम से कम 7ित हो। (8) आपातिथित के स?ब<ध म थानीय ािधकाOरय0 को तAकाल सूिचत करने क! काय िविध। (9) आपातिथित म जनता क! सुर7ा के िलए अपेि7त िनकास योजना तैयार करने म थानीय ािधकाOरय0 से सहयोग करने क! काय िविध। घ.

आपातिथित के स?ब<ध म थानीय ािधकाOरय0 को तAकाल सूिचत करने क! काय िविध। (9) आपातिथित म जनता क! सुर7ा के िलए अपेि7त िनकास योजना तैयार करने म थानीय ािधकाOरय0 से सहयोग करने क! काय िविध। घ. अनुरणः अनुरणः अनुरणः अनुरणः (1) Aयेक सं थापन म उपल2ध समान सुिवधा\ के अनुभव और gान के आधार पर तथा शत‰ के अधीन सं थापन म एक िलिखत काय िविध होनी चािहए। (2) यह सAयािपत करने के िलए +क उपकरण का रखरखाव उपकरण िविनमा ता\ क! िसफाOरश0 के अनुप +कया जा रहा है, +Zया म आविधक िनरी7ण +कए जाने क! आवH यकता, काय म यु/ Aयेक उपकरण और णाली क! जाँच को काय िविध म शािमल +कया जाए। (3) Aयेक अवयव, जो सं थापन का एक भाग है, क! जाँच और अनुर7ण के िलए िलिखत िनयम पुितका म iवथा होनी चािहए। िनरी7ण और जाँच के िलए काय Zम िनधा Oरत करने के अितOर/ . यि/य0 और संपिE क! भी सुर7ा सुिनिmत करने के िलए मर?मत काय के दौरान पालन क! जाने वाली काय िविध भी उसम शािमल क! जानी चािहए। ङ.

िशणः

िशणः

िशणः

िशणः Aयेक सं थापन का एक िश7ण योजना और उसे +कस कार काया ि<वत और अनुरि7त +कया जाएगा, का उपबंध होना चािहए। िश7ण िनयम पुितका म िनrिलिखत संघटक समािवR ट होने चािहए – (1) साधारण अवथा म सं थापन म यु;

Aयेक सं थापन का एक िश7ण योजना और उसे +कस कार काया ि<वत और अनुरि7त +कया जाएगा, का उपबंध होना चािहए। िश7ण िनयम पुितका म िनrिलिखत संघटक समािवR ट होने चािहए – (1) साधारण अवथा म सं थापन म यु; त क! जाने वाली मूलभूत चालन काय िविध। (2) स?बि<धत का^म क0 के िलए सं थापन म ©ूटी के दौरान आपातकालीन िथित से िनपटने क! काय िविधयां। (3) सुिवधा\ के चालन और अनुर7ण के दौरान एलएनजी के अिभल7ण और स?भािवत खतरे िजसम एलएनजी के स?पक म आने के पOरणामवप होने वाले शीतदंश के खतरे भी शािमल ह3। (4) चालन और रखरखाव रीित क! िनयम पुितका म िनधा Oरत चालन और अनुर7ण पpितय0 को काया ि<वत करने क! काय िविध। (5) एलएनजी अंतरण क! +Zया। (6) अिl से बचाव, िजसम सं थापन के अिl िनयंण योजना, अिlशमन, सुिवधा\ म आग लगने के स?भािवत कारण और सं थान म आग लगने से स?भािवत पOरणाम0 के कार और आकार। (7) उन पOरिथितय0 से मा< यता कराना िजनम सुिवधा\ क! सुर7ा कायम रखने के िलए सहयोग ा5 करना आवHयक हो।

¹Hkkx IIµ[k.M 3(i)º 17 ख ड ख ड ख ड ख ड 4

                           एलएनजी या एलसीएनजी िवतरण

एलएनजी या एलसीएनजी िवतरण एलएनजी या एलसीएनजी िवतरण एलएनजी या एलसीएनजी िवतरण इस अनुभाग म ऑटो एलएनजी िवतरण टेशन और एलसीएनजी सुिवधा\ के िलए आवHयकता\ क! जानकारी दी गई है। (क) साधारणः साधारणः साधारणः साधारणः
(1) एलएनजी Pधन भरण साइटे जो सेचुरेटेड एलएनजी के उपयोग या आसपास क^म य0 के साथ Pधन भरने वाले ऑपरेटर और यान क! र7ा के िलए अवरोध क! +दवारे या समान संर7ण दान करेगा। (2) यान म Pधन भरने के पाइप के अलावा अ<य सभी पाइyपंग सुिवधा अवरोध के िपछे रहेगी, जो उपकरण या युि/ क!

म य0 के साथ Pधन भरने वाले ऑपरेटर और यान क! र7ा के िलए अवरोध क! +दवारे या समान संर7ण दान करेगा। (2) यान म Pधन भरने के पाइप के अलावा अ<य सभी पाइyपंग सुिवधा अवरोध के िपछे रहेगी, जो उपकरण या युि/ क! खराबी क! दशा म सेचुरेटेड एलएनजी को उपर क! ओर मोड़ेगा। (ख)
णाली

णाली

णाली

णाली क क क क घटक घटक घटक घटक अहMताः अहMताः अहMताः अहMताः (1) यान Pधन िवतरक
(क) एलएनजी के िवतरण के िलए उपयोग +कए जाने वाले िवतरक का कार िविनदkश के अनुप होगा और मु$य िनयंक )ारा अनुमो+दत कार का होगा। (ख) िवतरक को यान क! ट£र क! 7ित से संरि7त +कया जाएगा। (ग) तरल आपू^त को रोकने और अंतरण उपकरण को बंद करने हेतु एक इएसडी उपल2 ध +कया जाएगा िजसम शट ऑफ वॉ] व शािमल होगा। (घ) िडपसर, पा उतराई सुिवधा और िबZ!/िनयंण क7 के पास एक इएसडी वत क (ए; चुएटर) क! iवथा क! जाएगी िजसके उपर आसानी से पहचान होने के िलए, साफ़ तौर पर थायी प से सुपा« हता7र िचपकाया जाएगा। (ङ) Pधन भरण नोझल पर अिधकतम िवतरण दाब, यान Pधन ट3क के अिधकतम वीकाय दाब से अिधक नह_ होगा। (च) (i) होज़ या आ? स को Pधन छोर पर शट् ऑफ वॉ] व और sेकअवे िडवाइस से सुसित +कया जाएगा ता+क होज़ के जुड़े रहने के समय यान ख_चते जाने क! िथित म =व और वाR प का कम से कम िनग मन हो।
(ii) ऐसे िडवाइस का सं थान और रखरखाव, ओइएम संघटक िविनमा ता अनुर7ण/ सुर7ा अनुदेश0 के अनुसार +कया जाएगा।
(iii) एक पृथकतावादी युि/ का ावधान कम से कम 102 +कलोuाम और 125 +कलोuाम से अनिधक बल का उपयोग करते Bए अलग करने के िलए, िजस +कसी +दशा िजसम यान जाएगा, +कया जाएगा ।
(छ) नली को नुकसान से बचाने के िलए जब उपयोग म नह_ तब संरि7त +कया जाएगा।

से कम 102 +कलोuाम और 125 +कलोuाम से अनिधक बल का उपयोग करते Bए अलग करने के िलए, िजस +कसी +दशा िजसम यान जाएगा, +कया जाएगा ।
(छ) नली को नुकसान से बचाने के िलए जब उपयोग म नह_ तब संरि7त +कया जाएगा। (ज) (i) जहां =व अंतरण हेतु नाममा 76 िममी iास या बड़े होज़ या आ?स का उपयोग +कया गया, या जहां वाR प अंतरण हेतु नाममा 100 िममी iास या बड़े का उपयोग +कया गया है, तो िनकटतम होज़ या आ?स से 3.1 मीटर के भीतर अंतरण णाली के पाइyपंग म आपातकालीन शट ऑफ वा] व अिधR ठािपत +कया जाएगा।
(ii) जहां वाह होज से दूर है, ऐसे म शट ऑफ वा]व के प म एक जाँच वा]व के उपयोग क! अनुमित दी जाएगी।
(iii) जहां =व या वाR प लाईन म से +कसी को दो या दो से अिधक पैर है तो ऐसे म एक आपातकालीन शटऑफ वा]व या तो एक पैर म या फ़!ड लाइन म पैर0 के सामने थािपत +कया जाएगा।
(झ) ओइएम िविनमा ता\ के िनदkश0 को िवतरक के पास लगाया। (ञ) अविथित और आपातकालीन िनयंण के संचालन क! पहचान कर सुिवधा 7े म सुपVता से ऑपरे[टंग िनदkश लगाए जाएंगे। (ट) एलएनजी Pधन भरण सुिवधा, जहां रात के दौरान एलएनजी का अंतरण +कया जाता है, वहां अंतरण और चालन  थल पर पया 5  थायी काश iवथा रखी जाएगी।

कर सुिवधा 7े म सुपVता से ऑपरे[टंग िनदkश लगाए जाएंगे। (ट) एलएनजी Pधन भरण सुिवधा, जहां रात के दौरान एलएनजी का अंतरण +कया जाता है, वहां अंतरण और चालन  थल पर पया 5  थायी काश iवथा रखी जाएगी।

18
[PART II—SEC. 3(i)]

(ठ) यान ऑनबोड एलएनजी कंटेनर0 म एलएनजी का अंतरण ऑनबोड एलएनजी कंटेनर और Pधन भरण घटक ओइएम िविनमा ता अनुदेश0 के अनुसार +कया जाएगा। (2) यान Oधन योजक (वेिहकल Qयु#लंग कनेI ट यान Oधन योजक (वेिहकल Qयु#लंग कनेI ट यान Oधन योजक (वेिहकल Qयु#लंग कनेI ट यान Oधन योजक (वेिहकल Qयु#लंग कनेI टर) र)र) र): (क) एलएनजी या गैस वाRप का यान म या यान से िवvसनीय और सुरि7त अंतरण के िलए Pधन कने;टर और मे[टंग वेिहकल Oरिस> टेकल (मे[टंग यान गोदाम) का उपयोग +कया जाएगा। (ख) Pधन भरण कने;टर या तो इंटरलॉक िडवाइस से सुसित +कया जाएगा, जो लाइन खुली रहने पर बहाव को रोके या  वयं बंद होने वाला हो जो िवयोजन होने पर  वचािलत प से बंद होता हो। (3) आपातकालीन आपातकालीन आपातकालीन आपातकालीन बंद होने वाले उप7 क बंद होने वाले उप7 क बंद होने वाले उप7 क बंद होने वाले उप7 कर र र र क 7थापना (ईएसडी): क 7थापना (ईएसडी): क 7थापना (ईएसडी): क 7थापना (ईएसडी): (क) ईएसडी, पOर7ेपण, एलएनजी उताराई सुिवधा और िबZ! या िनयंण क7 के पास उपल2ध कराया जाएगा। (ख) एलएनजी Pधन भरण सुिवधा के िलए यंीकरण (इं­मटेशन) इस कार से िडजाईन +कया जाएगा +क
पावर या यंीकरण क! िवफलता क! िथित म चालक0 )ारा पुनः स+Zय करने तक या शटडाउन होने तक, फेलसेफ दशा म चला जाए। (ग) सभी इएसडी को हाथ से (मैनुअली) रीसेट +कया जाएगा।

खंड 5 खंड 5 खंड 5 खंड 5 एलएनजी एलएनजी एलएनजी एलएनजी या या या या एलसीएनजी एलसीएनजी एलसीएनजी

ली) रीसेट +कया जाएगा।

खंड 5 खंड 5 खंड 5 खंड 5 एलएनजी एलएनजी एलएनजी एलएनजी या या या या एलसीएनजी एलसीएनजी एलसीएनजी एलसीएनजी 7टेशन: म गैर Oधन भरने क 7टेशन: म गैर Oधन भरने क 7टेशन: म गैर Oधन भरने क 7टेशन: म गैर Oधन भरने क सुिवधाएं सुिवधाएं सुिवधाएं सुिवधाएं छोटे सुिवधा टोर, स^व स टेशन, एटीएम, पीसीओ, जैसे गैर Pधन भरण सुिवधा\ का ावधान जब भी +कया जाएगा, इस अनुसूची म व^ण त सुर7ा दूरी के आगे होगा। इसके अलावा एलएनजी/ एलसीएनजी पOर7ेपक0 से 10 मीटर क! <यूनतम दूरी बनाई रखी जाएगी। इस तरह के गैर Pधन भरण सुिवधा\ म पBंच, पOरचालन 7े से नह_ होगी। ऐसी सुिवधाए उपल2 ध कराते समय, आपात क! िथित म, पOरसर म अिधक भीड़ क! माा, Pधन भरने आने वाले यान के आसान वेश और िनग म और एलएनजी रोड ट3कर का पOरसर से बाहर िनकास म गितशीलता लानेजैसे कारक0 को भी यान म रखा जाएगा।

खंड 6 खंड 6 खंड 6 खंड 6 संेपण गैस बंधन संेपण गैस बंधन संेपण गैस बंधन संेपण गैस बंधन (बाइल ऑफ गैस मैनेजमट) (बाइल ऑफ गैस मैनेजमट) (बाइल ऑफ गैस मैनेजमट) (बाइल ऑफ गैस मैनेजमट) जब एलएनजी टेशन सं थािपत +कया जाए तब बीओजी व[टंग को कम करने के िलए भंडारण ट3क क! 7मता अनुकूिलत क! जाए। बीओजी के भावी बंधन के िलए मु$य िनयंक के अनुमोदन से ऑपरेटर )ारा व[टंग रोकने के िलए गैस का उपयोग +कया जा सकता है। खंड 7 खंड 7 खंड 7 खंड 7 ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टेशन सं7 था शन सं7 था शन सं7 था शन सं7 थापक पक पक पक क क क क मा य मा य मा य मा यता ता ता ता क.

सकता है। खंड 7 खंड 7 खंड 7 खंड 7 ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टे ऑटो एलएनजी 7 टेशन सं7 था शन सं7 था शन सं7 था शन सं7 थापक पक पक पक क क क क मा य मा य मा य मा यता ता ता ता क. एलसीएनजी/ ऑटो एलएनजी िवतरण टेशन थािपत करने क! इ‹छुक कंपनी )ारा मु$य िनयंक )ारा मा<यता पर िवचार करने के िलए िनrिलिखत मानदंड0 को पूरा करना होगा - (i) मािलकाना फम या साझेदारी फम या ाइवेट िलिमटेड कंपनी या िलिमटेड कंपनी;
(ii)  थापना काय के काय िनRपादन हेतु पया 5 उपकरण और मशीनरी क! उपल2 धता; (iii) आईएसओ माणीकरण से यु; त होना,
(iv) िन? निलिखत म पया 5 प से िनपुण िवशेषgो क! उपल2 धता-

¹Hkkx IIµ[k.M 3(i)º 19 (क) एलसीएनजी या ऑटो एलएनजी उप कर, उनके संचालन, रखरखाव और क^म य0 के िश7ण क! थापना। (ख) एलसीएनजी या ऑटो एलएनजी िविनयम0 और जुड़े खतरे। (ग) एलसीएनजी/ ऑटो एलएनजी टेशन0 क! थापना से संबंिधत संिहताएं। (घ) काय के िनRपादन के िलए जहां तक सुसंगत हो आरेखण और योजना\ का िववेचन; (v) फम या कंपनी )ारा लगाए गए ऐसी क^म य0 क! सं$या, जाने वाले  तािवत टेशन0 क! सं$ या के अनु प होगी; (vi) . यावसाियक, शासिनक और . यव थापन क! ाि5 िज? मेदारी के  पR ट  तर के उA तरदाियA व के साथ (vii) अपने क^म य0 के iावसाियक कौशल के िलए उA तरदाियA व; (viii)  टेशन0 के संचालन, आविधक रखरखाव और खराबी म रखरखाव का उA तरदाियA व लेना और इस संबंध म िविनUद R ट अविध के िलए अपने डीलर0 के साथ कानूनी समझौता करना; ख. एलसीएनजी या ऑटो एलएनजी सं7 था एलसीएनजी या ऑटो एलएनजी सं7 था एलसीएनजी या ऑटो एलएनजी सं7 था एलसीएनजी या ऑटो एलएनजी सं7 थापक पक पक पक को को को को मायता मायता मायता मायता जारी जारी जारी जारी करने करने करने करने क क क क <या

<या

<या

ऑटो एलएनजी सं7 था एलसीएनजी या ऑटो एलएनजी सं7 था एलसीएनजी या ऑटो एलएनजी सं7 थापक पक पक पक को को को को मायता मायता मायता मायता जारी जारी जारी जारी करने करने करने करने क क क क <या

<या

<या

<या.- (i) +कसी भी संगठन को एलसीएनजी या ऑटो एलएनजी के प म मा<यता ा5 करने के िलए एससीएनजी ऑटो एलपीजी िवतरण टेशन के सं थापन और अनुर7ण 7े म अपने अनुभव के संबंध म कंपनी के Aयय- प का िववरण देते Bए सं थापक आवेदन, मु$य िनयंक को तुत करना होगा।
(ii) Aयेक आवेदन के साथ अनुसूची-1 के भाग (ख) म यथा िविनUद R ट संवी7ा शु]क संलl होनी चािहए। (iii) मु$य िनयंक ऐसे आवेदन क! ाि5 तारीख से न2 बे +दन0 के अ<दर या – (क) थम दृVया, एलसीएनजी/ऑटो एलएनजी के प म, आवेदक को मा<यता दान करने के िलए, स7मता और iावसाियक आचार नीित के स?ब<ध म वयं समाधानद होने पर, आवेदक का तकनीक! और iावहाOरक gान और स7मता जाँच करने के िलए मु$य िनयंक )ारा नामिनUद R ट अिधकाOरय0 के दल )ारा सा7ाAकार हेतु आवेदक को उसके तकनीक! दल के साथ बुलाना चािहए; या (ख) य+द थम दृVया आवेदक मा<यता क! अपे7ा\ पर खरा नह_ उतरता है तो आवेदन को कारण0 सिहत अवीकार कर देना चािहए;

R ट अिधकाOरय0 के दल )ारा सा7ाAकार हेतु आवेदक को उसके तकनीक! दल के साथ बुलाना चािहए; या (ख) य+द थम दृVया आवेदक मा<यता क! अपे7ा\ पर खरा नह_ उतरता है तो आवेदन को कारण0 सिहत अवीकार कर देना चािहए; या (iv) (क) य+द इस िनयम म संचािलत सा7ाAकार म आवेदक म मा<यता हेतु पया 5 gान और स7मता पाई जाती है तो मु$य िनयंक )ारा िनयम के अधीन मा<यता दान कर दी जाएगी। (ख) य+द कोई आवेदक उिचत नह_ पाया जाता है तो मु$य िनयंक )ारा कारण बताते Bए आवेदन को अवीकार कर +दया जाएगा ।
(v)
ारि?भक तौर पर खंड (iv) के अधीन जारी स7मता एक वष क! अविध के िलए िविधमा< य रहेगी । तAपmात् काय िनRपादन Oरपोट के आधार पर दो वष के िलए पुन^व िधमा< य +कया जा सकता है। (vi) मु$य िनयंक थापनाकता को जारी क! गई मा< यता को ितसंnत या िनलंिबत कर सकते है य+द थापनाकता अनुसूची म व^ण त दाियAव0 को पूण नह_ करता। (vii) मु$य िनयंक )ारा सं थापक को सुने जाने का एक अवसर देने के पmात् मा<यता ितसंnत क! जा सकती है– (क) य+द उनके पास यह मानने का पया 5 कारण है +क यथािथित, सं थापक )ारा मा<यता प म उि]लिखत +कसी शत का उ]लंघन +कया गया है या उनके )ारा इन िनयम0 के योजन या आशय के असंगत कोई िनरी7ण, जाँच, परी7ण +कया गया है या ऐसा काय +कया गया है; या (ख) कोई अ<य कारण, जो लेखबp +कया जाए।

<यता प म उि]लिखत +कसी शत का उ]लंघन +कया गया है या उनके )ारा इन िनयम0 के योजन या आशय के असंगत कोई िनरी7ण, जाँच, परी7ण +कया गया है या ऐसा काय +कया गया है; या (ख) कोई अ<य कारण, जो लेखबp +कया जाए।

20
[PART II—SEC. 3(i)]

खंड 8 खंड 8 खंड 8 खंड 8 आपातकालीन आपातकालीन आपातकालीन आपातकालीन योजना योजना योजना योजना

A येक एलएनजी या ऑटो एलएनजी िवतरण टेशन म गंभीर एलएनजी Oरसाव या आग से खतर0 को िनयंित करने के िलए िलिखत प म आपात योजना होनी चािहए। योजना, थानीय ािधकाOरय0 अथा त् अिlशामक सेवा\ के साथ परामश कर बनाई जाएगी। इस योजना म, टेशन को आपातकालीन िथित म बंद करने के िनदkश, uाहक0 को और आसपास के अ<य लोग0 के िलए चेतावनी, सहायता के िलए कॉल, अ< य लोग0 के िलए अिlशमन उपकरण0 का उपयोग, शािमल ह0गे। उसक! पया 5ता के मू]यांकन हेतु योजना का समय-समय पर परी7ण +कया जाएगा और यथा आवHयक उसे अ तन और संशोिधत +कया जाएगा”। 12. उ; त िनयम0 म “प एल एस- 1 ख” के पH चात् िन? निलिखत प अंतः थािपत +कया जाएगा, अथा त्:-
“ Tप

Tप

Tप

Tप एल एल एल एल एस एस एस एस – 1ग ” (िनयम 50, 51, 54 और िनयम 55 देख) ऑटो ऑटो ऑटो ऑटो एलएनजी एलएनजी एलएनजी एलएनजी प'रेपण प'रेपण प'रेपण प'रेपण 7टेशन 7टेशन 7टेशन 7टेशन मेमेमेमे ऑटोमो'टव ऑटोमो'टव ऑटोमो'टव ऑटोमो'टव Oधन Oधन Oधन Oधन केकेकेके Tप Tप Tप Tप मेमेमेमे मोटर मोटर मोटर मोटर यानो यानो यानो यानो मेमेमेमे ऑटो ऑटो ऑटो ऑटो एलएनजी एलएनजी एलएनजी एलएनजी केकेकेके प'रेपण प'रेपण प'रेपण प'रेपण और और और और भ डारण भ डारण भ डारण भ डारण केकेकेके िलए िलए िलए िलए अनुि अनुि अनुि अनुि अनुgि5 सं$ या ............................... फ!स……………. #पए

›ी .............................................

ारण केकेकेके िलए िलए िलए िलए अनुि अनुि अनुि अनुि अनुgि5 सं$ या ............................... फ!स……………. #पए

›ी ............................................. को िनम् न व^ण त पOरसर मे नीचे उपद^श त दाबपा0 esa ऑटो एलएनजी के भंडारण और ऑटोमोOटव Pधन के प esa मोटर यान0 esa ऑटो एलएनजी/ एलसीएनजी के पOर7ेपण के िलए, भारतीय िव फोटक अिधिनयम, 1884 (1884 का 4) और उसके अधीन बनाए गए िनयम0 के उपबंध0 और इस अनुgि5 म दी गई शत‰ के अधीन और अनुgि5 मंजूर क! जाती है। पा सं$या घन मीटर esa जलधाOरता
मंजूर ऑटो एलपीजी क! माा +कलोuाम म

यह अनुgि5 तारीख 30 िसत?बर 20.......... तक िविधमा< य रहेगी। जारी करने क! तारीख………………………20 मु$ य िव फोटक िनयंक / िवफोटक िनयंक अनु अनु अनु अनु प'रसर प'रसर प'रसर प'रसर क क क क अवि7थित अवि7थित अवि7थित अवि7थित और और और और सुिवधाU सुिवधाU सुिवधाU सुिवधाU का का का का वणMन वणMन वणMन वणMन

अनुg5 पOरसर, लेआउट, चहरदीवाल और अ<य िविशिVयां जो +क संलl अनुमो+दत >लान सं$या ....................................................... तारीख ....................... मे दशा या गया है ...............................................................................................................

................................. तारीख ....................... मे दशा या गया है ............................................................................................................... ( पता ) म िथत है और उसम ...............................................................(उ/ उि]लिखत भंडारण पा0 के अलावा) ह3 – (i) …………िवतरक सं$या ............................मेक (ii) अ<य सुिवधाएं नवीकरण नवीकरण नवीकरण नवीकरण पृ+ांकन पृ+ांकन पृ+ांकन पृ+ांकन केकेकेके िलए िलए िलए िलए 7थान 7थान 7थान 7थान िव फोटक अिधिनयम, 1884 या उसके अधीन बनाए गए िथर और गितशील दाबपा (अ¯विलत) िनयम 2016 के उपबंध0 या इस अनुgि5 म दी गई शतW का उ]लंघन ना होने क! िथित म फ!स म कोई छूट +दए िबना अनुgि5 पांच वष के िलए नवीकरणीय होगी।
नवीकरण तारीख अवसान क! तारीख अनुgि5 ािधकारी के हता7र और काया लय मुहर

¹Hkkx IIµ[k.M 3(i)º 21 य+द अनुg> त पOरसर िववरण और संलl शत‰ के अनुसार नह_ पाया जाता है या िजन िनयम0 या शत‰ के अधीन यह अनुgि5 मंजूर क! गई है उनम से +कसी का उ] लंघन होता है तो अनुgि5 र° क! जा सकती है और अनुgि5धारी अिधिनयम के अधीन दJ डनीय होगा।

शतW शतW शतW शतW

  1. अनुg5 पOरसर अविथित के िववरण और सुिवधा\ तथा अनुgि5 के मुख पृY पर उि]लिखत अनुमो+दत योजना के 
    

अनुप होना चािहए। 2. अनुgि5 िजस योजन से जारी क! गई है, अनुg5 पOरसर का उपयोग उसी के िलए +कया जाएगा। 3. इन िनयम0 के अधीन Aयेक अनुg5 पOरसर म उसक! अनुgि5 सं$या मुखता से िचि¦नत होनी चािहए। 4. थानीय अिlशमन काया लय, पुिलस और धान िवपणन क?पनी या स?पीिडत गैस के आपू^त कता के आपातकालीन दूरभाष सं$या और आपातकालीन िनदkश0 को अनुg5 पOरसर मे सहज दृHय थान पर द^श त +कया जाना चािहए। 5.

चािहए। 4. थानीय अिlशमन काया लय, पुिलस और धान िवपणन क?पनी या स?पीिडत गैस के आपू^त कता के आपातकालीन दूरभाष सं$या और आपातकालीन िनदkश0 को अनुg5 पOरसर मे सहज दृHय थान पर द^श त +कया जाना चािहए। 5. इन िनयम0 के उपाबंध0 के अधीन ऑटो एलएनजी का भJडारण एक या एक से अिधक सं थािपत भूमोपOर दाबपा0 म +कया जाना चािहए। 6. भJडारण पा, िडपसर, प?प, क?ेशर, पाइyपंग और अ<य +फ[टंग ऑटो एलएनजी के िलए उपयु/ अिभक]पना
(िडजाइन) के अनुसार होने चािहए। 7. भJडारण पा +कसी भवन या शेड के भीतर सं थािपत नह_ होने चािहए। 8. भJडारण पा0 म ऑटो एलएनजी के िबना लदाई के िलए ट3क Xक क! पा±क  ग के िलए िनयमानुसार हाड टैJड का उपबंध +कया जाना चािहए। 9. अनुसूची IV म िविनUद V अपे7ानुसार अनुg5 पOरसर मे सुिवधा\ और उपकरण0 म उिचत सुर7ा दूरी का उपबंध होना चािहए। 10. ऑटो एलएनजी का पOर7ेपण मोटर यान के केवल उन पा0 म करना चािहए जो मु$य िनयंक )ारा अनुमो+दत ह0 और जो मु$य िनयंक )ारा मा<यताा5 परी7ण टेशन म गैस िसेलेJडर िनयम0 के अधीन आविधक कानूनी परी7ण पास कर चुके ह0। 11. ऑटो एलएनजी के पOर7ेपण हेतु उपयोग +कया जाने वाला िडपसर अनुसूची–4 के अनुप और मु$य िनयंक )ारा अनुमो+दत िविनदkश0 के अनुसार होना चािहए। 12. सभी पाइyपंग और +फ[टंग अनुसूची – 4 के अनुप होनी चािहए। 13. कोई भी . यि/, वलनशील गैस के भJ डारण के िलए उपयोग मे लाए जाने वाले पा म, मर? मत, न तो अिl के उपयोग )ारा वेy]डंग, झलाई करके Oरबेट लगाएगा न पीतल से झालने का काम करेगा जब तक +क यह पूण त: साफ और गैस से मु; त नह_ कर िलया जाता या अ< यथा सुर7ापूण त> त काय +कए जाने के िलए तैयार होने के स?ब<ध म स7म iि/ )ारा िलिखत म मािणत नह_ कर +दया जाए। 14.

ल से झालने का काम करेगा जब तक +क यह पूण त: साफ और गैस से मु; त नह_ कर िलया जाता या अ< यथा सुर7ापूण त> त काय +कए जाने के िलए तैयार होने के स?ब<ध म स7म iि/ )ारा िलिखत म मािणत नह_ कर +दया जाए। 14. अनुg5 पOरसर का चालन +कसी ऐसे iि/ के अधीन होना चािहए िजसे पOरसर म यु/ उपकरण0 का पूण gान हो और एलएनजी के रखरखाव म िशि7त हो और अ<य चालक संपीिड़त गैस से जुड़े पOरसंकट0 से gात ह0 और अिlशमन यं0 के उपयोग क! जानकारी रखते ह0। 15. अनुgि5 के साथ संलl अनुमो+दत योजना म दशा ए गए अंतरण सुिवधा\ के अितOर/ अ<य +कसी मायम से ऑटो एलएनजी पा म भरा या पा से िनकाला नह_ जाना चािहए। 16. पOरसर के अ<दर धू²पान, खुली रोशनी, लै?प, अिl के ोत या वलनशील वाRप म अिl उAप~ करने का कोई ेरक ोत अनुgात नह_ होना चािहए। ब<धन म लगे या िनयु/ अथवा अनुg5 पOरसर से स?बि<धत Aयेक iि/ को ऐसे +कसी भी काय से बचना चािहए िजससे अिl या िवफोटक उAप~ हो और यथोिचत आवHयक न हो और अपनी जानकारी म +कसी अ<य iि/ को भी ऐसा कोई काय करने से रोकना चािहए। 17. पा, मु$ य िव फोटक िनयंक के अनुमित के िबना सूया त और सूयWदय के मय नह_ भरा जाएगा। 18. एनएनजी के अंतरण के उपयोग के िलए सभी मोटर िवच, टाटस आ+द सभी िव ुत उपकरण आईएस/आईईसी 60079-1 से 11 तक के अनुप वालासह कार का या मु$य िनयंक )ारा अनुमो+दत कार का होना चािहए।

नह_ भरा जाएगा। 18. एनएनजी के अंतरण के उपयोग के िलए सभी मोटर िवच, टाटस आ+द सभी िव ुत उपकरण आईएस/आईईसी 60079-1 से 11 तक के अनुप वालासह कार का या मु$य िनयंक )ारा अनुमो+दत कार का होना चािहए।

22
[PART II—SEC. 3(i)]

ट3क Xक िबनालदाई 7े के समीप कम से कम दो, नौ +क० uा० 7मता के xाई रसायिनक कार के अिlशामक यं0 का उपबंध होना चािहए और एक इसी कार का अिlशामक यं Aयेक िडपे<सर और Xा<सफर प?प के समीप उपल2ध होना चािहए। इसके अितOर/ अनुसूची–4 म िविनUद V अिlशामक सुिवधा\ का भी उपबंध करना चािहए। 20. ट3क Xक से भJडारण पा म एनएनजी क! उतराई क! अविध म, यान0 म िडपेy<संग काय नह_ करना चािहए। 21.  थानीय अिlशमन टेिलफोन नंबर पर काया लय पुिलस और धान िवपणन कंपनी और अपातकालीन िनदkश0 के अनुgापन पOरसर म सहज ³H य  थान पर द^श त +कया जाना चािहए।
22. पOरसर म पा के सभी वा].स और पाइyपंग म आंरभ और बंद क! +दशा को उपद^श त करते Bए थाई प से िचि¦नत +कया जाना चािहए। 23. िनयम 70 म िविनUद R ट +कसी भी अिधकारी को, सभी सुसंगत समय पर अनुg5 पOरसर म वेश करने +दया जाएगा और उ/ अिधकारी को यह सुिनिmत करने के िलए +क िनयम0 और शत‰ का स? यक पालन हो रहा है, सभी सुिवधाएं दी जाएंगी। 24. य+द अनुgि5 ािधकारी अनुgि5धारी को िलिखत मे अनुg5 पOरसर म कोई मर?मत काय करने क! सूचना देते ह3, जो उनक! राय मे पOरसर क! सुर7ा हेतु आवHयक है, नोOटस म उि]लिखत समयाविध मे अनुgि5धारी को उ/ मर?मत काय पूण करना होगा। 25. अनुg5 पOरसर के भीतर अिl या िव फोट से होने वाली दुघ टना या +कसी अघटन क! तA काल सूचना मु$य िनयंक, िनयंक, िनकटतम पुिलस टेशन और िजला मिजXेट को संचार के सवा िधक तेज़ मायम से देना होगा।”
[फा. सं.

अनुg5 पOरसर के भीतर अिl या िव फोट से होने वाली दुघ टना या +कसी अघटन क! तA काल सूचना मु$य िनयंक, िनयंक, िनकटतम पुिलस टेशन और िजला मिजXेट को संचार के सवा िधक तेज़ मायम से देना होगा।”
[फा. सं. 2(1)/2017-िव फो.]
शैले< = yसंह, अितOर/ सिचव

'ट प 'ट प 'ट प 'ट पण: मूल िनयम भारत के राजप, असाधारण, भाग II खंड 3, उपखंड (i) म अिधसूचना सं. सा.का.िन.1109(अ) )ारा तारीख 1 +दसंबर, 2016 को कािशत +कए गए थे।

MINISTRY OF COMMERCE AND INDUSTRY (Department of Industrial Policy and Promotion) NOTIFICATION New Delhi, the 20th April, 2018 G.S.R. 388 (E).— WHEREAS, the draft rules to amend the Static and Mobile Pressure Vessels (Unfired) Rules, 2016, was published, vide Notification of the Government of India in the Ministry of Commerce and Industry (Department of Industrial Policy and Promotion), number, G.S.R. 887 (E), dated the 17th July, 2017 in the Gazette of India, Extra-ordinary, Part-II, Section 3, Sub section (i), inviting objections or suggestions from all persons likely to be affected thereby before the expiry of forty five days from the date on which the notification was made available to the public; AND WHEREAS, the said notification was made available to the public on the 17th July, 2017; AND WHEREAS, objection and suggestions received from the public on the said draft rules have been duly considered by the Central Government;

was made available to the public on the 17th July, 2017; AND WHEREAS, objection and suggestions received from the public on the said draft rules have been duly considered by the Central Government; NOW THEREFORE, in exercise of the powers conferred by sections 5 and 7 of the Explosives Act, 1884 (4 of 1884), the Central Government thereby makes the following rules to amend the Static and Mobile Pressure Vessels (Unfired) Rules, 2016, namely: -
1.
Short title and commencement (1).- These rules may be called the Static and Mobile Pressure Vessels (Unfired) (Amendment) Rules, 2018. (2) They shall come into force on the date of their publication in the Official Gazette.

¹Hkkx IIµ[k.M 3(i)º 23

In the Static and Mobile Pressure Vessels (Unfired) Rules, 2016, (hereinafter referred to as the said rules), in rule 2,-

(a) after clause (iii), the following clause shall be inserted, namely:-

‘(iiia) "Auto LNG" means a liquefied natural gas for automotive fuel;’;

(b) after clause (iv), the following clause shall be inserted, namely:-

‘(iva) “Auto LNG dispensing station” means a premises used for storing and dispensing auto LNG as automotive fuel to the motor vehicles;’; (c) after clause (v), the following clause shall be inserted, namely:-

‘(va) “Auto LNG or LCNG dispensing installer” means a company recognised by the Chief Controller for installation and maintenance of Auto LNG or LCNG dispensing station having qualification and experience specified in Schedule IV;’;

installer” means a company recognised by the Chief Controller for installation and maintenance of Auto LNG or LCNG dispensing station having qualification and experience specified in Schedule IV;’; (d) in clause (xiv), for the words “thermosyphon tanks and includes”, the words “thermosyphon tanks including” shall be substituted; (e) in clause (xv), after the words “liquefied petroleum gas (LPG) container”, the words “or liquefied natural gas (LNG) container” shall be inserted;

(f) for clause (xviii), the following clause shall be substituted, namely:-

‘(xviii) “dispenser” means an equipment installed in liquefied petroleum gas dispensing station or liquefied natural gas dispensing station, as the case may be, meant for dispensing liquefied petroleum gas or liquefied natural gas as automotive fuel to motor vehicles;’; (g) for the clause [xxxi(a)], the following clauses shall be substituted, namely:-

‘(xxxia) “liquefied natural gas (LNG)" means a fluid in the cryogenic liquid state composed
predominantly of methane;

(xxxib) "LCNG" means CNG produced at the fueling station from LNG by
pumping and vapourisation.

In the said rules, for rule 29, the following rule shall be substituted, namely:-

“29.

xxxib) "LCNG" means CNG produced at the fueling station from LNG by
pumping and vapourisation.

In the said rules, for rule 29, the following rule shall be substituted, namely:-

“29. Dispenser for auto LPG or auto LNG dispensing station.- The dispenser and connected fittings used for dispensing auto LPG or auto LNG in motor vehicles provided in the auto LPG or auto LNG dispensing station shall be designed, constructed, tested and maintained in accordance with the requirements laid down in Schedule II or Schedule IV of these rules, as the case may be, and be of a type approved in writing by the Chief Controller.” 4.
In the said rules, for rule 30, the following rule shall be substituted, namely:-

         “30. 

Special Provisions for filling fuel tanks of motor vehicles and unloading of tank-truck in auto LPG or auto LNG dispensing station.– (1) Auto LPG or Auto LNG shall not be filled in fuel tank of motor vehicle while the engine of the vehicle is running.

(2) During the period of unloading of Auto LPG or Auto LNG from tank-truck to the storage vessels, operation of dispensing Auto LPG or Auto LNG to motor vehicles shall not be carried out.”

In the said rules, in rule 49, in sub-rule (4), after the letters and figure "LS-1B", the letters and figure "LS-1C" shall be inserted.

LNG to motor vehicles shall not be carried out.”

In the said rules, in rule 49, in sub-rule (4), after the letters and figure "LS-1B", the letters and figure "LS-1C" shall be inserted.

In the said rules, in rule 50, in clause (i), in sub-clause (a), after the words and letters “and dispense Auto LPG as automotive fuel”, the words, letters and figure “and Form LS-1C to store and dispense Auto LNG as automotive fuel” shall be inserted.

In the said rules, in rule 51, in sub-rule (1), after the letters and figure “LS-1B”, the letters and figure “or LS- 1C” shall be inserted.

24
[PART II—SEC. 3(i)]

In the said rules, in rule 55, in sub-rule (2), after the letters and figure “LS-1B”, the letters and figure “LS-1C” shall be inserted.

In the said rules, in Schedule-I, -

(a) in Part A, in the table, “Sl. No. 3” and the entries relating thereto shall be renumbered as “Sl. No. 4” thereof and before the “Sl. No. 4” as so renumbered, the following Sl. No. and entry shall be inserted, namely :-

“3. LS-1C To store and dispense auto-LNG in auto-LNG dispensing station as automotive fuel to motor vehicles and/or store LNG in connection with LCNG dispensing. Chief Controller or Controller authorised by him. Same as the licence in Form LS-1A”;

(b) for Part B, the following Part shall substituted, namely:-

“B:
Fee other than licence fee

Sl. No. Purpose
Fees
(In rupees) 1. Approval or renewal of shop approval to manufacture pressure vessel, vapouriser and fittings under rule 4 (3) (i) and (ii).

Fee other than licence fee

Sl. No. Purpose
Fees
(In rupees) 1. Approval or renewal of shop approval to manufacture pressure vessel, vapouriser and fittings under rule 4 (3) (i) and (ii). 5000/- per year 2. Approval of design drawing of pressure vessel, vapouriser & fittings under rule 4(3) (iii). 2500/- 3. Import of pressure vessel under rule 4(5). 5000/- 4. Repairing of pressure vessel under rule 6. 2500/-
5. Recognition/Revalidation of competent person/inspector under rule 12. 5000/- per year
6. Approval of vehicle mounting drawing for transport of compressed gas under rule 35(2). 2000/- 7. Prior approval of specification and plans of vessels and premises under rule 46. 2000/- 8. Issue of authenticated copy of licence under rule 49(3). 1000/- 9. Prior approval of alternation in the licensed premises under rule 53(2). 2000/- 10. Amendment of licence under rule 54(1). 1000/- 11. Transfer of licence under rule 54(2). 1000/- 12. Issue of new licence in case of death or disability of licensee under rule 60(2). 1000/- 13. Issue of duplicate copy of licence under rule 61. 1000/- 14 Grant / renewal of recognition for installer/operator as mentioned in Schedule –II and IV 5000/- per year.”

(2). 1000/- 13. Issue of duplicate copy of licence under rule 61. 1000/- 14 Grant / renewal of recognition for installer/operator as mentioned in Schedule –II and IV 5000/- per year.”

In the said rules, in the Schedule II, after clause (M), the following clause shall be inserted, namely: -

“(MA) Procedure for granting recognition to Auto LPG operator:

(i) Any organisation intending to be recognised as Auto LPG operator shall submit their application giving details of company’s credentials with regard to their experience in the field of management and operation of Auto LPG dispensing station to the Chief Controller of Explosives.
(ii) Every such application shall be accompanied by a scrutiny fee as specified in Part B of Schedule I.
(iii) The Chief Controller shall within a period of ninety days from the date of receipt of the application either–

¹Hkkx IIµ[k.M 3(i)º 25 (a) prima facie after having satisfied himself with regard to competence and professional ethics, for recognition of the applicant as a Auto LPG dispensing station operator, shall call the applicant along with his technical team for an interview by a team of officers nominated by the Chief Controller for assessing the technical and practical knowledge and capability of the applicant; or
(b) if the applicant does not prima facie meet the requirement for recognition, shall reject the application with reasons;

he technical and practical knowledge and capability of the applicant; or
(b) if the applicant does not prima facie meet the requirement for recognition, shall reject the application with reasons; or (iv) (a) if the applicant in the interview conducted under this rule is found to have adequate knowledge and capability for the recognition applied for, the Chief Controller shall grant the recognition under the rules; or (b) in case any applicant is not found suitable, the Chief Controller shall reject the application specifying the reasons.
(v) Initially the recognition granted under sub-clause (iv) shall be valid for a period of one year and
subsequently, based on performance report, validity of recognition may be renewed for a further period of two years. (vi) The Chief Controller may revoke or suspend recognition granted to the operator, if the operator does not fulfill the obligations as mentioned in this Schedule. (vii) The Chief Controller may after giving an opportunity to the operator of being heard,
may revoke the recognition- (a) if he has reason to believe that the operator, has violated any condition stipulated in the letter of recognition or has acted in a manner inconsistent with the intent or the purpose of these rules; or (b) for any other reason to be recorded in writing.” 11.

ondition stipulated in the letter of recognition or has acted in a manner inconsistent with the intent or the purpose of these rules; or (b) for any other reason to be recorded in writing.” 11. In the said rules, for Schedule IV, the following Schedule shall be substituted, namely:-

“SCHEDULE IV [See rule 2 (va), 21 (15) and 29]

LNG Storage, Handling, Transportation, Operation, Maintenance and Dispensing These provisions shall apply to the following, namely:- (A) The requirements of the design, fabrication and installation and commissioning of LNG storage facility using cryogenic vacuum insulated containers of double wall constructed in accordance with approved pressure vessel codes and the requirements for safe vaporization, transfer and handling.
(B) The requirements of the road transportation of LNG in a cryogenic double walled vacuum insulated pressure vessel for the safe transportation and handling. (C) Operation, Maintenance and Training.
(D) LCNG stations or Auto LNG dispensing: Provided that the Chief Controller, may, under exceptional circumstances and for reasons recorded in writing, waive any of the requirements of this Schedule.
SECTION–I STORAGE INSTALLATIONS AND HANDLING A.

at the Chief Controller, may, under exceptional circumstances and for reasons recorded in writing, waive any of the requirements of this Schedule.
SECTION–I STORAGE INSTALLATIONS AND HANDLING A. INSTALLATION DESIGN: (1) (a) For LNG cryogenic pressure vessels storage installation, the minimum safety distances between the vessel and to the nearest building or line of adjoining property shall be in accordance with the distances specified in Table (1) of this Schedule and the maximum aggregate capacity of each such LNG installation shall not exceed 1060m3.

26
[PART II—SEC. 3(i)]

(b) For non-pressurised LNG storage installation, the minimum safety distances specified in NFPA 59A, may be followed. (2) The LNG installation shall be designed to withstand the following without loss of structural or functional integrity - (a) The direct effect of wind forces;
(b) Loading due to seismic effect; (c) Erosive action from a spill; (d) Effect of the temperature, any thermal gradient, and any other anticipated degradation resulting from sudden or localised contact with LNG. (3) The structural members of the impoundment system shall be designed and constructed to prevent impairment of the impoundments reliability and structural integrity as a result of the following- (a) Imposed loading from full hydrostatic head of impounded LNG; (b) Hydro dynamic action from injected material.

the impoundments reliability and structural integrity as a result of the following- (a) Imposed loading from full hydrostatic head of impounded LNG; (b) Hydro dynamic action from injected material. (4) Impoundment or dyke areas shall be designed so that all areas drain completely to prevent water collection and drainage pumps and piping may be provided to remove water from collecting in the impoundment area provided where automatically controlled drainage pumps are used they shall be provided with cut off devices that prevent their operation when exposed to LNG temperature. (5) Compressors, CNG Cascades, Odorizers etc. shall not be located inside the impounding area. (6) The Ambient vaporizers and remotely heated vaporizers may be located inside impounding area. (7) The impounding system for LNG storage vessel shall have a minimum volumetric liquid capacity of-
(a) maximum liquid capacity of vessel for an impoundment serving a single vessel; (b) 100% of maximum liquid capacity of the largest vessel serving for more than one vessel.
(8) The height of the impoundment wall shall be adequate to contain spillage of any LNG and the Dyke wall height of 0.6 meter to 1 meter is recommended from the dyke floor level and the height of the foundation of the vessel shall be minimum 0.4 meter or designed in such away to prevent exposure of carbon steel material to the spilled LNG.
(9) No other flammable liquid or storage vessel shall be located within an LNG impounding area.

0.4 meter or designed in such away to prevent exposure of carbon steel material to the spilled LNG.
(9) No other flammable liquid or storage vessel shall be located within an LNG impounding area. (10) A clear space of at least 0.9 meters shall be provided for access to all isolation valves serving multiple vessels and the isolation valve of LNG vessel piping shall be as close to outer vessel as possible. (11) LNG vessels, cold boxes, piping and pipe supports and other cryogenic apparatus installed within dyke shall be designed and constructed in a manner to prevent damage to these structures and equipment due to freezing or frost heaving in the soil. (12) Adequate flameproof lighting arrangement shall be done for facilities transferring LNG during night. (13) Electrical grounding and bonding shall be provided. (14) Layout shall ensure unobstructed access and exit of the consumers and supply vehicles at all times. (15) Entrance, exit and paving shall be arranged in a manner, so as to minimise the risk of collision. (16) The operating personnel shall have an unobstructed overall view on the facilities both from the sales room and from the delivery area. (17) The designated tanker unloading location shall be so located that it does not hinder other traffic and at the same time permits tanker to be in drive out position for allowing it to come out of the premises easily in case of an emergency. (18) Crash or Impact barriers shall be installed to protect vulnerable equipment against accidents involving vehicle movements.

ng it to come out of the premises easily in case of an emergency. (18) Crash or Impact barriers shall be installed to protect vulnerable equipment against accidents involving vehicle movements.

¹Hkkx IIµ[k.M 3(i)º 27 (19) The storage area which includes the pumps and the related piping shall be suitably segregated from the rest of the premises and located in a manner that it is away from the area frequented by public during their
movement within the station and also from the path of vehicles entering and leaving the premises.

TABLE-1 DISTANCES FROM IMPOUND WALL AND PROPERTY LINE Sl. No. Water Capacity of the vessel (m3) Minimum distance from edge of impoundment or vessel drainage system to property line Minimum distance between storage vessels

  1. Not above 3.8 3 m 0.5 m
  2. Above 3.8 but not above
    7.6 5.0 m 1 .0 m
  3. Above 7.6 but not above
    56.8 8.0 m 1.5 m
  4. Above 56.8 but not above 114.0 15.0 m 1.5 m
  5. Above 114.0 but not above 265.0 25.0 m 1/4 of the sum of the diameters of adjacent vessel (minimum 1.5 m)
  6. Above 265.0 but not above 379 vessel diameter (minimum 30.0 m) TABLE-2 MINIMUM DISTANCE BETWEEN VESSEL AND DYKE WALL Sl. No. water capacity of vessel (m3) Inner edge of the dyke wall and outer shell of the storage vessel or D/2 (whichever is higher)

Not above 3.8 0.5 m 2. Above 3.8 but not above 7.6 1.0 m 3. Above 7.6 but not above 56.8 1.5 m 4. Above 56.8 but not above 114.0 1.5 m 5.

storage vessel or D/2 (whichever is higher) 1. Not above 3.8 0.5 m 2. Above 3.8 but not above 7.6 1.0 m 3. Above 7.6 but not above 56.8 1.5 m 4. Above 56.8 but not above 114.0 1.5 m 5. Above 114.0 but not above 265.0 1/4 of the sum of the diameters of adjacent vessels (minimum 1.5 m) 6. Above 265.0 but not above 379

28
[PART II—SEC. 3(i)]

TABLE-3

MINIMUM DISTANCES BETWEEN EQUIPMENTS / ITEMS INSTALLED OUTSIDE THE DYKE WALL AND OUTER EDGE OF DYKE WALL

Sl. No. Equipment / Items Dyke wall (Outer Edge) 1. Property Line / Fencing As per Table 1 of this schedule 2. Center of Truck Unloading Platform
Min. 4.0 m (and also min 9 m from the adjoining boundary/property). The fill point shall observe 9.0 meter safety distance to the adjoining boundary. 3. Priority panel Outside dyke wall 4. CNG Cascade (For LCNG station) The safety distance as per Table I A of Gas Cylinders Rules, 2016 from edge of the dyke. The cascade shall be segregated from LNG facility by providing concrete wall up to the height of the cascade. 5. On site building/ Control room/sales office Outside the safety distances as per Table 1 of this schedule. 6. LNG and CNG dispensers (if LCNG station) Min. 6.0 m
(and also min 6.0 m from centre of hard stand).
7. Distance between Dispenser Islands Min.

istances as per Table 1 of this schedule. 6. LNG and CNG dispensers (if LCNG station) Min. 6.0 m
(and also min 6.0 m from centre of hard stand).
7. Distance between Dispenser Islands Min. 6.0 m
(and also min 6.0 m from

(B) LNG STORAGE VESSEL - General design requirements:
(a) Foundation : (1) LNG vessels foundations shall be designed by a qualified engineer and constructed in accordance with recognised structural engineering practices and prior to the start of design and construction of the foundation, a subsurface investigation shall be conducted by a qualified soils engineer to determine the stratigraphy and physical properties of the soils underlying the site. (2) The design of saddles and legs for the LNG vessel shall include erection load, wind loads and thermal loads. (3) Foundation and support shall have a fire resistance rating of not less than two hrs.
(4) LNG vessels installed in areas subject to flooding shall be secured to prevent release of LNG or floatation of the vessel in the event of a flood. (b) Vessel Design : (1) The vessel meant for storage of LNG including piping between inner and outer vessel shall be designed in accordance with ASME Boiler and Pressure Vessel Code Section VIII Div I / EN13458 / ASME: B.31.3, process piping or equivalent code acceptable to Chief Controller. (2) Design pressure of auto LNG storage vessel shall not exceed 20.0 Kg/cm².

ssel Code Section VIII Div I / EN13458 / ASME: B.31.3, process piping or equivalent code acceptable to Chief Controller. (2) Design pressure of auto LNG storage vessel shall not exceed 20.0 Kg/cm².
(3) The inner vessel shall be designed for the most critical combination of loading resulting from
internal pressure, liquid heads and the Inner vessel supports system shall be designed for shipping, seismic, and operating loads.

¹Hkkx IIµ[k.M 3(i)º 29 (4) The outer vessel shall be equipped with a relief or other device to release internal pressure and shall have discharge area of at least 0.34 mm2/lit of the water capacity of the inner vessel but not exceeding 2000 cm2 and have pressure setting not exceeding 25 psi. (5) Thermal barriers shall be provided to prevent outer tank from falling below its design temperature. (6) Those parts of LNG vessels which come in contact with LNG and all materials used in contact with LNG or cold LNG vapor shall be physically and chemically compatible with LNG and intended for service at – 162°C. (7) All piping that is a part of LNG vessel including all piping internal to the vessel, within void space, and external piping connected to the vessel up to the first circumferential external joint of the piping shall be in accordance with ASME Boiler and Pressure Vessel Code, Section VIII or ASME B 31.3 or equivalent. (8) LNG vessels shall be designed to accommodate both top and bottom filling unless other positive means are provided to prevent stratification.

sel Code, Section VIII or ASME B 31.3 or equivalent. (8) LNG vessels shall be designed to accommodate both top and bottom filling unless other positive means are provided to prevent stratification. (9) Any portion of the outer surface area of an LNG vessel that could accidentally be exposed to low temperatures resulting from the leakage of LNG or cold vapor from flanges, valves etc., shall be
intended for such temperatures or protected from the effects of such exposure. (10) Seismic loads shall be considered in the design of the LNG vessel support systems.

C. FITMENTS : (1) Each LNG double walled vessel shall have at least 2 numbers of safety relief valves capable of achieving the required relief capacity on standalone basis and shall be sized to relieve the flow capacity determined for the largest single contingency or any reasonable and probable combination of contingencies and shall include conditions resulting from operational upset, vapor displacement and flash vaporization. (2) Relief devices shall be vented directly to the atmosphere and each safety relief valve for LNG vessel shall be able to be isolated from the vessel for maintenance or other purposes by means of a manual full opening stop valve or a flow diverter valve. (3) Safety relief valve shall be designed and installed to prevent any accumulation of water, or other foreign matter at its end. (4) The minimum pressure relieving capacity in kg/hr shall not be less than 3% of the full tank contents in 24 hours.

lled to prevent any accumulation of water, or other foreign matter at its end. (4) The minimum pressure relieving capacity in kg/hr shall not be less than 3% of the full tank contents in 24 hours. (5) All liquid connections to the LNG vessel except relief valve and instrumentation connection shall be equipped with automatic fail safe product retention valves. (6) The automatic shut off valves shall be designed to close on occurrence of any of the following conditions, namely:-
(i) fire detection; (ii) uncontrolled flow of LNG from vessel; (iii) manually and remotely operated. (7) Such of the automatic shutoff valves that require excessive time to operate during emergency i.e. sizes exceeding 200mm shall be pneumatically operated and also have means of manual operation. (8) All LNG vessels shall have a device that prevents the vessel from becoming liquid full or from covering the inlet of the relief valve with liquid when the pressure in the vessel reaches the set pressure of relieving device under all conditions. (9) Every LNG vessel may be provided with one independent high liquid level alarm which may be part of the liquid level gauging devices, however, the high liquid level flow cutoff device shall not be considered as a substitute for the alarm.

e independent high liquid level alarm which may be part of the liquid level gauging devices, however, the high liquid level flow cutoff device shall not be considered as a substitute for the alarm. (10) Every LNG vessel shall be equipped with at least one liquid level gauging device and the devices shall be designed and installed so that they can be replaced without taking the tank out of operation and the level and pressure shall be visible to the operating personnel during unloading or loading and transfer. (11) Each LNG vessel shall be equipped with a high liquid level flow cut off device.
(12) Each LNG vessel shall be equipped with pressure gauge connected to the vessel at a point above the maximum intended liquid level.

30
[PART II—SEC. 3(i)]

(13)Instrumentation for storage and vaporization facilities shall be so designed so that if a power or instrument air failure occurs, the system will proceed to a failsafe condition and maintain that condition until the operator takes appropriate action to reactivate or secure the system.

D. EQUIPMENT : (1) Pumps and compressors employed in LNG source shall be provided with a pressure relieving device on the discharge to limit the pressure to the maximum safe working pressure of the casing and downstream piping and equipment. (2) Each pump shall be provided with adequate vent, relief valve, or both that will prevent over-pressuring the pump casing during the maximum possible rate of cool down.

eam piping and equipment. (2) Each pump shall be provided with adequate vent, relief valve, or both that will prevent over-pressuring the pump casing during the maximum possible rate of cool down. (3) The discharge valve of each vaporizer and the piping components and relief valves installed upstream of each vaporizer outlet valve/ spec break flange shall be designed for operation at LNG temperatures. (4) Two inlet valves shall be provided to isolate an idle, manifolded vaporizer to prevent leakage of LNG into the vaporizer and a safe means of disposing of the LNG or gas that can accumulate between the valves shall be provided in case the vaporizers are of size having inlets more than 50 mm diameter. (5) (i) The ambient air vaporizers shall be installed inside the containment area. (ii) Where the heated vaporizer is located 15 meter or more from the heat source, the remote shutoff location shall be at least 15 meter from the vaporizer. (iii) Where the heated vaporizer is located less than 15 meter from the heat source, it shall have an automatic shut off valve in the LNG liquid line located at least 3 meter from the vaporizer and shall close when either of the following occurs :

(1) Loss of line pressure (excess flow), (2) The occurrence of a fire is detected by an instrument designed for the purpose and located to detect a fire in the covered area, (3) Low temperature in the downstream of the vaporizer, (4) Manual ESD trip;

fire is detected by an instrument designed for the purpose and located to detect a fire in the covered area, (3) Low temperature in the downstream of the vaporizer, (4) Manual ESD trip; (iv) (a) Any ambient vaporizer or a heated vaporizer installed within 15 meter of an LNG vessel shall be equipped with an automatic shutoff valve in the LNG liquid line; (b) The automatic shutoff valve shall be located at least 3 meter from the ambient or heated vaporizer and shall close in either of the following situations, namely:- (1) Loss of line pressure (excess flow). (2) Abnormal temperature sensed in the immediate vicinity of the vaporizer (fire)
(3) Low temperature in the downstream of the vaporizer. (4) Activation of Emergency Shut Down System (ESD).

(c) If the facility is attended, manual operation of the automatic shutoff valve shall   be from a point at 

least 15 meter from the vaporizer, in addition to the requirement as specified in para (b) above. (v) The above conditions shall be applicable for LNG vaporizers for purposes other than pressure building coils or LNG to CNG (LCNG) systems.
(6) A distance of minimum 1 meter shall be maintained between vaporizers. (7) Vaporizers shall be designed, fabricated and inspected as per the requirements of ASME Boiler and Pressure Vessel Code, Section VIII Div. 1 or any other equivalent code acceptable to Chief Controller. (8) The material of construction of LNG vaporizers is recommended as Austenitic Stainless Steel piping with outer Aluminium fins.

Div. 1 or any other equivalent code acceptable to Chief Controller. (8) The material of construction of LNG vaporizers is recommended as Austenitic Stainless Steel piping with outer Aluminium fins.
(9) Manifold vaporizers shall be provided with both inlet and discharge block valves for each set of vaporizer. (10) Any ambient vaporizer installed within 15 meters of the LNG vessel shall be equipped with an automatic shutoff valve in the liquid line and this valve shall be located minimum at least 3 meters from the vaporizers and shall close when loss of line pressure occurs or abnormal temperature is sensed in the immediate

¹Hkkx IIµ[k.M 3(i)º 31 vicinity of the vaporizer or when low temperature in the vaporizer discharge line occurs. (11) Each set of vaporizer shall be provided with a safety relief valve(s) sized in accordance with the following requirements, namely:- (a) Ambient vaporizers–relief valve capacity shall allow discharge equal or greater than 150% of the rated vaporizer natural gas flow capacity without allowing the pressure to rise 10% above
the vaporizer maximum allowable working pressure. (b) Relief valves on heated vaporizers – same as sub-clause (a) above, however, it shall be located
such that they are not subjected to temperatures exceeding 60°C. during normal operation. (12) Automation shall be provided to prevent the discharge of either LNG or vaporizer gas into a distribution system at the temperature either above or below the design temperature of the send out system.

utomation shall be provided to prevent the discharge of either LNG or vaporizer gas into a distribution system at the temperature either above or below the design temperature of the send out system. (13) Vaporizers shall be provided with outlet temperature monitors.

E. PIPING SYSTEM : (1) All piping system and components shall be designed –
(a) To accommodate the effects of thermal cycling fatigue to which the systems shall be subjected.
(b) To provide for expansion and contraction of piping and piping joints due to temperature changes. (2) Piping material including gaskets and thread compounds shall be compatible throughout the range of temperature to which they are subjected. (3) The valves provided in the installation shall be of extended bonnet type with packing seals in a position that prevents leakage or malfunction due to freezing. (4) Shut-off valves shall be provided for all vessel connections except connections for liquid level alarms and connections that are blind flanged or plugged. (5) All the piping section between the two valves where the liquid may be trapped shall have the thermal relief valve. (6) Aluminium shall be used only downstream of a product retention valve in vaporizer service.

F. TRANSFER OF LNG : (1) Isolation valves shall be installed so that each transfer system can be isolated at its extremities and where power-operated isolation valves are installed, an analysis shall be made to determine the closure time so that it does not produce a hydraulic shock capable of causing line or equipment failure.

re power-operated isolation valves are installed, an analysis shall be made to determine the closure time so that it does not produce a hydraulic shock capable of causing line or equipment failure. (2) Adequate check valves shall be provided to prevent backflow and shall be located as close as practical to the point of connection to any system from which backflow might occur. G. PUMP AND COMPRESSOR CONTROL: In addition to a locally mounted device for shutdown of the pump or compressor drive, a readily accessible, remotely located device shall be provided at least 7.5 meters away from the equipment to shut down the pump in an emergency.

H. TANK VEHICLE UNLOADING FACILITIES: (1) The tank vehicle unloading area shall be of sufficient size to accommodate the vehicles without excessive movement or turning. (2) Transfer piping, pumps, and compressors shall be located or protected by barriers so that they are safe from damage by vehicle movements. (3) Isolation valves and bleed connections shall be provided at the unloading manifold for both liquid and vapour return lines so that hoses and arms can be blocked off, drained of liquid, and depressurized before disconnecting and bleeds or vents shall discharge in a safe area.

old for both liquid and vapour return lines so that hoses and arms can be blocked off, drained of liquid, and depressurized before disconnecting and bleeds or vents shall discharge in a safe area.

32
[PART II—SEC. 3(i)]

I. EMERGENCY SHUT DOWN SYSTEM (ESD System) :

(1) Each LNG facility shall incorporate an ESD system that when operated isolates or shuts off sources of LNG and shuts down equipment that add or sustain an emergency if continued to operate. (2) The ESD system shall be of a failsafe design and shall be installed, located, or protected from becoming inoperative during an emergency or failure at the normal control system. (3) Initiation of the ESD system shall be manual, automatic, or both manual and automatic. Manual actuators shall be located in an area accessible in an emergency and at least 15 meters away from the equipment they serve, and shall be distinctly marked with their designated function.

J. FIRE PROTECTION FACILITIES: (1) Each LNG storage facility shall be provided with flammable gas detectors, which shall activate visual and audible alarms at the plant site and at constantly attended location, if the facility is not attended continuously. (2) Flammable gas detection system shall activate an audible and a visual alarm at level not higher than 25% of the LEL of the gas being monitored.

n, if the facility is not attended continuously. (2) Flammable gas detection system shall activate an audible and a visual alarm at level not higher than 25% of the LEL of the gas being monitored. (3) Fire detectors shall activate an alarm at the plant site and at a constantly attended location if the plant site is not attended continuously and if determined by an evaluation that it is necessary then fire and gas detectors shall be permitted to activate the ESD system. (4) A fire water supply and delivery system shall be provided based on the risk analysis. However, as a minimum a fire water storage tank of 10 % of LNG storage tank capacity or 5000 liter whichever is higher with pumping facilities and hose reel system away from the LNG storage facility shall be provided for dispersion of LNG vapor cloud in case of leakage or spillage. (5) Portable or wheeled fire extinguishers of DCP and/or foam type shall be made available at strategic locations and at least 4 such extinguishers of 10 kg. capacity each shall be provided.
(6) Fire extinguishers provided in the LNG installations shall be based on high expansion foam and dry chemical powder.

K. PERSONAL PROTECTION: Every person operating the equipment in the LNG installation shall be equipped with the following personal protective equipment, namely:- (i) Suitable goggles for protection of eyes from LNG spray, (ii) Hand gloves suitable for cryogenic liquid handling, (iii) Protective apron, (iv) Safety Shoes.

al protective equipment, namely:- (i) Suitable goggles for protection of eyes from LNG spray, (ii) Hand gloves suitable for cryogenic liquid handling, (iii) Protective apron, (iv) Safety Shoes. SECTION 2
ROAD TRANSPORTATION

(A) DESIGN - GENERAL REQUIREMENTS : The safety relief valves provided on the inner vessel of the LNG transport tank shall be sized to meet most stringent condition of simultaneous occurrence of loss of vacuum and external fire and the combined capacity of the safety valves shall be sufficient to limit the pressure in the vessel to the test pressure - (1) The transport vessel shall be designed and constructed as per the ASME Boiler and Pressure Vessel Code Section VIII Div I pressure vessel code, EN13530 or equivalent code approved by Chief Controller and also to meet the requirements of ISO 20421 and the design temperature of the vessel, piping and valves shall be such that it is suitable for requirement sustaining cold shock caused by a loading of liquid Nitrogen into the vessel during its testing and commissioning.

f the vessel, piping and valves shall be such that it is suitable for requirement sustaining cold shock caused by a loading of liquid Nitrogen into the vessel during its testing and commissioning.

¹Hkkx IIµ[k.M 3(i)º 33 (2) Each vessel shall have adequate insulation that will prevent the vessel pressure from exciting the relief valve set pressure within the specified holding time when the vessel is loaded with LNG at the design condition of – (a) Specified temperature and pressure of the LNG, (b) The exposure of the vessel to the average ambient temperature of 40°C. (3) The outer vessel or jacket of the cryogenic vessel for transportation of LNG shall be made of no other material other than steel. (4) No Aluminium valve or fitting external to the wetted outer vessel shall be installed on LNG transportation vessels and each transportation vessel shall consist of a suitably supported welded inner vessel enclosed within an outer shell with vacuum insulation between the two. (B) STRUCTURAL INTEGRITY: (1) The design and construction of each vessel used for transportation of LNG shall be in accordance with ASME Boiler and Pressure Vessel Code Section VIII Div. 1, EN13530 or any other code approved by Chief Controller and the vessel design shall include calculation of stress due to design pressure, the weight of lading, the weight of structure supported by the vessel wall, and the effect of the temperature gradients resulting from lading and ambient temperature extremes.

e to design pressure, the weight of lading, the weight of structure supported by the vessel wall, and the effect of the temperature gradients resulting from lading and ambient temperature extremes. (2) In order to account for stresses due to impact in an accident, the design calculation of the vessel shell and heads shall include the load resulting from the design pressure in combination with the dynamic pressure resulting from a longitudinal deceleration of 2g. For this loading condition, the stress value used shall not exceed 75% of the yield strength of the material of construction. (3) The fittings and accessories mounted on the vessel shall be protected in such a way that damage caused by overturning can not impair operational integrity and this protection may take the form of cylindrical profile of the vessel, of strengthening rings, protective canopies or transverse or longitudinal members so shaped that effective protection is given. (4) The welding of the appurtenances to the vessel wall shall be made of attachment of the mounting pad so that there shall be no adverse effect upon the loading retention integrity of the vessel. (C) PRESSURE RELIEF DEVICES, PIPING, VALVES AND FITTINGS : (1) Hoses shall be suitable for the service and shall be designed for a bursting pressure of at least five times working pressure. (2) If a threaded pipe is used, the pipe and fitting shall be Schedule 80 or higher rating.

le for the service and shall be designed for a bursting pressure of at least five times working pressure. (2) If a threaded pipe is used, the pipe and fitting shall be Schedule 80 or higher rating. (3) Each hose coupling shall be designed for a pressure of at least 120% of the hose design pressure and there shall be no leakage when connected. (4) Piping shall be protected from damage due to thermal expansion and contraction, jarring and vibration and slip joints shall not be used. (5) Each valve shall be suitable for the vessel design pressure at the vessel design service temperature. (6) All fittings shall be rated for the maximum vessel pressure and suitable for the coldest temperature to which they will be subjected in actual service. (7) When a pressure building coil is used on the vessel, the vapor connection to that coil shall be provided with a valve or check valve as close to the vessel shell as practicable to stop flow in case of damage to the coil and the liquid connection to the coil shall also be provided with a valve. (8) Each vessel shall be rated for its holding time, the holding time being the time as determined by testing that will elapse from loading until the pressure of the contents, under equilibrium conditions reaches the level of the lowest pressure relief valve setting. (9) All the discharge lines of relief valves, vent valve, bleed valves etc., shall be connected to a vent stack which shall vent at a safe height. (10) Bursting discs shall not be used on the LNG transport vessels.

rge lines of relief valves, vent valve, bleed valves etc., shall be connected to a vent stack which shall vent at a safe height. (10) Bursting discs shall not be used on the LNG transport vessels.

34
[PART II—SEC. 3(i)]

(11) The outer vessel shall be protected by any accidental accumulation of pressure in the annular space by using a relief plate or plug or a bursting disc and the relief device shall function at a pressure not exceeding the internal design pressure of the outer tank, the external design pressure of the inner tank, or 25 psi whichever is less. (D) ACCIDENT DAMAGE PROTECTION : (1) All valves, fittings, pressure relief devices and other accessories to the vessels, which are not isolated from the vessel by closed intervening shut off valves or check valves shall be installed within the motor vehicle framework or within a suitable collision resistant guard or housing and appropriate ventilation, shall be provided and each pressure relief device shall be protected so that in the event of the upset of the vehicle on to a hard surface, the device’s opening will not be prevented and its discharge will not be restricted and the threaded end connection safety valves are preferred in stainless steel body construction.

a hard surface, the device’s opening will not be prevented and its discharge will not be restricted and the threaded end connection safety valves are preferred in stainless steel body construction. (2) Each protective device or housing and its attachment to the vehicle structure shall be designed to withstand static loading in any direction that it may be loaded as a result of front, rear, side or side wise collision or the overturn of the vehicle and all the valves of tank shall be at rear inside on operation box (cabinet) of suitable size and does not project out of tank diameter and the thickness of cabinet shall be minimum 3mm. (E) REAR END PROTECTION: (1) Rear end vessel protection devices shall consist of at least one rear bumper designed to protect the transport vessel and piping in the event of a rear end collision and the rear end vessel protection device shall be designed so that it transmits the force of the collision directly to the chassis of the vehicle. The rear end vessel protection device and its attachments to the chassis shall be designed to withstand a load equal to twice the weight of the loaded cargo vessel and attachments, using a safety factor of four based on the tensile strength of the materials used with such load being applied horizontally and parallel to the major axis of the transport vessel. (2) Every part of the loaded transport vessel and any associated valve, pipe, and enclosure or protected fitting or structure shall be at least 35.5 cm above ground level.

of the transport vessel. (2) Every part of the loaded transport vessel and any associated valve, pipe, and enclosure or protected fitting or structure shall be at least 35.5 cm above ground level. (F) DISCHARGE CONTROL DEVICES: (1) Each liquid filling and liquid discharge line shall be provided with a shut off valve located as close to the vessel as practicable and unless this valve is manually operable at the valve, the line shall also have a manual shut off valve. (2) Each liquid filling and liquid discharge line shall be provided with an on vehicle remotely controlled self- closing shutoff valve. (3) Each control valve shall be of fail-safe design and spring- based. (4) Each remotely controlled shut off valve shall be provided with on vehicle remote means of automatic closure, both mechanical and thermal. (5) Each remotely controlled shut off valve shall be provided with on-vehicle remote means automatic closure, both mechanical and thermal. One means may be used to close more than one remotely controlled valve and remote means of automatic closure shall be installed at the ends of the tanker farthest away from the loading or unloading connection area.

used to close more than one remotely controlled valve and remote means of automatic closure shall be installed at the ends of the tanker farthest away from the loading or unloading connection area. (G) SHEAR SECTION: Unless the valve is located in a rear cabinet forward of and protected by the bumper, the design and installation of each valve, damage to which could result in loss of liquid or vapor shall incorporate a shear section or breakage groove adjacent to and outboard of the valve and the shear section or breakage groove shall yield or break under strain without damage to the valve that would allow the loss of liquid or vapour. (H) SUPPORTS AND ANCHORING: In case, the transport tanker vehicle is designed and constructed in such manner that the vessel is not wholly supported by the vehicle frame, the transport vessel shall be supported by external cradles or load rings and the design calculations for the supports and load bearing vessel and the support attachments shall include

icle frame, the transport vessel shall be supported by external cradles or load rings and the design calculations for the supports and load bearing vessel and the support attachments shall include

¹Hkkx IIµ[k.M 3(i)º 35 beam stress, shear stress, torsion stress, bending moment and acceleration stress for the loaded vehicle as a unit, using a safety factor of four based on the tensile strength of the material and static loading that uses the weight of the transport vessel and its attachments when filled to the design weight of the loading. Minimum static loadings shall be maximum of the following individually, namely:- (i) Vertically downward of two (2);
(ii) Vertically upward of one and half (1.5);
(iii) Longitudinally of one and half (1.5); and (iv) Laterally of one and half (1.5).

(I) GAUGING DEVICES: (a) Liquid level gauging devices : The vessel shall have one liquid level device that provides a continuous level indication ranging from full to empty and that is maintainable or replaceable without taking the vessel out of service (b) Pressure gauges : Each vessel shall be equipped with a pressure gauge connected to the vessel at a point above the maximum liquid level that has a permanent mark indicating the maximum allowable working pressure of the tanker and the pressure gauge shall be housed in a canopy of the tanker.

SECTION 3 OPERATION, MAINTENANCE AND TRAINING

A. Each LNG installation shall provide for written operating, maintenance and training procedures.

uge shall be housed in a canopy of the tanker.

SECTION 3 OPERATION, MAINTENANCE AND TRAINING

A. Each LNG installation shall provide for written operating, maintenance and training procedures. Such procedures shall be drawn based on experience, knowledge of similar facilities.

B. Every installation shall meet the following requirements, namely:-

(1) Have written procedures covering operation, maintenance and training. (2) Keep up-to-date drawings of plant equipments. (3) Have written emergency plan as part of the operations manual. (4) Shall be in liaison with local authorities like Police, Fire Department, Health Authorities and keep them informed about emergency plans and their role in emergency situations. (5) Have documents wherein safety related malfunctions are identified and analyzed for the purpose of determining their causes and preventing the possibility of reoccurrence.

C. OPERATING PROCEDURES MANUAL : Every installation shall have a written manual of emergency procedures that shall include a types of emergencies that are anticipated and shall include the following procedures, namely:-

(1) Start up and shut down procedure including initial start up of the LNG facility. (2) Purging and inerting components.

are anticipated and shall include the following procedures, namely:-

(1) Start up and shut down procedure including initial start up of the LNG facility. (2) Purging and inerting components.

36
[PART II—SEC. 3(i)]

(3) Cooling down components. (4) Identify the possibility of abnormal conditions. (5) Safety precautions requirement to be taken while repairs or maintenance in the installation is being carried out. (6) Procedures for responding to controllable emergencies including notifying personnel and use of equipments i.e. appropriate to handling of emergency. (7) Procedure for recognising an uncontrollable emergency and for taking action to ensure that harm to the personnel in the premises and to the public outside is limited. (8) Procedure for immediate notification of the emergency to the local authorities. (9) Procedure for coordinating with local authorities in the preparation of any evacuation plan which may be required to protect the public in the event of emergency.

D. MAINTENANCE: (1) Every installation shall have a written procedure based on experience and knowledge of similar facilities and conditions under which the installation shall be maintained. (2) The procedure shall incorporate the need to carry out periodic inspection, tests on every equipment and system in service to verify that the equipment is maintained in accordance with the equipment manufacturer’s recommendations.

the need to carry out periodic inspection, tests on every equipment and system in service to verify that the equipment is maintained in accordance with the equipment manufacturer’s recommendations. (3) The written manual shall set out inspection and maintenance programme for each components forming part of the installation and in addition to fixing a schedule for inspection and tests, the procedure to be followed during repairs so as to ensure safety of persons and property shall also be laid down.

E. TRAINING : Every installation shall be provided with a training plan and the manner in which it will be implemented and maintained and the training manual shall comprise of under mentioned components- (1) Procedure of basic operation to be carried out in the installation in the normal course. (2) Carrying out of emergency procedures that relate to duties at the installation for each concerned personnel. (3) The characteristics and potential hazards of LNG during operation and maintenance of the facility, including dangers from frostbite that can result from contact with LNG. (4) The methods of carrying out duties of maintaining and operating the facility as set out in the manual of operating and maintenance procedures. (5) The LNG transfer procedure. (6) Fire prevention, including familiarization with the fire control plan of the installation, fire fighting, the potential causes of fire in a facility, and the types, sizes and likely consequences of a fire in the installation.

amiliarization with the fire control plan of the installation, fire fighting, the potential causes of fire in a facility, and the types, sizes and likely consequences of a fire in the installation. (7) Recognising situations in which it is necessary to obtain assistance in order to maintain the security of the facility.

¹Hkkx IIµ[k.M 3(i)º 37 SECTION 4 LNG OR LCNG DISPENSING This section lays down the requirements for Auto LNG dispensing station and LCNG facilities.

(A) GENERAL :
(1) LNG refueling sites dispensing saturated LNG with personnel in the immediate vicinity shall provide barrier walls or equal protection in order to protect the refuelling operator and vehicle. (2) All facility piping other than the refuelling hose to the vehicle shall be behind a barrier, which in the case of an equipment or device malfunction deflects the saturated LNG upward. (3) LNG dispenser shall observe minimum 6 m clear safety distance from the property line.

(B) SYSTEM COMPONENT QUALIFICATION: (1) Vehicle Fuelling Dispenser : (a) The type of the dispenser used for dispensing LNG shall conform to specification and be of a type approved by the Chief Controller. (b) The dispenser shall be protected from vehicle collision damage.
(c) An ESD shall be provided that includes a shutoff valve for stopping liquid supply and shutting down transfer equipment. (d) An ESD actuator, distinctly marked for easy recognition with a permanently affixed, legible sign, shall be provided near the dispenser, vehicle unloading facility and in sales/control room.

nt. (d) An ESD actuator, distinctly marked for easy recognition with a permanently affixed, legible sign, shall be provided near the dispenser, vehicle unloading facility and in sales/control room.
(e) The maximum delivery pressure at the fuelling nozzle shall not exceed the maximum allowable working pressure of the vehicle fuel tanks. (f) (i) Hose or arms shall be equipped with a shutoff valve at the fuel end and a breakaway device to minimise release of liquid and vapour in the event that a vehicle pulls away while the hose remain connected. (ii) Such a device shall be installed and maintained in accordance with the OEM component manufacturer’s maintenance/safety instructions. (iii) A breakaway device shall be arranged to separate using a force not less than 102 kgf and not greater than 125 kgf where applied in any direction that the vehicle would move. (g) The hose shall be secured to protect it from damage when not in use. (h) (i) Where a hose or arm of nominal 76 mm diameter or larger is used for liquid transfer or where one of nominal 100 mm diameter or larger is used for vapour transfer, an emergency shutoff valve shall be installed in the piping of the transfer system within 3.1 meter from the nearest end of the hose or arm. (ii) Where the flow is away from the hose, a check valve shall be permitted to be used as the shutoff valve. (iii) Where either a liquid or vapour line has two or more legs, an emergency shutoff valve shall be installed either in each leg or in the feed line before the legs.

used as the shutoff valve. (iii) Where either a liquid or vapour line has two or more legs, an emergency shutoff valve shall be installed either in each leg or in the feed line before the legs. (i) The OEM manufacturer’s instructions shall be posted near the dispenser. (j) Operating instructions identifying the location and operation of emergency controls shall be posted conspicuously in the facility area. (k) LNG fuelling facilities transferring LNG during the night shall have permanent, adequate lighting at points of transfer and operation.

38
[PART II—SEC. 3(i)]

(l) The transfer of LNG into vehicular onboard LNG containers shall be performed in accordance with the onboard LNG container and refuelling component OEM manufacturer’s instructions.

(2) Vehicle Fuelling Connector: (a) A fuelling connector and mating vehicle receptacle shall be used for reliable, safe, and secure transfer of LNG or gas vapour to or from the vehicle. (b) The fuelling connector either shall be equipped with an interlock device that prevents release while the line is open or have self-closing ends that automatically close upon disconnection. (3) Installation of Emergency Shutdown Equipment (ESD): (a) ESD shall be provided near to the dispenser, LNG unloading facilities and sales or control room. (b) Instrumentation for LNG fuelling facilities shall be designed so that, in the event of a power or instrumentation failure, the system goes into a fail-safe condition until the operators either reactivate or shut down the system.

g facilities shall be designed so that, in the event of a power or instrumentation failure, the system goes into a fail-safe condition until the operators either reactivate or shut down the system. (c) All ESDs shall be manually reset.

                                               SECTION 5 

NON FUELING FACILITIES IN LNG OR LCNG STATIONS

Non fuelling facilities like small convenience stores, service station, ATM, PCO, whenever provided, shall be beyond safety distance mentioned in this schedule. In addition a minimum distance of 10 meter from the LNG/LCNG dispensers shall be maintained and the accessibility to such non fuelling facilities shall not be through operational area. While providing such facilities, factors like degree of congestion in the premises, easy entry and exit of the vehicle coming for refuelling and easy manoeuvrability of LNG road tanker while moving out of the premises in the event of emergency shall also be taken into consideration.

SECTION 6 BOIL OFF GAS MANAGEMENT

When LNG station is being set up, the capacity of storage tank may be optimized so as to minimize the BOG venting. For effective BOG management, the operator may use the gas to avoid venting with the approval of the Chief Controller.

SECTION 7 RECOGNITION OF AUTO LNG INSTALLER

A. The company intending to install LCNG/Auto LNG dispensing station shall meet the following criteria for considering recognition by the Chief Controller.

N 7 RECOGNITION OF AUTO LNG INSTALLER

A. The company intending to install LCNG/Auto LNG dispensing station shall meet the following criteria for considering recognition by the Chief Controller. It shall -

(i) be proprietary firm or partnership firm or private limited company or limited company; (ii) possess adequate tools and machinery to execute installation work;

¹Hkkx IIµ[k.M 3(i)º 39 (iii) possess ISO certification;

(iv) Have sufficient in-house specialists well conversant with- (a) Installation of LCNG or Auto LNG equipments, their operations, maintenance and training of personnel; (b) LCNG or Auto LNG regulations and the hazards associated; (c) Codes of practice relating to setting up LCNG or Auto LNG stations; (d) interpretation of drawing and schemes as far as relevant for the execution of the work; (v) strength of the personnel engaged by the firm or company shall be in agreement with the number of stations proposed to be installed or maintained; (vi) have professional administration and organisation with clear levels of responsibility; (vii) take responsibility for the development of professional skills of its personnel; (viii) take responsibility of operations, periodic maintenance and breakdown maintenance in the stations and enters into a legal agreement with its dealers in this respect for specific period;

B.

(viii) take responsibility of operations, periodic maintenance and breakdown maintenance in the stations and enters into a legal agreement with its dealers in this respect for specific period;

B. Procedure for granting recognition of LCNG or Auto LNG installer:

(i) Any organisation intending to be recognised as LCNG or Auto LNG dispensing station installer shall submit application giving details of their company’s credentials with regard to their experience in the field of installation and maintenance of LCNG or Auto LNG dispensing station to the Chief Controller.
(ii) Every application shall be accompanied by a scrutiny fee as specified in Part B of Schedule I.
(iii) The Chief Controller shall within a period of ninety days from the date of receipt of the application either–
(a) prima facie after having satisfied himself with regard to competence and professional ethics, for recognition of the applicant as a LCNG/Auto LNG dispensing station installer, as the case may be, shall call the applicant along with his technical team for an interview by a team of officers nominated by Chief Controller for assessing the technical and practical knowledge and capability of the applicant; or
(b) if the applicant does not prima facie meet the requirement for recognition shall reject the application with reasons; or (iv) (a) if the applicant in the interview conducted under this rule is found to have adequate knowledge and capability for the recognition applied for, the Chief Controller shall grant the recognition under the rules.

icant in the interview conducted under this rule is found to have adequate knowledge and capability for the recognition applied for, the Chief Controller shall grant the recognition under the rules. (b) in case any applicant is not found suitable, the Chief Controller shall reject the application specifying the reasons.
(v) initially the recognition granted under clause (iv) shall be valid for a period of one year and subsequently, based on performance report, validity of recognition may be renewed for a further period of two years. (vi) Chief Controller may revoke or suspend recognition granted to the installer if the installer does not full-fill the obligations as mentioned in this Schedule. (vii) the Chief Controller may after giving an opportunity to the installer of being heard, may revoke the recognition- (a) if he has reason to believe that the installer, has violated any condition stipulated in the letter of recognition or has acted in a manner inconsistent with the intent or the purpose of these rules; or (b) for any other reason to be recorded in writing.

ed any condition stipulated in the letter of recognition or has acted in a manner inconsistent with the intent or the purpose of these rules; or (b) for any other reason to be recorded in writing.

40
[PART II—SEC. 3(i)]

SECTION 8 EMERGENCY PLAN

Every LCNG or Auto LNG dispensing station shall have a written emergency plan in place to control the hazards from serious auto LNG leakage or fire and this plan shall contains instructions for emergency shutdown of the station, warning to customers and other people in the surrounding, calls for assistance, usage of fire fighting equipments among others and the plan shall be tested from time to time for evaluation of its adequacy and shall be updated and modified as required”.

In the said rules, after “Form LS-1B”, the following Form shall be inserted, namely:- “FORM LS-1C (See rules 50, 51, 54 and 55) LICENCE TO STORE AND DISPENSE AUTO LNG IN AUTO LNG DISPENSING STATION AS AUTOMOTIVE FUEL TO MOTOR VEHICLES.

Licence No :_____________________

Fee Rs. ________________

Licence is hereby granted to ____________________________________________ for storage of auto-LNG in the cryogenic pressure vessels indicated below in the premises described below and dispensing of auto-LNG/ LCNG as automotive fuel to motor vehicles, subject to the provisions of the Indian Explosive Act, 1884 (4 of 1884) and the rules made there under and to the further conditions of this licence.

The licence shall remain in force up to the 30th day of September 20____________.

ve Act, 1884 (4 of 1884) and the rules made there under and to the further conditions of this licence.

The licence shall remain in force up to the 30th day of September 20____________.

The _____________20 Chief Controller of Explosives /Controller of Explosives
DESCRIPTION OF LOCATION AND FACILITIES OF THE LICENSED PREMISES

The licenced premises, the layout, boundaries and other particulars of which are shown in the attached approved plan No. ________________dated _____________are situated at (address)_________________________________________________________and consists( in addition to storage vessels mentioned above) of :-

(i)numbers dispensers, make (ii) other facilities_____________________

SPACE FOR ENDORSEMENT OF RENEWALS

The licence shall be renewable without any concession in fee for five years in the absence of contravention of the provisions of the Indian Explosives Act, 1884 or Static and Mobile Pressure Vessels (Unfired) Rules, 2016 framed there under, or of the condition of the licence. Date of Renewal Date of Expiry Signature and Office Stamp of the Licensing Authority

This licence is liable to be cancelled if the licensed premises are not found conforming to the description and conditions attached hereto and for contravention of any of the rules and conditions of this licence and the holder of this licence is also punishable under the Act.
Vessel No. Water capacity in cubic meter Quantity of auto-LNG granted in Kgs

any of the rules and conditions of this licence and the holder of this licence is also punishable under the Act.
Vessel No. Water capacity in cubic meter Quantity of auto-LNG granted in Kgs

¹Hkkx IIµ[k.M 3(i)º 41 CONDITIONS

  1. The licensed premises shall conform to the description of location and facilities and to the approved plan, as mentioned on the body of the licence.
  2. The licensed premises shall be used only for the purpose it is licensed for.
  3. Every licensed premises under these rules shall have prominently marked thereon the number of the licence held for it.
  4. The emergency telephone numbers of local fire service, police and the principal marketing company or supplier of the compressed gas, and emergency instructions shall be conspicuously displayed in the licensed premises.
  5. Auto-LNG shall be stored only in one or more pressure vessels installed aboveground, as per provisions of these rules.
  6. The storage vessel, pumps, dispenser, piping and other fittings shall be of a design suitable for auto-LNG.
  7. Storage vessels shall not be installed within any building or shed.
  8. A hard stand for parking the tank-truck for the purpose of unloading auto-LNG into the storage vessels shall be provided as per rules.
  9. The facilities and equipments of the licensed premises shall meet the safety distance requirements as specified in Schedule IV.

LNG into the storage vessels shall be provided as per rules. 9. The facilities and equipments of the licensed premises shall meet the safety distance requirements as specified in Schedule IV. 10. Auto-LNG shall be dispensed only into those containers of motor vehicles, which are approved by the Chief Controller, and have passed the periodic statutory tests under Gas Cylinders Rules, conducted by a testing station recognised by the Chief Controller. 11. The dispenser used for dispensing auto-LNG shall conform to Schedule-IV and a specification approved by the Chief Controller. 12. All piping and fittings shall conform to Schedule-IV. 13. No person shall enter or cause to repair or repair either by the use of fire, welding, hot riveting or brazing any vessel used for the storage of flammable gas unless it has been thoroughly cleaned and gas-freed or otherwise prepared for safely carrying out such hot work and certified in writing, by a competent person. 14. The operation of the licensed premises shall be under the supervision of a person having knowledge of the equipments used in the premises and trained in handling compressed gas, and other operators shall be conversant with the hazards associated with the LNG, compressed gas and fire fighting operations. 15. Auto-LNG shall not be filled into or removed from the vessel except by means of transfer facilities shown in the approved plan attached to the licence. 16.

ed gas and fire fighting operations. 15. Auto-LNG shall not be filled into or removed from the vessel except by means of transfer facilities shown in the approved plan attached to the licence. 16. Smoking, naked lights, lamps, source of fire or any other stimulant capable of igniting flammable vapours shall not be allowed inside the premises and every person managing or employed on or in connection with licensed premises shall abstain from any act whatsoever which tends to cause fire or explosion and which is not reasonably necessary and to the best of his ability, shall prevent any other person from doing such act. 17. The vessel shall not be filled between the hours of sunset and sunrise without written permission from the chief controller. 18. All electrically equipment such as motors switches, starters, etc, used for transfer of LNG shall be of flameproof construction conforming to IS/IEC 60079-1 to 11 or of a type approved by Chief Controller. 19. At least two numbers of nine kilograms capacity dry chemical type fire-extinguishers shall be provided near the tank-truck unloading area and one number similar extinguisher shall be provided near each dispenser and transfer pump location. In addition, fire fighting facilities specified in Schedule IV shall be provided. 20. During the period of unloading of LNG from tank-truck to the storage vessels dispensing operation to the vehicles shall not be carried out. 21.

ties specified in Schedule IV shall be provided. 20. During the period of unloading of LNG from tank-truck to the storage vessels dispensing operation to the vehicles shall not be carried out. 21. The emergency telephone numbers of local fire service, police and the principal marketing company, and emergency instructions shall be conspicuously displayed in the licensed premises. 22. All valves on the vessel and pipelines in the premises shall be permanently marked in a manner clearly indicating the direction of opening and closing. 23. Free access to the licensed premises shall be given at all reasonable times to any of the officers specified in rule 70 and every facility shall be afforded to such officer for ascertaining that the rules and the conditions of this licence are duly observed.

42
[PART II—SEC. 3(i)]

  1. If the licensing authority calls upon the holder of a licence by a notice in writing to execute any repairs in the licensed premises which are, in the opinion of such authority, necessary for the safety of the premises, the holder of the licence shall execute the repairs within such period as may be specified in the notice.
  2. Any accident, fire, explosion or untoward incident occurred within the licensed premises shall be immediately reported to the Chief Controller, Controller, nearest police station and District Magistrate by quickest mode of communication.”.

[F. No. 2(1)2017-Expls] SHAILENDRA SINGH, Add.l Secy.

diately reported to the Chief Controller, Controller, nearest police station and District Magistrate by quickest mode of communication.”.

[F. No. 2(1)2017-Expls] SHAILENDRA SINGH, Add.l Secy.

Note:– The principal rules were published in the Gazette of India, Extraordinary, Part-II, Section 3,
Sub-section (i) vide notification number G.S.R. 1109(E), dated the 1st December, 2016.

Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054. RAKESH SUKUL Digitally signed by RAKESH SUKUL Date: 2018.05.01 18:57:32 +05'30'