SUB : Forwarding of samples for testing to the Outside Laboratories
Forwarding of samples for testing to the Outside Laboratories- reg.
OFFICE OF COMMISSIONER OF CUSTOMS NS-III JAWAHAR LAL NEHRU CUSTOM HOUSE, NHAVA SHEVA TAL: URAN, DIST. RAIGAD, MAHARASHTRA-400707
F.No.S/12-Gen-402/2017-18 AM(I) Pt I Date: 18.12.2017
PUBLIC NOTICE NO. 159/2017 SUB : Forwarding of samples for testing to the Outside Laboratories- reg.
Attention of the Importers, Exporters, General Trade, Custom Brokers and all other stakeholders in the jurisdiction of JNCH, Nhava Sheva is invited to the Board Circular No. 43/2017 dated 16th November, 2017 on the above mentioned subject.
It has been noticed that due to lack of testing facilities of certain goods in Revenue Laboratories, there is delay in clearance of the consignments of these goods due to avoidable movement of samples between Customs field formations and Revenue Laboratories.
-
In this regard, CRCL has shortlisted the items whose samples cannot be
tested in their Laboratories at present and also identified the Laboratories functioning under the other Ministries/Departments/Organizations where such samples could be tested. The list of such items and corresponding testing Laboratories are annexed herewith.
The Revenue Laboratories are, presently, in the process of up-gradation. However, until Revenue Laboratories are upgraded, as a measure of trade facilitation, the Board has decided that field formations may directly forward samples of goods mentioned in column (3) of the Annexure-1 of the Board Circular No. 43/2017 dated 16.11.2017, to the laboratories mentioned in column (4) of the said Annexure.
The procedure for forwarding the samples to the laboratories shall be as follows:
a. JNCH follows the respective standard sampling technique as prescribed by the concerned laboratory for the items under question. For any new items / goods, officers have been directed to ascertain sampling requirement with the laboratory concerned before drawing samples from the consignment. The sampling requirements has been specified in column no 5 of enclosed Annexure.
b. In cases of live consignments which cannot be cleared without getting the test reports due to its hazardous nature or for any other reason, the samples will continue to be forwarded to the concerned laboratory at the earliest.
Further, the all the Groups / Docks have been asked to develop a mechanism so as to get the test report expeditiously online.
c. In cases where the time taken by laboratory exceeds three days, the importer can warehouse the goods under section 49 of the Customs Act.
d. Testing fee, if any, shall be paid by the importer or the exporter.
It is further clarified that aforementioned procedure shall not be applicable in cases where Partner Government Agencies themselves draw the sample.
Action to be taken in terms of decisions taken in this Public Notice should be considered as standing order for the purpose of officers and staff. 8. Difficulty, if any may also be brought to the notice of Deputy / Assistant Commissioner in charge of Appraising Main (Import) through email / phones (email address: appraisingmain.jnch@gov.in , Phone No : 022-27244979,).
Sd/-
(SUBHASH AGRAWAL)
COMMISSIONER OF CUSTOMS
NS-III, JNCH
Copy (by email )to :
- The Chief Commissioner of Customs, Mumbai Zone- II.
- All the Commissioner of Customs, Mumbai Zone- II.
- All Addl./Joint Commissioners of Customs, Mumbai Zone- II.
- All Deputy/Asstt. Commissioners of Customs, Mumbai Zone- II.
- The DC/EDI for uploading on the JNCH website.
- BCBA / FIEO / AIIEO / Other Associations.
ANNEXURE-1 Sl.No. CTH Goods Lab Sampling procedure 1 1-8
- Dried and Freeze Dried Shrimps (Ch. 3) Central Inland Fisheries Institute (Under Ministry of Agriculture) ICAR
CIFRI, Monirampur (Post), Barrackpore, Kolkata, West Bengal – 700120.
Central Marine Fisheries Institute, Kochi, Karwar (Karnataka) (Under Ministry of Agriculture) Central Marine Fisheries Research Institute, Post Box No. 1603, Ernakulam North P.O., Kochi 682018. Phone: +91 484 2394357 /12, 2391407, 2394867, 2397569, 2394268 /96, 2394750, Fax: +91 484 2394909, E- mail:contact@cmfri.org.in. IS.11427.2001.pdf In drawing, preparing, storing and handling test samples, the following precautions and directions shall be observed. Samples shall be taken in a protected and clean place. The samples, the material being sampled, the sampling instrument(s) and containers for samples shall be protected from adventitious contamination. The sampling instrument(s) shall be of suitable size, capacity and clean and dry. Only sterilized sampling instruments shall be used for taking the samples to be tested for microbiological requirements. All sampling instruments shall preferably be made of glass or stainless steel. Samples shall be placed in clean and dry glass/stainless steel containers. These containers, wherever applicable, shall also be sterilized whenever samples are drawn for testing microbiological requirements. The sample containers shall be of such size that they are almost filled by the sample. Samples in containers shall be stored and transported in such a manner that there is no deterioration of the material. For frozen fish, temperature of storage transportation shall be –20”C. If samples are not immediately analysed, these shall be stored and transported without any direct contact with ice. In the case of canned produce the sample cans shall be stored and transported to the laboratory without any appreciable difference in the temperature. Samples shall be sent to the laboratory for testing as early as possible. Each sample container, after filling shall be sealed air-tight with a stopper or a suitable closure in such a way that it cannot be opened and resealed without detection. It shall be marked with fill details of sampling, such as date and place of sampling, name of the vendor and other import dt particulars of the consignment. 2 9 2. Nutmeg
Quality Evaluation Laboratory, Cochin (Under Ministry of Commerce & Industry) Spices Board, Ministry of Commerce & Industry, Govt. of India, Sugandha Bhavan, N.H. By Pass, Palarivattom. P.O Cochin 682025, Kerala India Email: sbqel@indianspices.com.
GENERAL_GUIDELINES_ON_SAMPLING.pdf
Samples to be taken, as far as possible, using sterile techniques i.e., sampling personnel should
use sterile gloves, sealed sterilised bags or sterile bottles. To avoid contamination from lot to lot, the
sampling equipment has to be clean, dry and free from foreign odours. Samples to be taken for microbial
analysis should be collected in sterile containers. Whenever possible, submit samples to the laboratory
in the original unopened containers.
Use containers that are clean, dry, leak-proof, wide-mouthed, sterile, and of a size suitable for
samples of the product. Containers such as plastic jars or metal cans that are leak-proof may be
hermetically sealed. Whenever possible, avoid glass containers, which may break and contaminate the
food product. Do not use a felt pen on plastic because the ink might penetrate the container. Whenever
possible, obtain at least 100 g for each sample unit. Deliver samples to the laboratory promptly with the
original storage conditions maintained as nearly as possible. Dry or canned foods that are not perishable
and are collected at ambient temperatures need not be refrigerated.
Samples should be despatched to the Public Analyst as soon as practically possible to avoid any
discrepancies in testing.
Quantity of sample to be drawn which will be sufficient for the required analysis as per the
FSSA i.e. 150g.
3. Saffron
Spices Board, Mata Naina Devi Marg, Near Haldiram
Restaurant, Block J, Lajpat Nagar III, New Delhi, Delhi
110024 Phone: 011 29845040
IS.13145.1993 spices.pdf
From each of the containers selected from the lot, equal number of increments (small quantity)
shall be taken and thoroughly mixed so as to form the gross sample. The increments, from each of the
containers sampled from the lot, shall be taken from different sides and depths (top, middle and bottom)
so as to obtain representative quantity of material.
If required, the containers selected from the lot shall be completely emptied and content mixed
before taking increments.
If the containers are packed in case, 5 percent of the cases subject to minimum of 2 shall be
selected and approximately equal number of containers selected from each so as to constitute the
requisite sample size.
The quantity of material obtained in the gross sample shall be suitably reduced by the
procedure of coning and quartering so as to obtain the laboratory sample.
For coning and quartering, the material shall be heaped into the shape of a cone by pouring
scoopful of the material one after another at the apex of the cone till entire gross sample has been coned.
The material shall be allowed to slide down the sides of the cone only under the influence of gravity.
The cone shall be evenly flattened so that it forms a low circular pile. The pile shall be cut into four
quarters along two diameters which intersect at right angles, one pair of opposite quarters shall be
retained and the other one rejected. The procedure shall be repeated till the laboratory sample of
requisite size is obtained.
The quantity of material in the gross sample and laboratory sample shall be 100g and 15g
respectively
3
13
4. Gum Karaya
Indian Institute of Natural Resins & Gums, Ranchi (Under Ministry of Agriculture) ICAR- IINRG (Formerly Indian Lac Research Institute), Namkum, Ranchi - 834010. Ph: 2260117, 2261156, Fax: 226020
Sampling to be done as per guidelines issued by JNCH vide S.O. No. 17/2009 JNCH, dated 21.04.2009.
- Saphora Japonica Extract Central Institute of Medicinal & Aromatic Plants (CIMAP), Lucknow, (Under Ministry of Agriculture) CSIR- CIMAP, PO CIMAP, Near Kukrail Picnic Spot, Lucknow, Uttar Pradesh 226015 Phone: 0522 271 9083,Website: www.cimap.res.in 4 15
- Refine Rape Seed Low Euric Acid Canola Oil
Central Food Technology Research Institute (CFTRI), Mysore, CSIR-CFTRI, Cheluvamba, Mansion Opp. Railway Museum, Mysuru, Karnataka 570020
Volume_IV_Ensuring_FSS_Food_Sampling_Analysis (1).pdf
-
Oils in Bulk in Storage Tanks and Tank Wagons: IS.548.1.1964.pdf:-
Stationary - Lower the closed sampling bottle or can slowly to the required depth, open and fill it at that depth. Three samples shall be obtained at levels of one-tenth of the depth of the liquid from the top surface (top sample), one-half of the depth (middle sample) and nine-tenths of the depth of the liquid from the top surface (lower sample). If foots (sediment) or water or both are present, a bottom sample shall also be taken at the lowest point of the container (bottom sample). All the samples shall be mixed together in a clean dry container, and shall be reduced. During loading or unloading - If the product is completely liquid and free flowing, the pet-cock method of sampling may be used. A bleeder line with a pet-cock ( 10 mm minimum inside diameter) is located in a vertical section of the pumping line through which the product is continuously flowing. Adjust the pet-cock so that a continuous stream of sample flows freely without dripping during the entire pumping period. Collect the sample in a clean dry container and protect it from dirt, water or other contamination. Mix the entire sample thoroughly and reduce it.
In the event of a pet-cock not being available, use a convenient container and withdraw approximately 0.5 kg portions from the discharge end of the pipe at regular intervals as the product is entering or leaving the tank wagon. -
Oils in Barrels, Casks, Drums and Tierces:- Liquid or semi-solid oils - Roll the container to mix the contents and insert the sampling tube slowly through the bung hole or any other convenient opening. If possible, the sample should be drawn from end to end. As soon as the tube is fully inserted, close the upper constriction with the thumb or a stopper, withdraw the tube and transfer the sample into a clean dry container. Take several portions in this manner from this and other packages. Mix thoroughly. The sample containers should be almost but not completely filled. The sample containers shall be sealed with sealing wax in such a manner that it is not possible to remove the contents and the label without breaking the imprint of the seal. The minimum size for each test sample shall be 0.5 kg. Rubber stopper should not be used to close the containers. In case of glass containers, glass stoppers or new good quality velvet corks should be use and, in the case of tine containers, tin caps should be suitably soldered on the top, avoiding contamination of fat with acid flux. Use of resin as a flux is recommended. Tinfoil or greaseproof paper may be wrapped round the corks to prevent contact of sample with them, and it is recommended that this be done in the case of refined or deodorized edible oils. In case of oils with high acid value, neither metal containers nor tinfoil is recommended.
-
Pure Ghee
FSSAI Approved Laboratories (Under Ministry of Health & Family Welfare) FDA Bhavan, Near Bal Bhavan, Kotla Road, New Delhi 110002
Volume_IV_Ensuring_FSS_Food_Sampling_Analysis.pdf (a) Sampling shall be carried out in such a manner as to protect the sample, the sampling instruments and the containers in which the samples are placed from adventitious contamination, such as rain and dust. (b) Material adhering to the outside of the sampling instruments shall be removed before the contents are discharged. (c) A sample shall be drawn from each container to be sampled with the sampling instrument which is inserted through a convenient opening in such a manner as to sample the entire depth of the contents. (d) All samples from the same consignment shall be put into a clean and dry receptacle, preferably of stainless steel. The contents of the receptacle shall be thoroughly mixed and the required sample drawn into a clean and dry sample container. (e) The sample container shall be closed, leaving sufficient air space at the top for expansion. On the other hand this space shall not be too large, as air exerts detrimental action. (f) All samples shall be protected from light and heat, and kept in a cool place. 5. 17 8. Molasses Central Food Technology Research Institute (CFTRI), Mysore, (Under Ministry of Science and Technology) CSIR-CFTRI, Cheluvamba, Mansion Opp. Railway Museum, Mysuru, Karnataka 570020.
FSSAI Approved Laboratories (Under Ministry of Health
& Family Welfare Ministry of Health & Family Welfare,
FDA Bhavan, Near Bal Bhavan, Kotla Road, New Delhi
110002
IS.1162.1958 molasses.pdf
In drawing, preparing, storing and handling test samples, the following precautions and
directions shall be observed.
The sampling instrument shall be clean and dry when used.
The samples, the material being sampled, the sampling instrument and the containers for
samples shall be protected from adventitious contamination.
To draw a representative sample, the contents of each container selected for sampling shall be
mixed as thoroughly as possible by shaking or stirring or both, or by rolling so as to bring all portions
into uniform distribution.
The samples shall be placed in suitable, clean, dry and air-tight metal of glass containers, on
which the material has no action.
The sample containers shall be of such a size that they are almost, but not completely, filled by
the sample.
Each sample container shall be sealed air-tight with a glass stopper after filling, and marked
with full details of the sample and the date of sampling.
1.
Sampling from Tank/Tanker - Take equal portions of the material from different layers of the
tank/tanker with the help of the sampling can to obtain a quantity not less than 2·5 liters and mix
thoroughly in a suitable container which is dry and clean, to obtain a composite sample for the
tank/tanker. Divide this composite sample in three equal portions of nut less than 750 ml in dried bottles
or other containers, seal air-tight and label with all the particulars of sampling.
2.
Sampling from Containers :-
Mixing - Thoroughly mix the contents of all the container in the gross sample whether they are drums or
cans of others, by shaking or stirring, or both, or by rolling so as to bring all portions into uniform
distribution.
Drawing of Samples - Draw by inserting the sampling device through the bung hole or any other
convenient opening, equal portions of the well-mixed material from each container in the gross sample so as to obtain a quantity not less than 2.5 litres. Divide this composite sample into three equal portions of not less than 750 ml in dried bottles or other containers, , seal air-tight and label with all the particulars of sampling. 6 21 9. Pan Masala Central Food Technology Research Institute (CFTRI), Mysore, (Under Ministry of Science and Technology) CSIR-CFTRI, Cheluvamba, Mansion Opp. Railway Museum, Mysuru, Karnataka 570020
FSSAI Approved Laboratories (Under Ministry of Health & Family Welfare Ministry of Health & Family Welfare, FDA Bhavan, Near Bal Bhavan, Kotla Road, New Delhi 110002 Similar to procedure as provided for sampling of “pure ghee” (Sl. No. 7.) 7 23 10. Steam Dried Fish Meal
- Fish Protein Central Institute of Fisheries Technology (CIFT), Kochi (Under Ministry of Agriculture) ICAR-CIFT Junction, Willingdon Island, Matsyapuri P.O., Cochin-682 029, Kerala Ph: 0484-2412300
Central Marine Fisheries Institute, Kochi, Karwar (Karnataka) (Under Ministry of Agriculture) Central Marine Fisheries Research Institute, Post Box No.1603, Ernakulam North P.O., Kochi 682018
Central Inland Fisheries Institute, Barrackpore, Kolkata, (Under Ministry of Agriculture) ICAR
- CIFRI, Monirampur (Post), Barrackpore, Kolkata, West Bengal -
IS.4307.1983 fish meal.pdf
Samples shall be taken in a protected place, not exposed to damp air, dust or soot.
The sampling instruments shall be clean and dry, when used.
Precautions shall be taken to protect the samples, the material being sampled, the sampling
device and the containers for samples from adventitious contamination.
The samples shall be placed in clean dry containers. The sample containers shall be of such
size that they are almost completely filled by the sample .
Each container shall be sealed air-tight with a stopper or a suitable closure in such a way that it
will not be possible to open or reseal it without detection after filling, and marked with full details of
sampling, date of sampling, name of the vender and other important details of the consignment.
The samples shall be analysed as soon as possible. If necessary, sample shall be stored in such
a manner that there is no deterioration of the material.
The sampling instruments as well as the sample containers used for taking samples for
assessment of harmful organism shall be clean, dry and sterile.
8
25
12. Nephline Syenite*
Indian Bureau of Mines (IBM), Bangalore, Nagpur, Ajmer
(Under Ministry of Mines) Controller General (I/c), Indian
Bureau of Mines, 2nd Floor, Indira Bhawan, Civil Lines,
NAGPUR 440001 (INDIA). Phone : + 91 712 2560041
Geological Survey of India (GSI), Hyderabad, Chennai,
Kolkata,
Pune,
Faridabad,
Patna,
Bhubaneshwar,
Lucknow, Jammu, Raipur, Vizag., Nagpur, Jaipur (Under
Ministry of Mines) Geological Survey of India, Ministry of
Mines, ShastriBhawan, Dr Rajendra Prasad Road, Central
Secretariat, New Delhi 110001
Sampling Procedure and Time Required for Chemical Analysis:
A representative portion of sample should be drawn from the bulk after thorough mixing,
homogenization, conning and quartering.
The quantity of the sample should be 100 grams.
Size range : ½ inch to 200 mesh.
Sampling Procedure and Time Required for Mineralogical Studies:
A representative portion of sample should be drawn from the bulk after thorough mixing,
homogenization, conning and quartering.
The quantity of the sample should be 500 gms
The size requirement : 1 to 2 inch lumps.
9 26 13. Lime Stone* 14. Quick Lime* 15. Dolomite* 16. Natural Calcite Powder 17. Oliflux 18. Chalk* Indian Bureau of Mines (IBM), Bangalore, Nagpur, Ajmer(Under Ministry of Mines) Indian Bureau of Mines, 2nd Floor, Indira Bhawan, Civil Lines, NAGPUR 440001 (INDIA)
Geological Survey of India (GSI), Hyderabad, Chennai, Kolkata, Pune, Faridabad, Patna, Bhubaneshwar, Lucknow, Jammu, Raipur, Vizag., Nagpur, Jaipur (Under Ministry of Mines) Geological Survey of India, Ministry of Mines, ShastriBhawan, Dr Rajendra Prasad Road, Central Secretariat, New Delhi 110001.
National Metallurgical Laboratory (NML), Jamshedpur,
Chennai (Under Ministry of Science & Technology) CSIR-
NML, Near Tata Steel Gate No-1, Burma Mines,
Jamshedpur, Jharkhand 831007.
IS.1514.1990 quick lime.pdf
Sampling Procedure and Time Required for Chemical Analysis:
A representative portion of sample should be drawn from the bulk after thorough mixing,
homogenization, conning and quartering.
The quantity of the sample should be 100 grams.
Size range : ½ inch to 200 mesh.
Sampling Procedure and Time Required for Mineralogical Studies:
A representative portion of sample should be drawn from the bulk after thorough mixing,
homogenization, conning and quartering.
The quantity of the sample should be 500 gms
The size requirement : 1 to 2 inch lumps
10 27 19. Coking Coal
Central Institute of Mining and Fuel Research (CIMFR), Nagpur, (Under Ministry of Science & Technology) CSIR- CIMFR, Barwa Road, Dhanbad 826015, Jharkhand, INDIA
IS.436.1.1.1964 coal.pdf For the purpose of sampling, the entire quantity of coal in a ship shall be divided into .a suitable number of sub-lots of approximately equal weight as under: NUMBER OF SUB-LOTS/GROSS SAMPLES Weight of the Lot (METRIC TONNISE) No. of sub-lots / gross samples up to 500 2 501 to 1000 3 1001 to 2000 4 2001 to 3000 5 Over 3000 6
A gross sample shall be drawn from each of the sub-lots and shall be kept separately so that there will be as many gross samples as the number of sub-lots into which the lot has been divided. Sampling of coal from ships-shall be carried out, as far as practicable, when coal is in motion. If it is taken on a conveyer, the gross sample shall be collected as per the procedure laid down in 3, If not, the gross samples may be drawn during loading or unloading of the ship. For this purpose, the number of increments to be taken shall be governed by the weight of the gross sample and the weight of increment as specified in Table below for various size groups of coal.
WEIGHT OF GROSS SAMPLE AND NUMBER OF INCREMENTS
Sample
Run-of-
Mine Coal
(23-0 cm)
Coal
Large
(15-5 cm)
Coal
Small (5-
0 cm)
Weight of gross
sample, min
350 kg
175 kg
75 kg
Weight of increment
7 kg
7 kg
5 kg
Number of
increments
50
25
15
20. Steam Coal*
Central Institute of Mining and Fuel Research (CIMFR), Nagpur, (Under Ministry of Science & Technology) CSIR- CIMFR, Barwa Road, Dhanbad 826015, Jharkhand, INDIA Similar to procedure as provided for sampling of “coking coal” (Sl. No. 19.)
-
Solvent C-9*
-
C-9-C-11 Liquid Paraffins*
-
C-14-C-20 N Paraffins*
-
Petroleum Bitumen 60/70*
Indian Institute of Petroleum (IIP), Dehradun (Under Ministry of Science & Technology) CSIR- IIP, Dehradun 248005
IOCL (R&D Centre), Faridabad (Under Ministry of Petroleum) GM (Technology Promotion, Forecasting & Pipeline Research), Indian Oil Corporation Limited, R&D Centre, Sector 13, Faridabad 121007
IOCL/HPCL/BPCL, Mumbai, Chennai, Kochi, Vizag., Kolkata, Kandla (Under Ministry of Petroleum)
Refer to IS.1447.1.2000 petroleum products.pdf for details.
Refer to IS.1447.1.2000 petroleum products.pdf for details.
Refer to IS.1447.1.2000 petroleum products.pdf for details.
IS.1201-1220.1978 bitumen and product.pdf
The sizes of samples to be taken for testing shall be as follows : a) Liquid Materials
- From small containers, cans, drums and barrels - one litre for each separate sample.
- From bulk storage tanks and drums - 5 litres. b) Semi-solid or Solid Materials
- From barrels, drums, cakes and powdered materials in bags 1 to 2 kg for each separate sample.
- From bulk a minimum of 4.5 kg composite or average sample. The number of packages to be selected for sampling from the lot shall be in accordance with col 1 and 2 of Table 1. The sample packages shall be selected at random.
TABLE 1 SCALE OF SAMPLING
NO. OF CONTAINERS/ BAGS IN THE LOT NO. OF CONTAINERS/ BAGS TO BE SELECTED FOR SAMPLING 1 1 2 to 15 2 16 to 50 3 51 to 150 5 151 to 500 8 501 and above 13
Composite sample - From each of the packages selected for sampling a small quantity of material shall be withdrawn with the help of a sampling tube in accordance with the procedure given in below. The quantity so withdrawn from each of the packages shall be fully representative and proportional to its contents. The material withdrawn from all the packages shall be thoroughly mixed together and then the requisite quantity for testing shall be withdrawn. This shall be the composite sample. An identical composite sample if required. may also be made for keeping as reference sample under the joint seals of the purchaser and the seller. If the composite sample passes in respect of all the requirements of the specification the lot may be considered to be in conformity to the requirements of the specification.
A sampling tube of convenient size shall be lowered into the package so that it touches the bottom, and a sample obtained by closing the top end of the tube with the thumb and withdrawing the tube. If the tube contains free water its contents shall be rejected and the tube again lowered into the package to such a depth as to avoid the water. The tube shall then be withdrawn as before and its contents used to rinse the tube and sample container and then discarded. The tube shall next be lowered slowly as far as possible into the contents of the drum or can, without touching the water layer, if present. The tube shall then be closed and withdrawn and the sample allowed to flow gently and without splashing into a sample container.
Semisolid or Solid Materials -
From each of the sample packages from the lot appropriate quantity shall be taken. For this purpose an
appropriate sampling apparatus, aid or device may be used which may involve use of hammer, chisel,
knife or spatula, auger or a scoop. If the material is held in small containers with a bung-hole too small
to introduce the thief, the contents of the container shall be mixed thoroughly by shaking and the
requisite quantity of sample shall be poured out. Care shall be taken to ensure that from each container
the material taken is fully representative and proportional to its contents. The material so taken from
-
Diesel Oil*
-
Waksol 9-11 A Grade*
-
Thinner Off Spec
-
Waste Oil/Sludge Oil/Sludge Water/Bilge Water/Stop Water/ (Furnace/Fuel Oil)*
Central Pollution Control Laboratories (CPCB) (Under Ministry of Environment) Ministry of Environment, Forest & Climate Change, Government of India, Parivesh Bhawan, CBD-cum-Office Complex East Arjun Nagar, DELHI - 110032 each of the sample containers shall be thoroughly mixed together or melted together if necessary to form a combined mass of material from which a suitable sample for testing shall be taken. This shall be called the composite sample. If required a similar composite sample may be taken for purpose of preservation for reference under the joint seals of purchaser and the seller. The composite sample shall be required to pass all the specified requirements in order to declare a lot to be in conformity to the requirements of this specification.
Refer to IS.1447.1.2000 petroleum products.pdf for details.
Refer to IS.1447.1.2000 petroleum products.pdf for details.
Refer to IS.1447.1.2000 petroleum products.pdf for details.
Procedure as prescribed in “Manual on Sampling, Analysis and Characterisation of hazardous waste”
issued by Central Pollution Control Board.
11
28
29. Nickel-Cobalt Mixed
Hydroxide
Indian
Institute
of
Chemical
Technology
(IICT),
Hyderabad, (Under Ministry of Science & Technology)
CSIR-Indian Institute of Chemical Technology, Uppal
Road, Tarnaka, Hyderabad - 500 007, Telangana State,
India
National Chemical Laboratory (NCL), Pune (Under Ministry of Science & Technology) CSIR-NCL, Dr.HomiBhabha Road, Pune 411008, India.
12 29 30. Oxo Erythronolide A- 11,12 Carbamate 31. Acid Buff 32. Rynaxypyr Tech. 33. Linear Alpha Olefins 34. PCTP-B 35. EC100 36. 6-Nitro Diazo 2-Naphthol Acid 37. Exxsol Hexane Fluid 38. Neo Pentyl Glycol Flakes 39. PTA 40. Chromatographic Chemicals 41. isoOctanol
Indian Institute of Chemical Technology (IICT), Hyderabad, (Under Ministry of Science & Technology) CSIR-Indian Institute of Chemical Technology, Uppal Road, Tarnaka, Hyderabad - 500 007, Telangana State, India
-
Methyl ChloroFormate
-
Dodine 98% Tech Central Insecticide Laboratory (CIL), Faridabad (Under Ministry of Agriculture) Directorate of Plant Protection, Quarantine and Storage, Ministry of Agriculture, NH IV, Faridabad, Haryana, India 121001
IS.10946.1996 pesticides.pdf
Liquid Samples :-
Generally the product should be homogenized by inverting the pack and rolling. Then open the lid or
cap and for withdrawing a sample, the tube is first closed at the top with the thumb or a stopper and
lowered until the desired depth is reached. It is then opened and the material is allowed to fill naturally.
Finally the tube is closed by thumb or a stopper and sample is transferred to container.
Viscous Liquids and Meltable Solids:-
Provided it is known that the product to be sampled does not undergo decomposition during melting,
warm the material until sufficiently mobile or completely molten. Following procedure may be adopted
for sampling of such products. Products packed in drums would be heated to a temperature gradient of
40 to 50°C using a suitable water bath for a period about 4 to 6 hours to ensure complete liquification.
Thereafter, immediately the drums will be rolled for about 15 minutes to completely homogenize the
contents. Samples are then drawn using procedure given above.
Solids:-
Insert the tube thief (bag trier) with the slots closed into the container until the point rests on the bottom.
Turn the handle to open the slots and allow the material to fill the thief. Close the slots, withdraw the
thief and place a plastic bag around the thief. Using thread close the plastic bag around the top of the
thief and allow the contents to flow into the bag. Repeat the procedure at different sampling positions in
the container until sufficient sample is obtained.
13
30
44. Propofol Injection
Indian Pharmacopeia Commission (IPC), Ghaziabad (Under Ministry of Health & Family Welfare) O/o The Secretary-cum-Scientific Director, IPC, Ministry of Health & Family Welfare, Govt. of India, Sector-23, Raj Nagar, Ghaziabad 201002. Tel.:0120-2783400, 2783401,
-
Heparin Injection
-
Finasteride Tab
-
Montelucast Sod Tab
-
FE-3 Hydroxylpoloymontex Complex
-
Omeprazole Pellets
-
Lansoprazole Pellet
-
Fexofenadine HCl
-
Esomeprazole di hydrate
-
Coba-1
-
Cyte-7
-
Carvedilol
-
Sparfloxacine
-
Tamsulosin HCl Pellet
-
Norfloxacine
-
Dextromethorphan
-
Sildenafil Citrate
-
Telmeisartany
-
Ciprofloxacine HCl
-
Itraconazole Pellet
-
Panto Prazole Sodium
-
Divalproex Sodium
-
Toltuosin Tastrater Pellet
-
CTAC (DFA-SCI)
-
Fluoxetine HCl
-
CAINL-5 2783392, FAX: 0120-2783311, E-mail: ipclab@vsnl.net, Website: www.ipc.gov.in
Central Drug Testing Laboratory (CDTL), Chandigarh, Chennai, Hyderabad, Mumbai (Under Ministry of Health & Family Welfare) Central Drugs Standard Control Organization (CDTL and CDL), Directorate General of Health Services, Ministry of Health and Family Welfare, Government of India, FDA Bhavan, ITO, Kotla Road, New Delhi 110002. Phone:91-11-23216367(CDSCO)/ 23236975, Fax: 91-11-23236973, E-mail:- dci@nic.in, 91- (522)-2771941
Central Drug Laboratory (CDL), Kolkata (Under Ministry of Health & Family Welfare) Central Drugs Standard Control Organization (CDTL and CDL), Directorate General of Health Services, Ministry of Health and Family Welfare, Government of India, FDA Bhavan, ITO, Kotla Road, New Delhi 110002. Phone: 91-11- 23216367(CDSCO)/ 23236975, Fax: 91-11-23236973, E- mail:- dci@nic.in, 91-(522)- 2771941
-
CMPY-8
-
CETE-9
-
CHDR-2, 3
-
CYRR-3
-
Casigel TMFG S-4 14 31
-
Vegetable Liquid Fertilizer* Central Fertilizer Quality Control Unit (CFQCTI), Faridabad, Mumbai, Chennai, Kalyani (WB) (Under Ministry of Agriculture) Director, CFQCTI, N.H. IV, Faridabad 121001, Haryana (Under the Ministry of Agriculture and Farmers Welfare, Govt. of India) Tel: 0129- 2414712, Email: cfqcti@nic.in IS.6092.1.1985 fertilizer.pdf
Process of sampling shall not unnecessarily be exposed to weather. The sampling equipments shall be clean, dry and should not be a source of contamination.
The material being sampled, the sampling equipments and the containers for samples shall be protected from adventitious contamination. Metallic containers must be avoided. To draw a representative sample from bagged fertilizer, the contents of each container selected for sampling shall be mixed as thoroughly as possible by suitable means.
The sample immediately after being drawn shall be placed in wide-mouthed clean, dry and air- tight glass or other suitable containers for example PVC or polyethylene, which must not react with the sample. The sample containers shall be of such a size that they are almost completely filled by the sample (but not tightly packed).
Each sample container shall be sealed air-tight after filling and marked with full details of sampling, the date of sampling and other important particulars of the consignment.
For micronutrients and impurities, the equipments made from materials like plastic, aluminium, and wood shall be used. Stainless steel equipments if used must be of the best quality free from any scratches.
Samples shall be stored in shade under dry weather conditions. -
HYT (Organic Fertilizer)* National Centre of Organic Farming (NCOF), Ghaziabad (Under Ministry of Agriculture) Director, NCOF, Department of Agriculture, Cooperation and Farmers Welfare, Ministry of Agriculture and Farmers Welfare, Government of India, Sector 19, Hapur Road, Kamla Nehru Nagar, GHAZIABAD 201002, Uttar Pradesh Tel: 0120-2764906, 2764212; Fax:0120-2764901, Web: http://ncof.dacnet.nic.in, Email: nbdc@nic.in IS.6092.1.1985 fertilizer.pdf
Process of sampling shall not unnecessarily be exposed to weather. The sampling equipments shall be clean, dry and should not be a source of contamination.
The material being sampled, the sampling equipments and the containers for samples shall be protected from adventitious contamination. Metallic containers must be avoided. To draw a representative sample from bagged fertilizer, the contents of each container selected for sampling shall be mixed as thoroughly as possible by suitable means.
The sample immediately after being drawn shall be placed in wide-mouthed clean, dry and air- tight glass or other suitable containers for example PVC or polyethylene, which must not react with the sample. The sample containers shall be of such a size that they are almost completely filled by the sample (but not tightly packed).
Each sample container shall be sealed air-tight after filling and marked with full details of
sampling, the date of sampling and other important particulars of the consignment.
For micronutrients and impurities, the equipments made from materials like plastic, aluminium,
and wood shall be used. Stainless steel equipments if used must be of the best quality free from any
scratches.
Samples shall be stored in shade under dry weather conditions.
Sampling from Bagged Fertilizers
a.
Place the bag in a horizontal position, then roll or flip over three or more times.
b.
Open the bag by cutting a couple of stitches at one corner and insert the probe so that it
extends diagonally from corner to corner with slot down. It should not pierce through the bag. Turn it
one half turn to bring the slot up, jar bag slightly to fill the probe, and remove carefully so as not to drag
material out of it with the bag edges.
c.
Empty entire contents of each probe into a suitable container. Take one core per bag. Combine
contents of all probes of the lot being sampled and place in a container with moisture seal. Label the
contents before another lot is sampled.
d.
In case the material in the bag is in a caked condition the bag is dropped several times from a
height about 1 metre till lumps are all broken up before sampling with the probe. Mild strokes with a
wooden hammer may be helpful. In cases of extreme difficulty, the bag may be opened out and a sample
taken either by riffling or by coning and quartering.
e.
A double tube probe as prescribed under sampling of bulk material can also be used for
sampling bags.
15
32
77. SO Dyes (Vat Red)
78. Direct Fast Black B (Jade
Black 75%)
79. SO Dyes Stuff Ponceau-4-
R
80. Acryzal Red GBR
81. Coractive Yellow
82. Syn. Org. Dye Stuff Acid
Black
83. Syn. Dye Stuff
84. Acid Green 20
85. SO Dye Yellow HS
86. Idlol FD&C Red No.
40AL
Lake
87. Monarus Red
88. Sunset Yellow
89. Master Batch
Indian
Institute
of
Chemical
Technology
(IICT),
Hyderabad (Under Ministry of Science & Technology)
CSIR-Indian Institute of Chemical Technology, Uppal
Road, Tarnaka, Hyderabad - 500 007, Telangana State,
India
EPABX:
+91-40-
27191234,
Website:
www.iictindia.org
IS.5299.2001 dye intermediate.pdf , IS.8883.1.2005 chemical and product.pdf
Sample shall not be taken at a place exposed to such weather as would affect basic change in its
physico-chemical characteristics.
The sample container shall be properly labelled with necessary information such as: a) Name of
the sample; b) Source of sample; c) Date/Time of sample; d) Drawn by; e) In the presence ofi and ~
Special precautions, if any.
Use of appropriate personal protective equipment (PPE) are strongly recommended during
sampling.
Never smell the sample or taste by tongue.
Proper sampling tools/containers need to be used.
Adhere to the local regulatory guidelines, if any during the sampling.
The sample container shall be of such a size that they ahnost but not, completely filled by the
sample. They shall be made of the material which shall not react with the contents of the sample. In
other words the sample shall not change its. physiochemical characteristics in the container used.
To draw a representative sample, the contents of each container selected for sampling shall be
mixed thoroughly by suitable means or appropriate procedures.
Precautions shall be taken to protect the samples, the sampling instrument and the container of
the sample from adventitious contaminations.
Once the container is opened there is a risk of deterioration of contents due to the presence of
various factors, such as air, light, moisture, excessive temperature, etc. Care has to be taken to avoid the
risk of polymerization, formation of peroxides in the sample by undue exposure to air or strong light.
To obtain samples that are representative in the statistical sense, one must consider such factors
as physical form, uniformity, type and number of containers. All these factors influence the choice of
method for performing the sampling operation, as well as the number and storage of the required
samples.
16
35
90. Modified Starch*
Central Food Technology Research Institute (CFTRI),
Mysore (Under Ministry of Science & Technology)
Director, CSIR-CFTRI, Cheluvamba, Mansion Opp.
Railway Museum, Mysuru, Karnataka 570020. Website:
www.cftri.com
Central Drug Research Institute (CDRI), Lucknow (Under Ministry of Science & Technology) Director, CSIR- Central Drug Research Institute, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow, Uttar Pradesh 226031. Volume_IV_Ensuring_FSS_Food_Sampling_Analysis.pdf IS.4662.1977 starch.pdf (a) Sampling shall be carried out in such a manner as to protect the sample, the sampling instruments and the containers in which the samples are placed from adventitious contamination, such as rain and dust. (b) Material adhering to the outside of the sampling instruments shall be removed before the contents are discharged. (c) A sample shall be drawn from each container to be sampled with the sampling instrument which is inserted through a convenient opening in such a manner as to sample the entire depth of the contents. (d) All samples from the same consignment shall be put into a clean and dry receptacle, preferably of stainless steel. The contents of the receptacle shall be thoroughly mixed and the required sample drawn into a clean and dry sample container. (e) The sample container shall be closed, leaving sufficient air space at the top for expansion. On the other hand this space shall not be too large, as air exerts detrimental action. (f) All samples shall be protected from light and heat, and kept in a cool place. 17 38 91. Micro Nutrients*
Indian Institute of Chemical Technology (IICT), Hyderabad (Under Ministry of Science & Technology) CSIR-Indian Institute of Chemical Technology, Uppal Road, Tarnaka, Hyderabad - 500 007, Telangana State, India EPABX: +91-40- 27191234, Website: www.iictindia.org
Central Fertilizer Quality Control Unit (CFQCTI), Faridabad, Mumbai, Chennai, Kalyani (WB) (Under Ministry of Agriculture) Director, CFQCTI, N.H. IV, Faridabad 121001, Haryana (Under the Ministry of Agriculture and Farmers Welfare, Govt. of India) Tel: 0129- 2414712, Email: cfqcti@nic.in
Similar to procedure as provided for sampling of “Fertilizers” (Sl. No. 75)
-
Mould Inhibitor
-
Electronic Cigarette Liquid Central Insecticide Laboratory (CIL), Faridabad (Under Ministry of Agriculture) Directorate of Plant Protection, Quarantine and Storage, Ministry of Agriculture, NH IV, Faridabad, Haryana, India 121001 Tel: 0129-2413014, Email: cilfbd@nic.in
Indian Institute of Chemical Technology (IICT), Hyderabad (Under Ministry of Science & Technology) CSIR-Indian Institute of Chemical Technology, Uppal Road, Tarnaka, Hyderabad - 500 007, Telangana State, India EPABX: +91-40- 27191234, Website: www.iictindia.org Similar to procedure as provided for sampling of “Dodine” (Sl. No. 43)
18
39
94. PVC Compound*
95. PVC Off Grade*
96. Polyethylene Compounds*
97. Hostalen
98. Non Woven Tow Puff
Sheets
99. Insole Sheet*
100. Polyol Syncopol*
101. Exter C1 Z1270
(Polyol)*
102. LDPE Reprocessed
103. Recycled LDPE
104. Vista Maxx 6502
(Polypropylene Copolymer)
105. Hydroxyethyl Methyl
Cellulose*
106. Sodium Carboxy Methyl
Cellulose*
107. HDPE Reprocessed
108. HDPE Off Grade*
109. HDPE Recycled
110. Floor Sweeping Granules
HDPE*
111. PE Sweeping Granules*
Central Institute of Plastic Engineering Technology
(CIPET),
Lucknow,
Chennai,
Hyderabad,
Jaipur,
Midnapur (WB) (Under Ministry of Chemicals &
Fertilizers) CIPET, T.V.K. Industrial Guindy, Chennai
600032.
(Under
Department
of
Chemicals
&
Petrochemicals, Ministry of Chemicals & Fertilizers)
Phone:
+91-44-22253040 (Direct),
+91-44-22254780
(Office),
Fax
No.:
+91-44-
222547,
Email:
cipetdgoffice@gmail.com
IS.9766.1992j pvc compound.pdf
Samples shall not be taken in an exposed place.
The sampling instrument shall be made of stainless steel or any other suitable material on
which the material shall have no action. The instrument shall be clean and dry.
Precautions shall be taken to protect the samples, the material being sampled, the sampling
instrument and the containers for samples-from adventitious contamination.
The samples shall be placed ina suitable, clean, dry, air-tight metal or glass containers on which
the material has no action. The sample containers shall be of such a size that they are almost completely
filled by the sample.
Each sample container shall be sealed air-tight with a stopper after filling and marked with full
details of sampling, such as, the date of sampling, the month and year of manufacture of the material, etc
Samples shall be stored in such a manner that the temperature of the material does not vary
unduly from the normal temperature.
19
40
112. Rubber Compound Grade
C
113. Recycled Rubber Mat
The Rubber Research Institute of India, Kottayam, (Under
Ministry of Commerce & Industry) Ministry of Commerce
and Industry, Govt. of India, Rubber Board PO, Kottayam
Square Tiles 114. ABS 4124 90/04 Reprocessed 686009, Kerala, India Ph: 91-481-2353311-20 (10 lines), Fax: 91-481-2353327, Contact General: info@rubberboard.org.in 20 44 115. Wood Powder Forest Research Institute (FRI), Dehradun Forest Research Institute (Deemed) University, Kaula Garh Road, PO. I.P.E., Dehradun 248195 Tel: 0135-2224439, 0135- 2751826, Email:enquires@fridu.edu.in
Central Wood Testing Laboratory, Rubber Board, Kottayam (Under Ministry of Commerce & Industry) Ministry of Commerce and Industry, Govt. of India, Rubber Board PO, Kottayam 686009, Kerala, India Ph: 91- 481-2353311-20 (10 lines), Fax: 91-481-2353327, Contact General: info@rubberboard.org.in 21 47 116. Rejected Mix Stock
- Soft Wood/ Mechanical/ Kraft/ Aspen/ BCTMP Pulp Central Paper & Pulp Research Institute (CPPRI), Saharnpur (UP) (Under Ministry of Commerce and Industry) Director, CPPRI, Post Box 174, Paper Mill Road, Himmat Nagar, Saharanpur 247001, India Phone: (0132) 2714050, 2714061, 2714062, 2714059, Fax: (0132) 2714052, Email: director@cppri.org.in, info@cppri.org.in.
Same as above.
Forest Research Institute (FRI), Dehradun Forest Research
Institute (Deemed) University, Kaula Garh Road, PO.
I.P.E., Dehradun 248195 Tel: 0135-2224439, 0135-
2751826, Email: enquires@fridu.edu.in
IS.1060.1.1966 paper and products.pdf
Care shall be taken to select samples or portions of rolls or reels that are not damaged. It is
good practice to discard a few outermost sheets of reams or the first few layers of roll or reel to be sure
of obtaining representative samples.
Where portions have to be taken by cutting, they shall be cut across the full width of the
undamaged layers.
Samples shall not be taken from an exposed place.
Samples shall be kept flat, free from wrinkles and folds. They shall be protected from exposure
to heat, direct sunlight, liquids, varying humidity conditions as well as any other harmful influences.
Samples shall be handled as little as possible and contact with sweated hands shall be strictly
avoided. Contact with hands may quite appreciably affect the chemical, physical, optical, surface or
other characteristics.
Samples to be tested for moisture shall be placed immediately after sampling in an air-tight
container.
Test of strength characteristics shall not be carried out with portions bearing water-marks,
creases or any visible imperfections.
Each specimen shall be provided with identification mark,. This being necessary to ensure its
recognition beyond all doubts. These marks should be indelible and may be limited to the number of the
sampling report and the signature of the sampler. They should be in one corner and as small as possible.
22
48
118. Gypsum Board Paper
119. PCTP-B
120. PTG Paper
121. Uncoated Paper Board
Insole Sheet
122. Electrical Grade
Industrial Press Board
123. Chemical Counter Sheet
Non Woven Insole Board
124. Cellulose Insole Sheet
Central Paper & Pulp Research Institute (CPPRI),
Saharnpur (UP) (Under Ministry of Commerce and
Industry) Director, CPPRI, Post Box 174, Paper Mill Road,
Himmat Nagar, Saharanpur 247001, India Phone: (0132)
2714050, 2714061, 2714062, 2714059, Fax: (0132)
2714052, Email: director@cppri.org.in, info@cppri.org.in
IS.1060.1.1966 paper and products.pdf
Care shall be taken to select samples or portions of rolls or reels that are not damaged. It is
good practice to discard a few outermost sheets of reams or the first few layers of roll or reel to be sure
of obtaining representative samples.
Where portions have to be taken by cutting, they shall be cut across the full width of the
undamaged layers.
Samples shall not be taken from an exposed place.
Samples shall be kept flat, free from wrinkles and folds. They shall be protected from exposure
to heat, direct sunlight, liquids, varying humidity conditions as well as any other harmful influences.
Samples shall be handled as little as possible and contact with sweated hands shall be strictly
avoided. Contact with hands may quite appreciably affect the chemical, physical, optical, surface or
other characteristics.
Samples to be tested for moisture shall be placed immediately after sampling in an air-tight
container.
Test of strength characteristics shall not be carried out with portions bearing water-marks,
creases or any visible imperfections.
Each specimen shall be provided with identification mark,. This being necessary to ensure its
recognition beyond all doubts. These marks should be indelible and may be limited to the number of the
sampling report and the signature of the sampler. They should be in one corner and as small as possible.
23
55
125. Recycled Polyester
Staple Fiber
- Polyester Staple Fiber* Textile Committee, New Delhi, Mumbai, Chennai, Kolkata, Jaipur (Under Ministry of Textiles) Secretary, Textiles Committee, Ministry of Textiles, Government of India, P Balu Road, Prabhadevi, Mumbai 400025 E-Mail: Secy.tc@nic.in, secytc@gmail.com, Phone: +91-22- 66527507, 66527506, Fax: +91-22-66527509
Central Institute of Plastic Engineering Technology
(CIPET),
Lucknow,
Chennai,
Hyderabad,
Jaipur,
Midnapur (WB) (Under Ministry of Chemicals &
Fertilizers) CIPET, T.V.K. Industrial Guindy, Chennai
600032.
(Under
Department
of
Chemicals
&
Petrochemicals, Ministry of Chemicals & Fertilizers)
Phone:
+91-44-22253040 (Direct),
+91-44-22254780
(Office), Fax No.: +91-44-
222547, Email: cipetdgoffice@gmail.com
IS.4807.1968 manmade staple fibre.pdf
A bale may be regarded as consisting of two zones ( inner and outer zones ) of equal volumes, the edges
of the inner zone of the bale being equal to 80 percent of the corresponding edges of the bales. Draw
from the outer zone 5 sub-samples, each weighing about 20 to 25 g, in such a way that each sub-sample
is taken from a different face of the bale and at random within the face. Cut the inner zone of the bale by
two imaginary planes in random positions— one above the centre of the bale and the other below it.
Draw two sub-samples each from A and C and the fifth sub-sample from B. In this way, collect from
each bale nearly 200 to 250 g of fibres. Mix the fibres uniformly, collected from all the bales
constituting the bulk sample. Take about 1 000 g from well-mixed fibres; this shall constitute the gross
sample.
Divide the gross sample into 16 equal parts. Take a small quantity of fibres from each of the sixteen
parts so as to make a total of 50 g approximately. This should constitute the test sample.
The number of bales to be chosen at random from a lot shall be as given below. All the bales so selected
shall be taken together to constitute the bulk sample:
No. of bales in a Lot
No. of bales to be chosen
Up to 8
All
9 to 25
8
26 to 50
13
51 to 100
20
101 and above
25
24 68 127. Brake Lining Central Glass & Ceramic Research Institute (CGCRI), Kolkata (Under Ministry of Science & Technology) CSIR- CGCRI, 196, Raja S.C. Mullick Road, Kolkata 700032, West Bengal, India Fax/E-mail: Director’s Office: +91 33 24730957/ dir_office@cgcri.res.in Administration: +91 33 24736082/cgcriao@cgcri.res.in Purchase Section: +91 33 24838085/purchase@cgcri.res.in Testing & Characterization Cell: +91 3324837339/ testing_cell@cgcri.res.in
National Test House (NTH), Kolkata, Ghaziabad, Jaipur, Mumbai, Chennai (Under Ministry of Consumer Affairs) O/o The Director General, NTH, Block - CP, Sector - V, Salt Lake City, Kolkata 700091 Tel. No.: +91 33 23673870 (DG), +91 33 23673872 (AO), Fax No.: +91 33 23673868/69, E-mail: dgnth-wb@nic.in 25 69 128. Valorzac (Refractory Cullet)
- Zircoval Dn (Refractory Cullet) Central Glass & Ceramic Research Institute (CGCRI), Kolkata (Under Ministry of Science & Technology) CSIR- CGCRI, 196, Raja S.C. Mullick Road, Kolkata 700032, West Bengal, India Fax/E-mail: Director’s Office: +91 33 24730957/dir_office@cgcri.res.in Administration: +91 33 24736082/cgcriao@cgcri.res.in Purchase Section: +91 33 24838085/purchase@cgcri.res.in Testing & Characterization Cell: +91 3324837339 /testing_cell@cgcri.res.in 26 70
- Low e-glass
- Glass Bead*
- Crystallized Glass Panel
- Super Nano Glass Slab As above. 27 72
- Charged Chrome
- Metal Scrap National Metallurgical Laboratory (NML), Jamshedpur, Chennai, Chennai (Under Ministry of Science & Technology) Director, CSIR- NML, Near Tata Steel Gate No-1, Burma Mines, Jamshedpur, Jharkhand 831007. Tel: +91-657-2345000-001, 2345028, 2345205, Fax: 91-6572345213, 2345153, E-Mail: director@nmlindia.org, Website: http://www.nmlindia.org
- Indicate those products which are being tested at JNCH Customs Laboratory, Nhava Sheva itself.
Verbatim extracted text (OCR/PDF). Older scans and tables may show extraction artifacts — verify against the original for anything you act on.